Lung exclusion in neonates - techniques and the role of ultrasound

We carefully read the comments and suggestions given by Mizubuti et al. and appreciate the interest shown in our article and the excellent review on lung Ultrasound (US). We would like to discuss some of the issues raised.11 Mizubuti G, Ho A. The role of point-of-care ultrasound and issues related to one-lung ventilation in neonates. Braz J Anesthesiol. 2020.

As stated, lung US provides an added value in confirming the position of the Endotracheal Tube (ETT), but as we said in our report, there are some limitations on its use being one of them, the presence of pneumothorax. Lung sliding confirms the apposition of both visceral and parietal pleurae and ventilation (as there is movement between them). Lung pulse also confirms the apposition of both pleurae, thus excluding pneumothorax, and rules out ventilation, as there is no movement between them, being a good signal of endobronchial intubation.22 Rodrigues A, Alves P, Hipólito C, et al. Will ultrasound replace the stethoscope? A case report on neonatal one-lung ventilation. Braz J Anesthesiol. 2019;69:514-6.,33 Nam JS, Park I, Seo H, et al. The use of lung ultrasonography to confirm lung isolation in an infant who underwent emergent video-assisted thoracoscopic surgery: a case report. Korean J Anesthesiol. 2015;68:411-4.

Concerning the question of coupling a 3 mm orotracheal tube with a Bronchial Blocker (BB), bronchial blockers should be placed under fibroscope view, and we should bear in mind that due to the small diameter of the ETT, during the fiberscope use, poor or no ventilation will be possible. Although this is our technique of choice in infants and small children for left lung exclusion, unfortunately, our smallest fiberscope available is 2.8 mm. This precluded the use of this technique in our case, as a 3.5 mm ETT plus BB outside the ETT would be too large for a neonate trachea. We suggest the use of the CT scan to determine the trachea and main bronchus diameter and prevent the use of a too big ETT or ETT + BB combination, though not completely ruling out the risk of injury.44 Shiqing L, Wenxu Q, Jin Z, et al. The combination of diameters of cricoid ring and left main bronchus for selecting the ‘best fit’ double-lumen tube. J Cardiothorac Vasc Anesth. 2018;32:869-76.

In our case report, lung exclusion was performed using a single-lumen endotracheal tube and we agree that this is not the ideal lung exclusion technique and has several disadvantages as we pointed out in our report. One of which, as highlighted by Mizubuti et al., would be the possible exclusion of the right upper lobe orifice if it was positioned above or very close to the carina. A problem that we might not be able to overcome also using an extraluminal BB on the right main bronchus.55 Ho A, Karmakar M, Critchley L, et al. Placing the tip of the endotracheal tube at the carina and passing the endobronchial blocker through the Murphy eye may reduce the risk of blocker retrograde dislodgement during one-lung anaesthesia in small children. Br J Anaesth. 2008;101:690-3. Aiming to confirm the right upper lobe ventilation, we needed a more accurate method than auscultation and the US arises as a more reliable and precise technique.22 Rodrigues A, Alves P, Hipólito C, et al. Will ultrasound replace the stethoscope? A case report on neonatal one-lung ventilation. Braz J Anesthesiol. 2019;69:514-6.

The risk of bronchial injury and even tracheomalacia in the case of bronchial intubation should always be considered, especially in neonates. The possible need to reposition of the ETT may be more cumbersome and cause tracheobronchial injuries, however, we cannot ignore that this problem happens even with the use of BB. Bronchial blocker insufflation may cause excessive pressure on the bronchial mucosa, which may be a concern, especially in longer surgeries.55 Ho A, Karmakar M, Critchley L, et al. Placing the tip of the endotracheal tube at the carina and passing the endobronchial blocker through the Murphy eye may reduce the risk of blocker retrograde dislodgement during one-lung anaesthesia in small children. Br J Anaesth. 2008;101:690-3.

Nevertheless, we agree that the technique proposed by Mizubuti et al. would also be a good option for OLV in neonates. Still, there is little evidence on the best technique for OLV in neonates and infants, as most of our knowledge comes from case reports and case series.

References

  • 1
    Mizubuti G, Ho A. The role of point-of-care ultrasound and issues related to one-lung ventilation in neonates. Braz J Anesthesiol. 2020.
  • 2
    Rodrigues A, Alves P, Hipólito C, et al. Will ultrasound replace the stethoscope? A case report on neonatal one-lung ventilation. Braz J Anesthesiol. 2019;69:514-6.
  • 3
    Nam JS, Park I, Seo H, et al. The use of lung ultrasonography to confirm lung isolation in an infant who underwent emergent video-assisted thoracoscopic surgery: a case report. Korean J Anesthesiol. 2015;68:411-4.
  • 4
    Shiqing L, Wenxu Q, Jin Z, et al. The combination of diameters of cricoid ring and left main bronchus for selecting the ‘best fit’ double-lumen tube. J Cardiothorac Vasc Anesth. 2018;32:869-76.
  • 5
    Ho A, Karmakar M, Critchley L, et al. Placing the tip of the endotracheal tube at the carina and passing the endobronchial blocker through the Murphy eye may reduce the risk of blocker retrograde dislodgement during one-lung anaesthesia in small children. Br J Anaesth. 2008;101:690-3.

Publication Dates

  • Publication in this collection
    14 Sept 2020
  • Date of issue
    May-Jun 2020
Sociedade Brasileira de Anestesiologia R. Professor Alfredo Gomes, 36, 22251-080 Botafogo RJ Brasil, Tel: +55 21 2537-8100, Fax: +55 21 2537-8188 - Campinas - SP - Brazil
E-mail: bjan@sbahq.org