Acessibilidade / Reportar erro

Evaluation of the conformity of assistential practice in the maintenance of the temporary double-lumen dialysis catheter1 1 Paper extracted from master's thesis "Evaluation of maintenance indicator of temporary double-lumen catheter for hemodialysis in a university hospital" presented to Escola de Enfermagem, Universidade de São Paulo, São Paulo, SP, Brazil.

OBJECTIVE:

to evaluate the conformity of the assistential practice in the maintenance of the temporary double-lumen catheter for hemodialysis, by means of the use of the process indicator, in the University Hospital of the University of São Paulo.

METHOD:

a quantitative, exploratory-descriptive and observational study. The sample was made up of 155 observations of persons with temporary double-lumen catheters, in the period March - November 2011, using the Indicator of the Maintenance of the Temporary Double Lumen Catheter for Hemodialysis.

RESULTS:

the rate of general conformity of the assistential practice corresponded to 65.8%. Of the practice's 13 components, 9 (69.2%) attained 100% conformity. The hygienization of hands by the professionals and the use of a mask by the patients during the disconnection from the hemodialysis had the worst rates (83.9%).

CONCLUSION:

although the actions evaluated are implemented in the unit, it is necessary to propose and apply educational strategies with the health team, as well as to institute periodical assessments, so as to raise the conformity rates, ensuring the quality of the hemodialysis services.

Quality of Health Care; Health Services Evaluation; Quality Indicators, Health Care; Renal Dialysis; Nursing


Escola de Enfermagem de Ribeirão Preto / Universidade de São Paulo Av. Bandeirantes, 3900, 14040-902 Ribeirão Preto SP Brazil, Tel.: +55 (16) 3315-3451 / 3315-4407 - Ribeirão Preto - SP - Brazil
E-mail: rlae@eerp.usp.br