Electrochemical Behavior and Determination of Fluconazole

Abstracts

The electrochemical behavior of fluconazole showed an irreversible oxidation process, with the electrochemical - chemical mechanism being highly dependent on the electrode material. Adsorption of reagent at positive applied potential was observed at Pt electrode while preferential adsorption of the oxidation products was observed at Glassy Carbon surfaces. In pH below 7.0, the anodic current process was intensively decreased. At carbon paste electrode, the fluconazole oxidation current, recorded in phosphate buffer solution (pH 8.0), changed linearly with the fluconazole concentration, Ipa = 5.7×10-5 (mA) × 0.052 [Fluconazol] (μg mL-1), in the range of 48.0 to 250.0 μg mL-1. The detection limit obtained was 6.3 μg mL-1.

fluconazole; electrochemical behavior; voltammetry; electrodic material


O comportamento eletroquímico do fluconazol demonstrou oxidação irreversível com mecanismos eletroquímicos-químicos dependentes do material eletródico. Em eletrodos de Pt observou-se adsorção do reagente sob a aplicação de potenciais positivos, enquanto adsorção preferencial dos produtos foi observada em eletrodo de carbono vítreo. Em valores de pH inferiores a 7,0, a corrente do processo anódico é intensamente diminuída. Em eletrodo de pasta de carbono e tampão fosfato, pH 8,0, a corrente de oxidação variou linearmente com a concentração de fluconazol em solução, Ipa = 5,7×10-5 (mA) × 0,052 [Fluconazol] (μg mL-1), no intervalo de 48,0 a 250,0 μg mL-1. O limite de detecção obtido foi 6,3 μg mL-1.


ARTICLE

Electrochemical Behavior and Determination of Fluconazole

Éric de S. GilI, * * e-mail: ericsgil@gmail.com ; Diogo D. CordeiroI; Ana E. B. MatiasI; Sílvia H. P. SerranoII

IFaculdade de Farmácia, Universidade Federal de Goiás, Av. Universitária com 1º Avenida s/n, Setor Universitário, 74605-220 Goiânia-GO, Brazil

IIInstituto de Química, Departamento de Química Fundamental, Universidade de São Paulo, Avenida Prof. Lineu Prestes, 748, Bloco 2 superior, 05508-900 São Paulo-SP, Brazil

ABSTRACT

The electrochemical behavior of fluconazole showed an irreversible oxidation process, with the electrochemical - chemical mechanism being highly dependent on the electrode material. Adsorption of reagent at positive applied potential was observed at Pt electrode while preferential adsorption of the oxidation products was observed at Glassy Carbon surfaces. In pH below 7.0, the anodic current process was intensively decreased. At carbon paste electrode, the fluconazole oxidation current, recorded in phosphate buffer solution (pH 8.0), changed linearly with the fluconazole concentration, Ipa = 5.7×10-5 (mA) × 0.052 [Fluconazol] (μg mL-1), in the range of 48.0 to 250.0 μg mL-1. The detection limit obtained was 6.3 μg mL-1.

Keywords: fluconazole, electrochemical behavior, voltammetry, electrodic material

RESUMO

O comportamento eletroquímico do fluconazol demonstrou oxidação irreversível com mecanismos eletroquímicos-químicos dependentes do material eletródico. Em eletrodos de Pt observou-se adsorção do reagente sob a aplicação de potenciais positivos, enquanto adsorção preferencial dos produtos foi observada em eletrodo de carbono vítreo. Em valores de pH inferiores a 7,0, a corrente do processo anódico é intensamente diminuída. Em eletrodo de pasta de carbono e tampão fosfato, pH 8,0, a corrente de oxidação variou linearmente com a concentração de fluconazol em solução,

Ipa = 5,7×10-5 (mA) × 0,052 [Fluconazol] (μg mL-1), no intervalo de 48,0 a 250,0 μg mL-1. O limite de detecção obtido foi 6,3 μg mL-1.

Introduction

Fluconazole is a fluorine-substituted bis-triazole which is commonly used as an anti-fungal drug to treat superficial and systemic mycoses,1 whose structure is depicted in Figure 1.


Various analytical methods have been developed for the determination of fluconazole, most of them including spectrometric2,3 and chromatographic methods.4-6 The presence of electroactive groups in fluconazole molecule makes it an interesting candidate for electroanalytical methods. Furthermore, while there are already some publications of imidazole analogues in the electrochemical area,7-10 there is no electrochemical studies extended to fluconazole and other triazoles antifungals available in the literature.

Electrochemistry has many advantages which turns it a good option for pharmaceutical and bioanalysis applications. These techniques offer a wide dynamic range and require only small sample volumes, often in the microliter range, that coupled with the low detection limits, allows analysis on subpicogram amounts of analyte. Also, the selectivity of electrochemical detection in complex samples is excellent, because fewer electroactive interferents are often encountered than spectroscopic interferents.11 Considering the levels of fluconazole in many clinical samples (e.g. urine, blood, faeces, breast milk, saliva, cerebrospinal fluid and ocular fluids), as well the fact of 90% is excreted unchanged in the urine and 10% in the faeces,1,12 the higher sensitivity can be useful to detect the unchanged form of fluconazole in these matrices.

The aim of the present work is to study the redox behaviour of fluconazole in aqueous solutions at platinum (Pt) and carbon (glassy carbon and carbon paste) electrodes, using several voltammetric techniques and, also, develop sensitive electroanalytical procedures for the direct determination of fluconazole.

Experimental

Apparatus

All voltammetric curves were obtained using a μAutolab type III potentiostat from Eco Chemie (Utrecht, Netherlands) and GPES software (Eco Chemie). The voltammetric system was composed by a 10 mL electrolytic cell linked by a three electrode system. A calomelane (SCE) was used as reference electrode and a platinum wire was used as auxiliary electrode, while the work electrodes were of platinum (Pt, Ø 0.2 mm); glassy carbon (GC, Ø 2 mm) or carbon paste electrode (CP, Ø 2 mm).

Chemicals, solutions and sample preparation

All solutions were prepared from analytical grade chemicals with de-ionized water from Milli Q system (Millipore, Bedford, mA, USA). Phosphate buffer (0.1 mol L-1, pH 4.0-8.5) and 0.1 mol L-1 KCl pH 8,0 were used as supporting electrolyte. The pH was adjusted with 0.1 mol L-1 NaOH or HCl solutions.

The standard solution was prepared by dissolving fluconazole in NaOH 0.1 mol L-1 in order to reach the final fluconazole concentration of 0.2%. The working solution was prepared by suitable dilution in de-ionized water in order to reach 0.02% solution. The standard of fluconazole was purchased from Brazilian Pharmacopoeia.

The standard addition method was then applied, adding successive aliquots of 50 μL of the 0.02% solution in the 10 mL cell.

Results and Discussion

Fluconazole exhibits a clearly pH dependent oxidation process, which is entirely suppressed at pH 4.0 (Figure 2). At a glassy carbon electrode, the anodic process began at 0.8 V and extend to higher potentials (above 1.1 V), probably involving the oxidation of the N- in the azo groups. This supposition is supported by the fact that triazoles can undergo oxidation through the loss of an electron of triazolic ring, producing a radical-cation, which suffer further dimerization step to form a bis-compound.13


The influence of pH on fluconazole oxidation showed to be very similar to some thiotriazoles. Previous report,14 using DPV, showed that peak potential for the anodic process (Ep,a) of thiotriazoles shift to less positive value with increasing pH and is pH independent above of pH 8.0, while the peak current (Ip,a) increases from pH 8.0. Similar effect was also observed with fluconazole, when the pH was changed from 8.0 to 8.5, Figure 3.


The electrodic material has great influence over the oxidation process, being more intense for larger superficial area. The Figure 4 shows the voltammograms obtained at the same conditions with three different electrodes.


It was also observed for glassy carbon (GC) electrode by cyclic voltammetry that after successive cycles, the fluconazole is accumulated over the surface increasing the current levels, which stabilize at the saturation point, which occurs only after 15 cycles (Figure 5). This fact was confirmed after cleaning the electrode surface and registered of 15 consecutive voltammograms in phosphate buffer, pH 8.0, without fluconazole. As can been seen, the electrode surface is not modified by cycling on the supporting electrolyte.


This adsorptive behavior is consistent with the pre pre-concentration of ketoconazole at a mercury electrode on a open circuit,7 but in our experimental conditions, no adsorption, on a open circuit, was observed at glassy carbon electrode and, it was very slight at platinum electrode, even after 5 min of immersion in 0.2% fluconazole solution.15 It is an indicative that the adsorption could be attributed to the adsorption of the fluconazole oxidation products rather than fluconazole, since that the electrode surface is not modified by action of the supporting electrode at higher applied potentials.

The stabilization of current levels improves a lot, when the experiments are carried on carbon paste (CP) electrode. Indeed, even after successive experiments, the voltammograms profile remains stable (Figure 6).


When the experiments were carried on platinum (Pt) work electrode, a great shift to lower potential was observed for the anodic peak, but just for the first scan (Figure 7).


Furthermore, the decreasing of the current level is continuous even after 10 or more cycles and, after cleaning procedure the electrode surface (mechanical polishing and use of ultrasound for 5 min in water), the current level obtained in the first scan of Figure 7 cannot be reproduced, Figure 8.


These experimental results can be explained taking in account the adsorption of the fluconazole reaction products and the ability of the "semiflexible" organic ligand combine to metal centre by one or two of its 1,2,4-triazole groups resulting in a passivation of the electrode surface.16 The same behavior can be checked in other triazoles, since studies suggest that these molecules could complex with metals (like copper and gold) in electrodes surface.13,17 Indeed, much attention have been given to the use of azoles to prevent the corrosion process, by surface protection (adsorption and film formation).17-19

The ability of fluconazole to adsorb strongly on the electrode surface may compromise some analytical parameters such as sensitivity, linearity and reproducibility in na electroanalytical methodology. Therefore, to obtain a calibration curve for analytical purposes, the utilization of platinum or a glassy carbon working electrodes require constant superficial regeneration, which can be eliminated by using carbon paste modified electrodes. At this material no adsorption effects were observed and, this different behavior is probably associated with the adsorption mode of the oxidation product, which depends of the electrode material, principally in the case of flexible molecules such as fluconazole. The calibration curve, obtained using carbon paste modified electrode and DPV, is presented on Figure 9.


When the fluconazole adsorption on the electrode surface is controlled, the electroanalytical method showed to be a possible alternative in the determination of this drug, since it was observed a low detection limit (estimated as 6.3 μg mL-1), good linearity (R = 0.9989) in the range from 48.0 to 250.0 μg mL-1 and relative standard deviation (RSD) of 3.1% (n = 3). The regression equation was Ipa = 5.7×10-5 (mA) × 0.052 [Fluconazol] (μg mL-1). The fluconazole determination were carried in pharmaceutical capsules, obtained a recovery of 98% (RSD 5.8%).

However, the reproducibility of the proposed method was slight lower as compared with the spectrophotometric (RSD < 3%),20-22 while the sensitivity was similar to those reported for chromatographic methods,5,6,23 which is in the order of μg mL-1. No more comparison of results is possible since that there is no electroanalytical method described for fluconazole determination and, therefore the simplicity, rapidity and low cost of the proposed method should be taking in account.

Conclusions

Fluconazole showed electrochemical behavior consistent with other triazoles related in the literature, with the oxidation process being pH dependent and more effective in alkaline medium. Adsorption of the fluconazole oxidation products were observed at glassy carbon and platinum electrodes. In the last case, adsorption of the reagent cannot be discarded since that, as a flexible ligand, fluconazole is a good metal complexing agent and can promote decreasing of current levels at platinum working electrode. Poisoning of the electrode surface was not observed at carbon paste surfaces, which shows the importance of the electrode material in the global process. The linear response range at carbon paste electrode was from 48.0 to 250.0 μg mL-1, with a detection limit of 6.3 μg mL-1.

Submitted: June 18, 2010

Published online: January 25, 2011

FAPESP has sponsored the publication of this article.

  • 1. Hardman, J. G.; Gilman, A. G.; Limbird, L. E., eds.; Goodman and Gilman's The Pharmacological Basis of Therapeutics, 10th ed., Mc-Graw Hill: New York, NY, 2005.
  • 2. Otay, O.; Selçk, F.; Anal. Lett. 1996, 29, 2163.
  • 3. Göger, N. G.; Abou-Enein, H. Y.; Anal. Lett. 2001, 34, 2089.
  • 4. Beijnen, J. H.; Meenhorst, P. L.; Gijn, R.; Hazelager, W. A.; Koks, C. H. W.; Underberg, W. J. M.; J. Pharm. Biomed. Anal. 1991, 9, 1173.
  • 5. Kim, S. S.; Im, H. T.; Kang, I. M.; Lee, H. S.; Lee, H. W.; Cho, S. H.; Kim, J. B.; Lee, K. T.; J. Chromatogr., B. 2007, 852, 174.
  • 6. Wattananat, T.; Akarawut, W.; Biomed. Chromatogr 2006, 20, 1.
  • 7. Peng, T-Z.; Qiong, Q.; Yang; C. F.; Fresenius J. Anal. Chem. 2001, 370, 1082.
  • 8. Shamsipur M.; Farhadi K.; Electroanalysis 2000, 12, 429.
  • 9. Pereira, F. C.; Stradiotto, N. R.; Zanoni, M. V. B.; An. Acad. Bras. Cienc. 2002, 74, 425.
  • 10. Pereira, F. C.; Stradiotto, N. R.; Zanoni, M. V. B.; J. Braz. Chem. Soc 2001, 12, 202.
  • 11. Lunte, C. E.; Osbourn, D. In Electrochemical Detection for Pharmaceutical Analysis in Encyclopedia of Pharmaceutical Technology; Swarbrick, J.; Boylan, J. C., eds.; Informa Healthcare: New York, 2007.
  • 12. Rang, H. P.; Dale, M. M.; Ritter, J. M.; Flower, R. J.; Pharmacology, 6th ed., Churchill Livingstone, Elsevier: London, 2008.
  • 13. Abou-Elenien, G. M.; El Maghrdy, A. A.; Abdel-Twab, H. R.; Electroanalysis 2001, 13, 587.
  • 14. Fotouhi, L.; Hajilari, F.; Heravi, M. M.; Electroanalysis 2002, 14, 1728.
  • 15. Oguzie, E.E.; Corros. Sci 2007, 49,1527.
  • 16. Gong, Y.; Hu, C. W.; Xia, Z. N.; J. Mol. Struct 2007, 837, 48.
  • 17. Lalitha, A.; Ramesh, S.; Rajeswari, S.; Electrochim. Acta 2005, 51, 47.
  • 18. Antonijevic, M. M.; Milic, S. M.; Petrovic, M. B.; Corros. Sci 2009, 51, 1228.
  • 19. Subramanian, R.; Lakshminarayanan, V.; Corros. Sci. 2002, 44, 535.
  • 20. Coelho, H.; Matinatti, A. F.; Benjamim de Araujo, M.; Bergold, A.M.; Bueno, F.; Rev. Bras. Cienc. Farm. 2004, 40, 235.
  • 21. Aboul-Enein, H. Y.; Goger, N. G.; Turkalp, A.; Anal. Lett. 2002, 35, 1193.
  • 22. Atay, O.; Selcuk, F.; Anal. Lett. 1996, 29, 2163.
  • 23. Hurtado, F. K.; Souza, M. J.; de Melo, J.; Rolim, C. M. B.; Lat. Am. J. Pharm. 2008, 27, 224.
  • *