Acessibilidade / Reportar erro

Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter1 1 Paper extracted from master's thesis "Evaluation of maintenance indicator of temporary double-lumen catheter for hemodialysis in a university hospital" presented to Escola de Enfermagem, Universidade de São Paulo, São Paulo, SP, Brazil.

Abstracts

OBJECTIVE:

to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo.

METHOD:

a quantitative, exploratory-descriptive and observational study. The sample was made up of 155 observations of persons with temporary double-lumen catheters, in the period March - November 2011, using the Indicator of the Maintenance of the Temporary Double Lumen Catheter for Hemodialysis.

RESULTS:

the rate of general conformity of the assistential practice corresponded to 65.8%. Of the practice's 13 components, 9 (69.2%) attained 100% conformity. The hygienization of hands by the professionals and the use of a mask by the patients during the disconnection from the hemodialysis had the worst rates (83.9%).

CONCLUSION:

although the actions evaluated are implemented in the unit, it is necessary to propose and apply educational strategies with the health team, as well as to institute periodical assessments, so as to raise the conformity rates, ensuring the quality of the hemodialysis services.

Quality of Health Care; Health Services Evaluation; Quality Indicators, Health Care; Renal Dialysis; Nursing


OBJETIVO:

avaliar a conformidade da prática assistencial de manutenção do cateter temporário duplo lúmen para hemodiálise, por meio do emprego do indicador de processo, no Hospital Universitário da Universidade de São Paulo.

MÉTODO:

estudo quantitativo, exploratório-descritivo, observacional. A casuística compôs-se de 155 observações de portadores de cateter temporário de duplo lúmen, no período de março a novembro de 2011, empregando-se o Indicador de Manutenção do Cateter Temporário Duplo Lúmen para Hemodiálise.

RESULTADOS:

o índice da conformidade geral da prática assistencial correspondeu a 65,8%. Dos 13 componentes da prática, 9 (69,2%) atingiram 100% de conformidade. A higiene das mãos pelo profissional e o uso de máscara pelo paciente, na desconexão da hemodiálise, apresentaram os piores índices (83,9%).

CONCLUSÃO:

embora as ações avaliadas estejam implementadas na unidade, há necessidade de propor e aplicar estratégias educativas à equipe de saúde, bem como instituir avaliações periódicas, no sentido de elevar os índices de conformidade garantindo a qualidade dos serviços na hemodiálise.

Qualidade da Assistência à Saúde; Avaliação de Serviços de Saúde; Indicadores de Qualidade em Assistência à Saúde; Diálise Renal; Enfermagem


OBJETIVO:

evaluar la conformidad de la práctica asistencial de mantenimiento del catéter temporario duplo lumen para hemodiálisis, por medio del empleo del indicador de proceso, en el Hospital Universitario de la Universidad de Sao Paulo.

MÉTODO:

estudio cuantitativo, exploratorio descriptivo y observacional. La casuística se compuso de 155 observaciones de portadores de catéter temporario de duplo lumen, en el período de marzo a noviembre de 2011, empleándose el Indicador de Mantenimiento del Catéter Temporario Duplo Lumen para Hemodiálisis.

RESULTADOS:

el índice de la conformidad general de la práctica asistencial correspondió a 65,8%. De los 13 componentes de la práctica, 9 (69,2%) alcanzaron 100% de conformidad. La higiene de las manos por el profesional y el uso de máscara por el paciente en la desconexión de la hemodiálisis, presentaron los peores índices (83,9%).

CONCLUSIÓN:

a pesar de que las acciones evaluadas estén implementadas en la unidad, existe la necesidad de proponer y aplicar estrategias educativas al equipo de salud, así como instituir evaluaciones periódicas, en el sentido de elevar los índices de conformidad garantizando la calidad de los servicios en la hemodiálisis.

Calidad de la Atención de la Salud; Evaluación de Servicios de Salud; Indicadores de Calidad de la Atención de Salud; Diálisis Renal; Enfermería


Introduction

In the majority of health institutions, the constant search for quality, through the use of best practice and the offer of the best service so as to meet the service users' needs and expectations, is a reality. It is no different in relation to the hemodialysis service, as the treatment is complex, with specific activities, requiring an appropriate structure and professionals who are trained to provide safe assistential practice; these needs, if not respected, can cause irreversible damage to the service user.

Quality in health care is the obtaining of greater benefits with low risks to the user. In their turn, the benefits are defined in terms of achievability, in line with the resources available and the existing social values. This is not an abstract attribute; rather, it is constructed by the assistential evaluation; according to Donabedian's evaluative model, it is proposed that this should be undertaken through the analysis of the structure, the work processes and the results( 11. Donabedian A. The quality of care. How can it be assessed? J Am Med Assoc. 1988;260(12):1743-8.

2. Donabedian A. The seven pillars of quality. Arch Pathol Lab Med. 1990; 114(11):1115-8.
- 33. Donabedian A. The role of outcomes in quality assessment and assurance. QRB Qual Rev Bull. 1992;18(11):356-60. ).

Quality includes the unceasing search for identification of shortcomings in the procedures and practices which organize the actions, leading to improvement in the processes and results, considering the conformities established by the regulatory bodies, and the satisfaction of the service users( 44. D'Innocenzo M, Adami NP, Cunha ICKO. O movimento pela qualidade nos serviços de saúde e enfermagem.Rev Bras Enferm. 2006;59(1):84-8. - 55. Feldman LB, Cunha ICKO. Identification of result evaluation criteria for nursing service in hospital accreditation programs. Rev. Latino-Am. Enfermagem. 2006;14(4):540-5. ).

The maintenance of adequate standards of the Hd in patients with kidney disease directly depends on efficient vascular access (VA), complications of which are highly represented among the morbidities in this group. Considering the importance of VA, moreover, it is worth emphasizing that the therapy's efficacy is very closely related to its appropriate implanting, handling and monitoring, which are reflected in the quality of the dialysis and, consequently, in the patient's well-being and survival( 66. Mangini C, Camargo LFA, coordenadores. Prevenção de infecção relacionada à diálise. São Paulo: APECIH - Associação Paulista de Estudos e Controle de Infecção Hospitalar; 2005. - 77. Nicole AG, Tronchin DMR. Indicadores para avaliação do acesso vascular de usuários em hemodiálise. Rev Esc Enferm USP. 2011;45(1):206-14. ).

Of the different health evaluation instruments, indicators are increasingly standing out, above all those constructed, validated and applied for analyzing a given phenomenon or situation.

In analyzing the advantages of using the processes' quality indicators, data from the literature shows that these provide concrete elements of the context, addressing the issue of the results' viability( 33. Donabedian A. The role of outcomes in quality assessment and assurance. QRB Qual Rev Bull. 1992;18(11):356-60. ). There is consensus that the services must select indicators which reflect practices or areas which need decisions to be made with as little uncertainty as possible. In this way, the information instrumentalizes the analysis of the institutional processes with rationality and criticality( 88. Bohomol E. Padrões para avaliação da qualidade da assistência de enfermagem. In: D'InnocenzoM, Feldman LB, Fazenda NRR, Helito RAB,Ruthes RM. Indicadores, auditorias, certificações. Ferramentas de qualidade para gestão em saúde. São Paulo: Martinari; 2006. p. 71-86. ).

Bearing in mind the above, and given the importance of quality linked to safe assistential practice, with a view to the continuous improvement of the Hd services (above all in the appropriate management of these services' users' VA) and, furthermore, taking into account the gap existing in the evaluation of this practice, through the use of tools for measuring quality, it was considered relevant to develop the present study, which aimed to evaluate the conformity of the assistential practice of maintenance of the temporary double-lumen catheter for hemodialysis, through the use of the process indicator, in the University Hospital of the University of São Paulo.

Method

This study has a quantitative approach and is exploratory-descriptive and observational. It was undertaken in the Hemodialysis Unit of the University Hospital of the University of São Paulo (HU-USP).

Data collection occurred in the period March - November 2011, in the morning and afternoon shifts, through structured observation. This technique involves the use of formal instruments and protocols which guide what is to be observed, how long the technique should take, and how the data should be recorded, with the aim of documenting specific behaviors, actions and events( 99. Polit DF, Beck CT, Hungler BP.Fundamentos de Pesquisa em Enfermagem: métodos, avaliação e utilização. 5ª ed. Porto Alegre: Artmed;2004. ). The researcher used two forms: the first, based on the Operational Manual of the MTDLCH Indicator( 77. Nicole AG, Tronchin DMR. Indicadores para avaliação do acesso vascular de usuários em hemodiálise. Rev Esc Enferm USP. 2011;45(1):206-14. ), used for assessing the conformity of the assistential practice, containing data referring to the number of the observation, the data, the shift, the 13 components to be evaluated and the result of the evaluation; and the second, to record the data for characterizing the service users by sex, age, and the first three diagnoses on admission to the Hd program.

The sample was made up of 155 observation opportunities, each one made up of 13 specific components, corresponding to the evaluation of 2,015 components of the practice of maintaining the temporary double-lumen catheter (TDLC) for Hd, undertaken by the health professionals. The sampling, which was non-probabilistic and of convenience, was undertaken over eight months, representing the opportunities evaluated in the Hd unit of the HU-USP.

It was considered that the conformity of the activities or processes consisted of meeting a specific standard which was able to define the desired quality in a way that did not compromise the coherence and what was called for by the service, observed during the evaluation( 22. Donabedian A. The seven pillars of quality. Arch Pathol Lab Med. 1990; 114(11):1115-8. , 1010. Organização Nacional de Acreditação - Manual Brasileiro de Acreditação. 6ª ed. Brasília; 2010. ).

The patients with Hd catheters were not approached during the study, and the data collection did not entail any alteration of the practice habitually carried out by the health professionals. The research project was submitted to the above-mentioned hospital's Nursing Department and Research Ethics Committee and was approved (Protocol nº 1.080/10 - SISNEP CAAE 0107.0.198.196-10). The health professionals working in the unit - who were, therefore, those who could be observed - were consulted regarding their availability to participate in the research and were informed about the study's objectives and the confidentiality of their identities and roles. Thus, all the professionals in the health team participated in the study, signing the Terms of Free and Informed Consent (TFIC) which were provided in two copies, one remaining with the respondent and one with the researcher, in line with Resolution nº 196/96.

The data obtained was organized in an electronic spreadsheet in the Microsoft Excel(r) program, following which it was treated through statistical analysis using the Statistical Package for the Social Sciences (SPSS(r)) software. The treatment of the data was effected through descriptive statistics.

For the calculation of the indicator rates, the researchers used the formulas, for general conformity and for each component evaluated, recommended in the Operational Manual for the indicator referred to( 77. Nicole AG, Tronchin DMR. Indicadores para avaliação do acesso vascular de usuários em hemodiálise. Rev Esc Enferm USP. 2011;45(1):206-14. ).

The result of the above formulae is presented in the form of a spidergraph, as this allows one to examine the relationship potential between all the variables analyzed, simultaneously; it is considered a visual information tool for the performance of a series of indicators and permits rapid visualization, as well as facility of comprehension regarding the performance of the object evaluated( 1111. Hinchliffe S. Implementing quality care indicators and presenting results to engage frontline staff. Nurs Times. 2009;105(25):12-4. - 1212. Sullivann J, Brust P, Wren PJ,Rich V. A staffing-effectiveness methodology for analyzing human resource and clinical/service screening indicator date. Jt Comm J Qual Saf. 2004;30(6):322-30. ).

Results

In the period of the study, 155 opportunities for observation of the assistential practice were evaluated. Each opportunity was made up of 13 specific components, totalling 2,015 observations evaluated. The researchers observed the Hd sessions of 41 service users, among whom the access was the TDLC, and these were characterized in terms of the variables sex, age, and diagnosis on admission to the Hd unit.

In relation to sex, there was a predominance of men - 31 (75.6%). In regard to age, the mean was 55 years old (sd±16.5), varying from 20 to 84 years old, the median age being 57. When the mean ages were compared between the sexes, there was no statistically-significant difference (p=0.455, Student t test). Systemic Arterial Hypertension (SAH) was diagnosed in 56.6% of the patients, followed by Acute Chronic Kidney Disease (39.5%) and Diabetes Mellitus (DM) (36.8%).

By analyzing Figure 1, it may be observed that the percentage of general conformity of the assistential practice of maintenance of the TDLC for Hd corresponds to 65.8%.

Figure 1
Distribution of conformity and non-conformity of the practice of maintenance of the TDLC, HU-USP, São Paulo, state of São Paulo (SP), Brazil, 2011

According to the results presented in the table above, one can perceive that of the 13 specific components evaluated, 9 (69.2%) achieved the maximum percentage of conformity (100%), viz: handling of the TDLC with sterile gloves; use of a mask by the health professional when disconnecting the Hd; inspection of the insertion of the TDLC during the changing of the dressing; use of alcoholic chlorhexidine 0.5% when changing the dressing; changing the dressing prior to the Hd session; covering of the dressing with sterile gauze each session or with a transparent film every 7 days, or when necessary; hygienization of the connectors with alcoholic chlorhexidine at 0.5%; filling of the tubing of the TDLC, after the session, with 10 ml of saline solution 0.9% in each tube; and filling of the tubing of the TDLC after the infusion of saline solution 0.9%, with heparin solution.

Based on the data presented in Table 1, it may be observed that regarding hand hygienization, in spite of the predominance of conformity, a considerable number of opportunities were found not to conform, showing the frailty of the adherence to the practice.

Table 1
Distribution of conformity and non-conformity of each component/variable of the practice of maintenance of the TDLC, HU-USP, São Paulo, SP, Brazil, 2011

The rates of conformity of the components of the practice of maintenance of the TDLC for Hd are grouped below in the form of a spidergraph.

The management of the quality of the data, and the visualization of the results, must also be valued and incorporated by the professionals who work with indicators.

Figure 2 evidences that in adopting the MCTDLH indicator as a tool for measuring the quality of the assistential practice, other aspects may be required, such as the construction of a culture of evaluation, guided by an educational paradigm, as much for the health professionals as for the service users, which calls for an ongoing focus on the improvement of the service provided.

Figure 2
Distribution of the conformity by component of the assistential practice evaluated, HU-USP, São Paulo, SP, Brazil, 2011

Discussion

155 observation opportunities referent to the assistential practice were evaluated, in order to compose the MTDLCH indicator. Regarding the time of day that the opportunities took place, 126 (81.3%) were during the morning shift and 29 (18.7%) during the afternoon shift, totalling 1,638 evaluations of the specific components in the morning and 377 in the afternoon. The variation in the frequency between the shifts resulted from the patients' requirements, indicating that in the HU/USP, the majority of the Hd sessions for persons with TDLC occur in the mornings.

In relation to the characteristics of persons with the catheter, this study's findings were similar to those found in the Brazilian literature( 1313. Ferreira V, Andrade D, Santos CB,Moysés Neto M. Infecção em pacientes com cateter temporário duplo-lúmen para hemodiálise. Rev Panam Infectol. 2005;7(2):16-21. ), regarding the variables of sex and age; and regarding the predominance of SAH and DM as the main diagnoses( 1414. Sesso RC, Lopes AA, Thomé FS,Lugon JR, SantosDR. Relatório do censo brasileiro de diálise de 2010. J Bras Nefrol. 2011;33(4):442-7. - 1515. Rembold SM, Santos DLS, Vieira GB,Barros MS, LugonJR. Perfil do doente renal crônico no ambulatório multidisciplinar de um hospital universitário. Acta Paul Enferm. 2009;22(n. esp):501-4. ).

The epidemiological profile of the patients undergoing Renal Replacement Therapy (RRT) in Brazil in the period 2000 - 2004 showed that most (57%) of those who started RRT by Hd were men, with a mean age of 53 years old (sd± 17) and a median age of 54 years old( 1616. Cherchiglia ML, Machado EL, Szuter DAC,Andrade EIG, AcúrcioFA, Caiaffa WT, et al. Perfil epidemiológico dos pacientes em terapia renal substitutiva no Brasil, 2000-2004. Rev Saúde Pública.2010;44(4):639-49. ). The results of other studies held with patients receiving the same therapy also showed a predominance of men( 1717. Peres LAB, Biela R, Herrmann M,Matsuo, Kyung Ann H,Camargo MTA, RohdeNRS, UscocovichVSM. Estudo epidemiológico da doença renal crônica terminal no Oeste do Paraná: uma experiência de 878 casos atendidos em 25 anos. J Bras Nefrol. 2010;32(1):51-6.

18. Bertolin DC, Pace AE, Kusomota L,Haas V. Associação entre os modos de enfrentamento e as variáveis sociodemográficas de pessoas em hemodiálise crônica. Rev Esc Enferm USP. 2011;45(5):1070-6.
- 1919. Cesarino CB, Ribeiro RCHM, Lima ICPC,Bertolin DC, RibeiroDF, RodriguesAMS. Avaliação do grau de satisfação de pacientes renais crônicos em hemodiálise. Acta Paul Enferm. 2009;22(n. esp):519-23. ).

In Brazil, between 2000 and 2004, 90,356 patients started dialysis, with the Hd modality predominating( 1616. Cherchiglia ML, Machado EL, Szuter DAC,Andrade EIG, AcúrcioFA, Caiaffa WT, et al. Perfil epidemiológico dos pacientes em terapia renal substitutiva no Brasil, 2000-2004. Rev Saúde Pública.2010;44(4):639-49. - 1717. Peres LAB, Biela R, Herrmann M,Matsuo, Kyung Ann H,Camargo MTA, RohdeNRS, UscocovichVSM. Estudo epidemiológico da doença renal crônica terminal no Oeste do Paraná: uma experiência de 878 casos atendidos em 25 anos. J Bras Nefrol. 2010;32(1):51-6. ). In 2010, it is calculated that the number of patients admitted to dialysis programs was 18,972, with the incidence rate estimated at 9.5 patients per million of the population( 1414. Sesso RC, Lopes AA, Thomé FS,Lugon JR, SantosDR. Relatório do censo brasileiro de diálise de 2010. J Bras Nefrol. 2011;33(4):442-7. ).

In this context, the maintenance of the TDLC for Hd is held as a practice of fundamental importance, undertaken predominantly by the nursing team, and depending on the professional's technical competence and dexterity, as well as on the interaction and communication of this team with the multiprofessional team and the service user so as to ensure the quality, the safety of the process, and the success of the therapy.

It may be observed in the present study's results that the percentage of general conformity in the assistential practice of maintenance of the temporary catheter for Hd was 65.8%.

In taking into account the data found in the literature, one may perceive that there has been an increase in the number of studies evaluating assistential practices; as well as great variation between them in the results of the conformity rates.

However, the best results expected are in percentages = to 80%( 1515. Rembold SM, Santos DLS, Vieira GB,Barros MS, LugonJR. Perfil do doente renal crônico no ambulatório multidisciplinar de um hospital universitário. Acta Paul Enferm. 2009;22(n. esp):501-4. ). In the comparison of this study with the best general conformity rates cited above, a difference of 14.2% was observed, denoting weaknesses in the process which may be the object of actions by the continuing education services, the object of revision of the assistential protocol, and the object of increasing participation by the service users in the health care.

The central venous catheter (CVC) is a sterile device, which requires specific care in its handling, as a result of which its handling must be carried out respecting the principles of the sterile technique; in this study, the component which corresponded to handling with aseptic technique was one of those which obtained 100% conformity.

In addition to this, it is recorded in the Brazilian and international literature that, following the same advice as given for the CVC dressing, that of the TDLC for Hd must obey the precepts of aseptic technique, using sterile gauze for each session, or transparent film, every seven days, aiming to cover the place of insertion, also applying chlorhexidine or another antiseptic solution of the professional's choice( 2020. Barros LFNM, Arênas VG, Bettencourt ARC, Diccini S,Fram DS, BelascoAGS, et al. Avaliação do tipo de curativo utilizado em cateter venoso central para hemodiálise. Acta Paul Enferm. 2009;22(n. esp):481-6. - 2121. O'Grady NP, Alexander M, Burns LA,Dellinger EP, GarlandJ, Heard SO, et al. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections, 2011. Atlanta: Centers for Disease Control and Prevention (CDC); 2011. 83 p. ).

Studies( 77. Nicole AG, Tronchin DMR. Indicadores para avaliação do acesso vascular de usuários em hemodiálise. Rev Esc Enferm USP. 2011;45(1):206-14. , 2222. Sociedad Española de Nefrologia. Guías de accesso vascular em hemodiálisis.Madrid; 2004. ) mention that changing the dressing must be undertaken prior to beginning the hemodialysis session, and recommend the professional's attention to the inspection of the catheter's exit site, these procedures being considered in the present investigation's evaluation opportunities, with a conformity rate of 100% for both practices, in addition to the use of sterile gauze or transparent film. Furthermore, in the applying of the dressing, both in the connection and disconnection of the catheter, the use of a surgical mask or face protection is recommended for the professional and patient alike, thus reducing the risks of contamination( 2121. O'Grady NP, Alexander M, Burns LA,Dellinger EP, GarlandJ, Heard SO, et al. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections, 2011. Atlanta: Centers for Disease Control and Prevention (CDC); 2011. 83 p. ).

In relation to the use of the mask in undertaking the practice evaluated, the results showed that its use by the professional in the connecting and disconnecting of the Hd was complied with in the majority of the evaluation opportunities, being 99.4% in conformity in the connection, and 100% in the disconnection.

On comparing the above-mentioned findings with those corresponding to the use of the mask by the patient in the connection and disconnection of the Hd, a lower conformity rate was evidenced in the latter, 92.3% of the opportunities being in conformity in the connection of the Hd, and 83.9% in the disconnection, which indicates the need for attention on the part of the health professionals, given that this is a conduct recommended in the literature( 77. Nicole AG, Tronchin DMR. Indicadores para avaliação do acesso vascular de usuários em hemodiálise. Rev Esc Enferm USP. 2011;45(1):206-14. ). Nevertheless, it is sometimes neglected, compromising the prevention and control of healthcare-associated infections.

In this study, it was observed that in the component of hand hygienization, in spite of the predominance of conformity - 130 (83.9%) - a considerable number of opportunities - 25 (16.1%) - were not in conformity, demonstrating the weakness in adherence to the practice. Conformity was considered to be present only when the professional undertook the practice of hand hygienization before and after the connection and disconnection of the Hd.

In the dialysis services, innumerable patients receive Hd treatment at the same time, in the same environment, which favors the dissemination of micro-organisms by direct or indirect contact via devices, equipment, surfaces or the health professionals' hands, which evidences the need for undertaking hand hygienization before and after patient contact( 2121. O'Grady NP, Alexander M, Burns LA,Dellinger EP, GarlandJ, Heard SO, et al. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections, 2011. Atlanta: Centers for Disease Control and Prevention (CDC); 2011. 83 p. ).

In a multicentric investigation carried out in nine Spanish Hd units, where the objective was to identify the factors which affect adherence to the practice of hand hygienization in Hd units, it was ascertained that in 1,902 opportunities, there was adherence of 35.6% to the practice after patient contact, and a mere 13.8% prior to patient contact( 2323. Fram DS, Taminato M, Ferreira D,Neves L, BelascoAGS, Barbosa DA. Prevenção de infecções de corrente sanguínea relacionadas a cateter em pacientes em hemodiálise. Acta Paul Enferm.2009;22(n. esp):564-8. ).

The issue described above is recurrent in the health services, and is treated as priority by the programs and initiatives which focus on safety in patient care, such as the World Alliance for Patient Safety, a WHO initiative, launched in 2005, which has dedicated efforts to elaborating guidelines and strategies for the implantation of measures, including the adherence to the practice of hand hygienization, and, more recently, in Brazil, by the Ministry of Health's Ordinance nº 529/2013, which instituted the National Program for Patient Safety( 2424. Brasil. Ministério da Saúde. Portaria GM n. 529, de 1º de abril de 2013. Institui o Programa Nacional de Segurança do Paciente (PNSP) [legislação na internet]. Brasília; 2013. [acesso 11 jul 2013]. Disponível em:http://bvsms.saude.gov.br/bvs/saudelegis/gm/2013/prt0529_01_04_2013.html
Disponível em:http://bvsms.saude.gov.br/...
).

Encouraging this practice is one of the nine solutions for patient safety launched in 2007 in the Nine Patient Safety Solutions program, considered the primary preventive measure to avoid harm to patients( 2525. Arenas MD, Sánchez-Payá J, Barril G, Garcia-Valdecasas J,Gorriz JL, SorianoA, et al. A multicentric survey of the practice of hand hygiene in haemodialysis units: factors affecting compliance. Nephrol Dial Transplant. 2005;20:1164-71. ).

In the light of the above, the specific indicator of the practice of hand hygienization has been negatively influencing the assistential processes' general rates of conformity, impairing the quality of the services and the safety of the patients.

Changing health professionals' behavior is a big challenge for the government, institutions, managers and other professionals who dedicate efforts in this direction, as it is a fundamental condition for the adherence to the recommendations and protocols directed at improving health care practices, with a view to the safety of patients and professionals in the undertaking of the procedures.

Conclusion

In using and assessing the indicator of the process of Maintenance of the Temporary Double-Lumen Catheter for Hd, it was possible to learn that this constitutes a significant tool in the monitoring of the quality of the assistential processes undertaken in the ambit of the Hd unit in the HU-USP.

In the light of the findings, the authors observe that the general rate of conformity was above 80%, a percentage indicated as the conformity expected in some studies similarly conducted to evaluate assistential practices. However, most of the 13 components of the indicator achieved 100% conformity.

In relation to the non-conformities, the hand hygienization by the professional and the use of the mask by the patient in the disconnection of the Hd predominated, both presenting the same rate in the opportunities evaluated. In this regard, the importance of the involvement of the managers and health professionals in the reviewing of these rates is ratified, exploring other elements which may influence the process, such as structural, material and behavioral issues.

In this perspective, the authors consider that the undertaking of studies with similar designs can provide results capable of promoting benchmarking among the Hd services, and produce consistent scientific evidence for supporting managerial and assistential practice, directing professionals' attention towards the importance of conformity in the carrying-out of the processes, supporting continuous improvements in the care given. Equally, they would allow consensus and the establishment of acceptable conformity rates, bearing in mind the complexity of the practices in hemodialytic therapy, and their repercussions on the safety and health of the individuals.

References

  • 1
    Donabedian A. The quality of care. How can it be assessed? J Am Med Assoc. 1988;260(12):1743-8.
  • 2
    Donabedian A. The seven pillars of quality. Arch Pathol Lab Med. 1990; 114(11):1115-8.
  • 3
    Donabedian A. The role of outcomes in quality assessment and assurance. QRB Qual Rev Bull. 1992;18(11):356-60.
  • 4
    D'Innocenzo M, Adami NP, Cunha ICKO. O movimento pela qualidade nos serviços de saúde e enfermagem.Rev Bras Enferm. 2006;59(1):84-8.
  • 5
    Feldman LB, Cunha ICKO. Identification of result evaluation criteria for nursing service in hospital accreditation programs. Rev. Latino-Am. Enfermagem. 2006;14(4):540-5.
  • 6
    Mangini C, Camargo LFA, coordenadores. Prevenção de infecção relacionada à diálise. São Paulo: APECIH - Associação Paulista de Estudos e Controle de Infecção Hospitalar; 2005.
  • 7
    Nicole AG, Tronchin DMR. Indicadores para avaliação do acesso vascular de usuários em hemodiálise. Rev Esc Enferm USP. 2011;45(1):206-14.
  • 8
    Bohomol E. Padrões para avaliação da qualidade da assistência de enfermagem. In: D'InnocenzoM, Feldman LB, Fazenda NRR, Helito RAB,Ruthes RM. Indicadores, auditorias, certificações. Ferramentas de qualidade para gestão em saúde. São Paulo: Martinari; 2006. p. 71-86.
  • 9
    Polit DF, Beck CT, Hungler BP.Fundamentos de Pesquisa em Enfermagem: métodos, avaliação e utilização. 5ª ed. Porto Alegre: Artmed;2004.
  • 10
    Organização Nacional de Acreditação - Manual Brasileiro de Acreditação. 6ª ed. Brasília; 2010.
  • 11
    Hinchliffe S. Implementing quality care indicators and presenting results to engage frontline staff. Nurs Times. 2009;105(25):12-4.
  • 12
    Sullivann J, Brust P, Wren PJ,Rich V. A staffing-effectiveness methodology for analyzing human resource and clinical/service screening indicator date. Jt Comm J Qual Saf. 2004;30(6):322-30.
  • 13
    Ferreira V, Andrade D, Santos CB,Moysés Neto M. Infecção em pacientes com cateter temporário duplo-lúmen para hemodiálise. Rev Panam Infectol. 2005;7(2):16-21.
  • 14
    Sesso RC, Lopes AA, Thomé FS,Lugon JR, SantosDR. Relatório do censo brasileiro de diálise de 2010. J Bras Nefrol. 2011;33(4):442-7.
  • 15
    Rembold SM, Santos DLS, Vieira GB,Barros MS, LugonJR. Perfil do doente renal crônico no ambulatório multidisciplinar de um hospital universitário. Acta Paul Enferm. 2009;22(n. esp):501-4.
  • 16
    Cherchiglia ML, Machado EL, Szuter DAC,Andrade EIG, AcúrcioFA, Caiaffa WT, et al. Perfil epidemiológico dos pacientes em terapia renal substitutiva no Brasil, 2000-2004. Rev Saúde Pública.2010;44(4):639-49.
  • 17
    Peres LAB, Biela R, Herrmann M,Matsuo, Kyung Ann H,Camargo MTA, RohdeNRS, UscocovichVSM. Estudo epidemiológico da doença renal crônica terminal no Oeste do Paraná: uma experiência de 878 casos atendidos em 25 anos. J Bras Nefrol. 2010;32(1):51-6.
  • 18
    Bertolin DC, Pace AE, Kusomota L,Haas V. Associação entre os modos de enfrentamento e as variáveis sociodemográficas de pessoas em hemodiálise crônica. Rev Esc Enferm USP. 2011;45(5):1070-6.
  • 19
    Cesarino CB, Ribeiro RCHM, Lima ICPC,Bertolin DC, RibeiroDF, RodriguesAMS. Avaliação do grau de satisfação de pacientes renais crônicos em hemodiálise. Acta Paul Enferm. 2009;22(n. esp):519-23.
  • 20
    Barros LFNM, Arênas VG, Bettencourt ARC, Diccini S,Fram DS, BelascoAGS, et al. Avaliação do tipo de curativo utilizado em cateter venoso central para hemodiálise. Acta Paul Enferm. 2009;22(n. esp):481-6.
  • 21
    O'Grady NP, Alexander M, Burns LA,Dellinger EP, GarlandJ, Heard SO, et al. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections, 2011. Atlanta: Centers for Disease Control and Prevention (CDC); 2011. 83 p.
  • 22
    Sociedad Española de Nefrologia. Guías de accesso vascular em hemodiálisis.Madrid; 2004.
  • 23
    Fram DS, Taminato M, Ferreira D,Neves L, BelascoAGS, Barbosa DA. Prevenção de infecções de corrente sanguínea relacionadas a cateter em pacientes em hemodiálise. Acta Paul Enferm.2009;22(n. esp):564-8.
  • 24
    Brasil. Ministério da Saúde. Portaria GM n. 529, de 1º de abril de 2013. Institui o Programa Nacional de Segurança do Paciente (PNSP) [legislação na internet]. Brasília; 2013. [acesso 11 jul 2013]. Disponível em:http://bvsms.saude.gov.br/bvs/saudelegis/gm/2013/prt0529_01_04_2013.html
    » Disponível em:http://bvsms.saude.gov.br/bvs/saudelegis/gm/2013/prt0529_01_04_2013.html
  • 25
    Arenas MD, Sánchez-Payá J, Barril G, Garcia-Valdecasas J,Gorriz JL, SorianoA, et al. A multicentric survey of the practice of hand hygiene in haemodialysis units: factors affecting compliance. Nephrol Dial Transplant. 2005;20:1164-71.
  • 1
    Paper extracted from master's thesis "Evaluation of maintenance indicator of temporary double-lumen catheter for hemodialysis in a university hospital" presented to Escola de Enfermagem, Universidade de São Paulo, São Paulo, SP, Brazil.