Acessibilidade / Reportar erro

Antimicrobial action of ozone gas on surfaces and in the air

Abstract

Objective:

Assess the antimicrobial action of ozone gas (O3) on surfaces and artificially cooled ambient air.

Methods:

Cross-sectional experimental/laboratory study carried out in ten rooms of a medical microbiology research lab, with class 2 biosafety risk. The demarcated surfaces on the floor, wall and counter were assessed in relation to the presence or absence of microorganisms, based on collections done with swabs dampened in sterile distilled water, before and after exposure to ozone gas produced by two different generators. After this procedure, each swab was inoculated on the surface of a Brain Heart Infusion Agar DIFCO® (BHI) culture, followed by incubation at 35ºC for 24 hours. For the microbiological analysis of the air, a petri dish with BHI was openly exposed for one hour, before and after treatment with O3 gas, and were incubated according to the same criteria.

Results:

The antimicrobial activity of the O3 gas produced by both generators was checked in all the areas investigated, with records indicating a decrease in the number of colony-forming units. The antimicrobial inhibition potential of the generators was close to the analysis criteria adopted, particularly for the floor and counter areas. Based on all the rooms and microbial inhibition percentages, in relation to the two generators, the results were: floor (100%), counter (90%), wall (50%) and air (70%).

Conclusion:

The O3 generators had antimicrobial potential as a procedure for controlling microorganisms present on surfaces and in artificially cooled ambient air, constituting a feasible sanitizer.

Keywords
Anti-infective agents; Ozone; Ozonation; Disinfection; Products with antimicrobial action; Air pollution; indoor

Resumo

Objetivo:

Avaliar a ação antimicrobiano do gás ozônio (O3) em superfícies e ar ambiente climatizado artificialmente.

Métodos:

Estudo experimental/laboratorial e transversal realizado em dez salas de um laboratório de pesquisa em microbiologia médica, com risco de segurança biológica classe 2. As superfícies demarcadas do chão, parede e bancada foram avaliadas, quanto à presença ou ausência de micro-organismos, a partir de coletas feitas com swab umedecido em água destilada estéril, antes e após a exposição do gás O3 gerado por dois equipamentos distintos. Após este procedimento, o swab foi inoculado na superfície do meio de cultura Brain Heart Infusion Agar DIFCO® (BHI), seguindo-se a incubação a 35ºC por 24 horas. Para a análise microbiológica do ar, uma placa com BHI foi exposta aberta por uma hora, antes e após o tratamento do gás O3, sendo incubadas segundo os mesmos critérios.

Resultados:

A atividade antimicrobiana do gás O3 gerado por ambos os equipamentos foi constatada para todas as áreas investigadas, com registros de redução do número de Unidades Formadoras de Colônias. O potencial de inibição antimicrobiana dos aparelhos se manteve próximo para os critérios de análise adotados, com destaque para as áreas de chão e bancada. Considerando-se todas as salas e percentuais de inibição microbiana, frente aos dois equipamentos, os resultados foram: chão (100%), bancada (90%), parede (50%) e ar, 70%.

Conclusão:

Os equipamentos geradores de gás O3 apresentaram potencial antimicrobiano para medida de controle de microrganismos presentes em superfícies e ar ambiente climatizado artificialmente, sendo um sanitizante factível para utilização.

Descritores
Anti-infecciosos; Ozônio; Ozonização; Desinfecção; Produtos com ação antimicrobiana; Poluição do ar em ambientes fechados

Resumen

Objetivo:

Evaluar la acción antimicrobiana del gas ozono (O3) en superficies y en el aire interior climatizado artificialmente.

Métodos:

Estudio experimental/de laboratorio y transversal realizado en diez salas de un laboratorio de investigación en microbiología médica, con riesgo de seguridad biológica clase 2. Se evaluaron las superficies delimitadas en el piso, pared y mesa en cuanto a la presencia o ausencia de microorganismos, a partir de muestras recolectadas con hisopo humedecido en agua destilada estéril, antes y después de la exposición del gas O3 generado por dos máquinas distintas. Luego de este procedimiento, el hisopo fue inoculado en la superficie del medio de cultivo Brain Heart Infusion Agar DIFCO® (BHI), y después incubado a 35 °C por 24 horas. Para el análisis microbiológico del aire, se expuso una placa con BHI abierta durante una hora, antes y después del tratamiento del gas O3, y luego se incubó con los mismos criterios.

Resultados:

Se constató la actividad antimicrobiana del gas O3 generado por ambas máquinas en todas las áreas investigadas, y se registró una reducción del número de unidades formadoras de colonias. El potencial de inhibición antimicrobiana de los dispositivos se mantuvo próximo a los criterios de análisis adoptados, con énfasis en el área del piso y mesa. Considerando todas las salas y porcentajes de inhibición microbiana, con las dos máquinas, los resultados fueron: piso (100 %), mesa (90 %), pared (50 %) y aire (70 %).

Conclusión:

Las máquinas generadoras de gas O3 presentaron potencial antimicrobiano como medida de control de microorganismos presentes en superficies y aire interior climatizado artificialmente, lo que lo convierte en un desinfectante factible para ser usado.

Descriptores
Antiinfecciosos; Ozono; Ozonización; Desinfección; Productos con acción antimicrobiana; Contaminación del aire interior

Introduction

The control of healthcare-associated infections (HAI) is a sensitive public health issue, since it results in morbidity, mortality and high costs, particularly in developing countries.(11. Giroti AL, Ferreira AM, Rigotti MA, Sousa ÁF, Frota OP, Andrade D. Hospital infection control programs: assessment of process and structure indicators. Rev Esc Enferm USP. 2018 ;52:e03364.33. Padoveze MC, Juskevicius LF, Santos TR, Nichiata LI, Ciosak SI, Bertolozzi MR. The concept of vulnerability applied to Healthcare-associated Infections. Rev Bras Enferm. 2019;72(1):299–303.)

Environments participate in the transmission of microorganisms, with contamination of inanimate surfaces acting as potential reservoirs. Equipment and surfaces in hospital areas play a role in disseminating HAI, often as secondary reservoirs, and can promote cross-contamination.(44. Furlan MC, Ferreira AM, da Silva Barcelos L, Rigotti MA, de Sousa AF, Dos Santos Junior AG, et al. Evaluation of disinfection of surfaces at an outpatient unit before and after an intervention program. BMC Infect Dis. 2019;19(1):355.) Likewise important in this context, the use of air conditioners as an artificial ambient cooling practice recycles air with microbial and aerosol particles, which impair air quality and are a risk factor for infectious disease.(55. Silva D, Nazaré D, Muniz J, Câmara C. [Hospital-acquired infections associated with poor air quality in air-conditioned environments]. J Epidemiol Infect Control. 2013;3(4):153–7. Portuguese.)

Cleaning and disinfection practices for environments, surfaces and equipment are part of infection control programs, in an effort to prepare environments and minimize disease risk.(44. Furlan MC, Ferreira AM, da Silva Barcelos L, Rigotti MA, de Sousa AF, Dos Santos Junior AG, et al. Evaluation of disinfection of surfaces at an outpatient unit before and after an intervention program. BMC Infect Dis. 2019;19(1):355.,66. Frota OP, Ferreira AM, Guerra OG, Rigotti MA, Andrade D, Borges NM, et al. Efficiency of cleaning and disinfection of surfaces: correlation between assessment methods. Rev Bras Enferm. 2017;70(6):1176–83.,77. Han JH, Sullivan N, Leas BF, Pegues DA, Kaczmarek JL, Umscheid CA. Cleaning hospital room surfaces to prevent health care–associated infections. Ann Intern Med. 2015;163(8):598–607.) In this regard, the use of disinfectants is a standard practice for microbial control, including vaporization with formaldehyde, peracetic acid or chlorhexidine, sodium hypochlorite and formulations isolated or combined with hydrogen peroxide.(88. Sato Y, Ishihara M, Nakamura S, Fukuda K, Kuwabara M, Takayama T, et al. Comparison of various disinfectants on bactericidal activity under organic matter contaminated environments. Biocontrol Sci. 2019;24(2):103–8.) There are disadvantages with these methods, such as high costs and preparation of labor, as well as the possibility that employees working close to the products will inhale toxic vapors.(99. Chughtai AA, Stelzer-Braid S, Rawlinson W, Pontivivo G, Wang Q, Pan Y, et al. Contamination by respiratory viruses on outer surface of medical masks used by hospital healthcare workers. BMC Infect Dis. 2019;19(1):491.,1010. West AM, Teska PJ, Lineback CB, Oliver HF. Strain, disinfectant, concentration, and contact time quantitatively impact disinfectant efficacy. Antimicrob Resist Infect Control. 2018;7(1):49.)

In this context, ozone is presented in the triatomic form of oxygen (O3) and has been used as a chemical element to control microorganisms in various segments of the health sector, particularly in hospital waste treatment,(1111. Hansen KM, Spiliotopoulou A, Chhetri RK, Escolà Casas M, Bester K, Andersen HR. Ozonation for source treatment of pharmaceuticals in hospital wastewater–ozone lifetime and required ozone dose. Chem Eng J. 2016;290:507–14.) pretreatment of dental cavities,(1212. Sancakli HS, Siso SH, Yildiz SO, Gökçe YB. Antibacterial effect of surface pretreatment techniques against Streptococcus Mutans. Niger J Clin Pract. 201821(2):170–5.) disinfection of hemodialysis machines(1313. Canada ML, Abelan US, Zangaro RA, Kozusny-Andreani DI, Yamazaki RF. Effectiveness of ozonated water in the reprocessing of blood dialyzers. Rev Bras Eng Bioméd. 2014;30(3):215–9.) and disinfection of operating rooms,(1414. Garcia CA, Naves JH, Neves SM, Stanziola L, Vieira IS. Ozone gas in the decontamination of surgical environments]. Vet Not. 2008;14(2):37–40. Portuguese.) among others.

In the food sector, the sanitization process has been structured by ozone generators, resulting in adequate environments for cheese ripening processes.(1515. Pinto AT, Schmidt V, Raimundo SA, Raihmer F. Uso de ozônio no controle de fungos em sala de maturação de queijos. Acta Sci Vet. 2007;35(3):333–7.1717. Cavalcante DA, Leite Júnior BR, Tribst AA, Cristianini M. Uso de ozônio gasoso na sanitização de câmaras frigoríficas. Rev Inst Laticínios Cândido Tostes. 2014;69(2):121–8.)

In terms of antimicrobial action, O3 acts in the oxidation of glycopeptides, glycoproteins and amino acids of the cell wall, modifying permeability and causing cell lysis. When it penetrates the interior of the cell, O3 recombines with cytoplasmic elements leading to the oxidation of amino acids and nucleic acids and, consequently, to cleavage and cell death. O3 also promotes the collapse of cellular enzymatic activity, attacking the sulfhydryl enzyme groups, as well as modifying the purine and pyrimidine bases of nucleic acids.(1818. Tormin SC, Navarini A, Almeida JO, Travassos LH, Negri MV, Silva RA. [Analysis of bactericidal effect of ozone on multi-resistant bacteria] [Portuguese]. Arq Med Hosp Fac Cienc Med Santa Casa São Paulo. 2016;61:138–41.2020. Martins CC, Kozusny-Andreani DI, Mendes EC. [Ozone in the control of microorganisms in health care waste]. ‎Rev Baiana Enferm. 2015;29(4):318-27. Portuguese .)

Although it has been used in hospital environments for some time, little is known about the potential of this agent, particularly in the Brazilian care context, as seen by the scarcity of studies on the topic. Therefore, this study sought to assess the antimicrobial action of ozone gas on surfaces and artificially cooled ambient air.

Methods

Type of study

This was a cross-sectional experimental/laboratory study carried out in ten internal rooms of a clinical microbiological research laboratory, which performs bacteriological and mycological tests as a part of its research projects. This environment adheres to biosafety criteria - Biosafety Level 2 (BN2), and has stable physical-chemical conditions (humidity, temperature and standard cleaning and disinfection). However, it is characterized as a critical area, with the possibility of microbial contamination. The rooms had common data in terms of physical space, lighting, temperature, humidity and circulation of people and were, therefore, subject to the same microbial risk conditions. The counters contained: ovens, lighting, water bathes, computers and wood cupboards.

Study protocol

Ten climate-controlled rooms, with an area of 9 m2, underwent a microbiological analysis before and after exposure to O3 gas, generated by two O3 generators - GEO 20000/AR-TD (Mod. I) and GEO 20000/AR (Mod. II), manufactured by the company OZON® (Chart 1). The O3 was produced through electrochemical discharge; the equipment was composed of two electrodes (high and low voltage) which are subjected to different action potentials, and the passage of air (O2) between the two electrodes produces an electrostatic change, with generation of O3. It should be noted that the environment in which O3 was being generated was free of people. The experiments, conducted with the two generators I and II, occurred in six-month intervals.

Chart 1
Models GEO 20000/AR-TD (Mod. I) and GEO 20000/ AR (Mod. II)

For the microbiological investigation of the wall, floor and counter surfaces, the collection was done using a swab pre-moistened in sterile distilled water, which was placed in contact with a specific area of 30X30 cm2 quadrant. The swab was then immediately inoculated on the surface of a culture medium containing BHI and incubated at 35ºC for 24 hours. In the next stage of the experiment, the O3 generators located on the floor in the center of the rooms was turned on for an hour. The investigation site was kept shut and sealed throughout the sanitization procedure, without any interference. At the end of this period, a new collection was performed, using another swab, placed this time in contact with the surface diametrically opposite the quadrant, following the same analysis procedures as in the first stage. Figure 1 illustrates the investigated sites, as well as the arrangement of the ozone generator.

Figure 1
Illustration of the arrangement of the ozone generator and collection points

The ambient air samples were collected through a simple sedimentation technique, before and after exposure to O3 gas, and constituted an investigation parameter, with exposure of Petri dishes, containing BHI, kept open for one hour and incubated at 35°C for 24 hours (Figure 2). The temperature and humidity of the rooms were monitored.

Figure 2
Illustration of the arrangement of the Petri dish for the air analysis.

Antimicrobial action was determined by the number of colony-forming units (CFU) on the surface of the Petri dish, from inocula from the floor, counter and wall surfaces and ambient air, before and after treatment with O3.

The classic and consensual recommendation of safe methods for disinfecting surfaces entails prior cleaning of the site, followed by disinfection with a microbicide agent.(2121. Agência Nacional de Vigilância Sanitária (ANVISA). Segurança do paciente em serviços de saúde: limpeza e desinfecção de superfícies. Brasília (DF): ANVISA [Internet]. 2012 [citado 2020 Jan 21]. Disponível em: https://www20.anvisa.gov.br/segurancadopaciente/index.php/publicacoes/item/seguranca-do-paciente-em-servicos-de-saude-limpeza-e-desinfeccao-de-superficies
https://www20.anvisa.gov.br/segurancadop...
) In the present study, the surfaces were analyzed without any prior cleaning process, since the objective was to determine microbial reduction.

Data analysis

The collected data was consolidated in SPSS (20.0) software and underwent a statistical analysis, using the paired student’s t-test, to compare two samples (before and after) and determine whether there was a significant difference in a variable between the two groups of interest. The Wilcoxon test, a nonparametric method for comparing two samples, was used to verify the overall efficiency of the ozone generators.

Results

The antimicrobial action of the ozone gas was effective for all the areas studied, there was a reduction in the CFU count, in relation to the two generators (Tables 1 and 2).

Table 1
Numerical presentation of CFU and percentages obtained before (B) and after (A) exposure to ozone (Generator I) in ten rooms
Table 2
Numerical presentation of CFU and percentages obtained before (B) and after (A) exposure to ozone (Generator II) in ten rooms

In terms of the ozone activity from generator I, on the floor of all the rooms, there was a reduction in microbial load (CFU) and a negative count in room 1. The findings were the same for the counters, except for room 4, which maintained the same colony count before and after exposure to ozone. As for the walls, there was a 50% reduction in microbial contamination. In the ambient air analysis, contamination was reduced in seven rooms; in the other rooms no microorganisms were detected either before (B) or after (A) exposure to O3.

The results obtained from the antimicrobial activity of the ozone gas with generator II are presented in Table 2. Once again, antimicrobial activity was evident, as shown by the reduction in CFU for all the variables examined, such as the air and surfaces, before and after exposure to O3 gas. The amount of CFU only remained constant in two rooms (4 and 9) for the two investigation periods.

Regardless of the generators, microbial control was higher for the floor and counter areas. In addition, considering all the areas investigated, Mod. I and Mod. II had statistically significant differences (p<0.05). When assessed separately, in relation to each one of the surfaces and ambient air, the results were not significant except for the wall (p=0.0639) and counter (p=0.1267), respectively.

It should be noted that generators I and II had distinct ozone gas flows and concentrations, i.e., 200 and 100 m3/h - 2.0 and 2.1 ppm of ozone gas, respectively. The temperature and humidity recordings of the rooms were 21ºC and 58% for the two investigation periods.

Discussion

This study has limitations associated with the study design (experimental-laboratory and cross-sectional). The environmental condition of the laboratory rooms was considered as a parameter of analysis and inference for the hospital environment. However, this does not detract from the importance of the research as a prototype for the evaluation of microbiological action, in two periods of investigation - before and after exposure to ozone. In this sense, the researchers sought to mimic the reality of environments, in terms of the occurrence of microorganisms present on surfaces and in the air, introduce the sanitization process and then develop environmental hygiene protocols.

The practical applicability of O3 gas in hospital environments could improve microbiological conditions, and thereby prevent or help reduce HAI rates. Furthermore, the portable nature of the equipment makes the sanitization process mobile and feasible for monitoring specific hospital areas.

It is known that O3 is part of the disinfection and sanitization routine of other environments,(2222. Coelho CC, Freitas-Silva O, Campos RS, Bezerra VS, Cabral LM. [Ozonation as post-harvest technology in conservation of fruits and vegetables: A review]. Rev Bras Eng Agríc Ambiental. 2015;19(4):369–75. Portuguese) with controls for bacteria and fungus.(1515. Pinto AT, Schmidt V, Raimundo SA, Raihmer F. Uso de ozônio no controle de fungos em sala de maturação de queijos. Acta Sci Vet. 2007;35(3):333–7.,1717. Cavalcante DA, Leite Júnior BR, Tribst AA, Cristianini M. Uso de ozônio gasoso na sanitização de câmaras frigoríficas. Rev Inst Laticínios Cândido Tostes. 2014;69(2):121–8.) However, this study expands what is already known about the gas, in that halting microbial growth or reducing the CFU count on Petri dishes after the application of O3 gas to any of the surfaces analyzed, compared to the control group, proves the effectiveness of the chemical compound in microbial control processes. Similar findings were reported in a study on the decontamination of operating rooms in a veterinary hospital.(1414. Garcia CA, Naves JH, Neves SM, Stanziola L, Vieira IS. Ozone gas in the decontamination of surgical environments]. Vet Not. 2008;14(2):37–40. Portuguese.) The two studies clearly demonstrated the potential of O3 gas in environmental disinfection processes, since the decrease in the count of mesophilic aerobes, molds and yeasts occurred frequently.

In terms of the microbial elimination process by O3 gas, it is known that cell destruction occurs through oxidation of structural elements, without specifying targets present in bacterial or fungal cells.(1818. Tormin SC, Navarini A, Almeida JO, Travassos LH, Negri MV, Silva RA. [Analysis of bactericidal effect of ozone on multi-resistant bacteria] [Portuguese]. Arq Med Hosp Fac Cienc Med Santa Casa São Paulo. 2016;61:138–41.) In this sense, multi-drug resistant organisms can be eliminated, with significant advantages, when compared with mechanical disinfection methods that use liquid disinfectants for environmental surfaces in healthcare facilities, including hospital environments, where it is common to use other chemical compounds in liquid form.

Biological samples which indicate that environments or surfaces are probable reservoirs for HAI transmission are essential in epidemiological studies.(2323. Otter JA, Yezli S, French GL. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol. 2011;32(7):687–99.,2424. Rutala WA, Weber DJ. Are room decontamination units needed to prevent transmission of environmental pathogens? Infect Control Hosp Epidemiol. 2011;32(8):743–7.) In hospitals, terminal cleaning is done in areas and surfaces close to or in contact with patients, after their departure, whether through their death, transfer or end of isolation,(2424. Rutala WA, Weber DJ. Are room decontamination units needed to prevent transmission of environmental pathogens? Infect Control Hosp Epidemiol. 2011;32(8):743–7.2727. Mitchell BG, Hall L, White N, Barnett AG, Halton K, Paterson DL, et al. An environmental cleaning bundle and health-care-associated infections in hospitals (REACH): a multicentre, randomised trial. Lancet Infect Dis. 2019;19(4):410–8.) and, despite efforts, disinfection and cleaning results are not always satisfactory.(2828. Rutala WA, Weber DJ. Monitoring and improving the effectiveness of surface cleaning and disinfection. Am J Infect Control. 2016;44(5 Suppl):e69–76.,2929. Doll M, Stevens M, Bearman G. Environmental cleaning and disinfection of patient areas. Int J Infect Dis. 2018;67:52–7.) The use of O3 gas in the study provided scientific proof regarding its microbial control potential, making it a compound that can be used as a sanitization procedure for healthcare environments.

In this study, differences were noted between the two O3 generators in terms of antimicrobial potential under the same conditions in the sanitization of environments, particularly in relation to flow and output power of the devices. The results indicated significant differences for certain parameters; however, in general terms, the sanitization potential of the two models was nearly the same. Innovative protocols could be created to improve the antimicrobial pattern detected in the study.

CFU values varied from one room to another. This shows that an environment does not always have the same microbiological conditions, which is to be expected considering hospital environments. Due to the demarcation of the areas investigated, before and after treatment with O3 gas, only a limited surface area was sampled, which does not ensure that the results would be the same throughout the extension of the surfaces. However, sanitization practices using ozone, generated by portable equipment, certainly enables implementation of new microbial control measures in hospital environments.

The floor and counter surfaces had higher CFU counts and, at the same time, corresponded to the areas of greater microbial inhibition by ozone. Microbial particles are dense in relation to air, which normally contributes to the permanence of potential pathogens on the floors of nosocomial environments.(3030. Salimifard P, Rim D, Gomes C, Kremer P, Freihaut JD. Resuspension of biological particles from indoor surfaces: effects of humidity and air swirl. Sci Total Environ. 2017;583:241–7.) In this sense, portable equipment can be moved close to areas of high environmental contamination and reduce the microbial load.

According to the literature, the antimicrobial effect of O3 depends on certain factors, such as exposure time, concentration, temperature and humidity.(3131. Kim JG, Yousef AE, Dave S. Application of ozone for enhancing the microbiological safety and quality of foods: a review. J Food Prot. 1999;62(9):1071–87.) However, in the current study, these criteria were assessed and maintained under equal experimental conditions, thereby minimizing possible biases. In this sense, other studies are needed that consider other parameters of temperature, relative humidity, concentration and exposure time.

When inhaled in high concentration, O3 can be toxic and has respiratory health risks.(3232. Nuvolone D, Petri D, Voller F. The effects of ozone on human health. Environ Sci Pollut Res Int. 2018;25(9):8074–88.) The two pieces of equipment tested generate a small amount of ozone (2.0 - 2.1 ppm) and, during their use, no one should remain in the environment.

Little importance was given to the training of the group from the Surface Cleaning and Disinfection Service in Health Service, which plays an essential role in reducing HAI. Therefore, cleaning and disinfection practices for environments, equipment and surfaces must be part of Hospital Infection Control Committees, along with nursing and cleaning services, carrying out activities related to environmental hygiene protocols, supervision and training of teams.(3333. Furlan MC, Ferreira AM, Rigotti MA, Guerra OG, Frota OP, Sousa AF, et al. Correlation among monitoring methods of surface cleaning and disinfection in outpatient facilities. Acta Paul Enferm. 2019;32(3):282–9.,3434. Paina T, Rodrigues JN, Felippe JC, Nogueira PC, Paiva SM. Conhecimento de auxiliares de higienização sobre limpeza e desinfecção relacionados à infecção hospitalar. Rev Enferm UFSM. 2015;5(1):121–30.) Another important point in the utilization of technologies that do not use mechanical action for disinfecting environments and surfaces is that they do not ensure that adjacent areas will be disinfected. Nor do they replace mechanical cleaning and disinfection activities.(3535. Weber DJ, Kanamori H, Rutala WA. ‘No touch’ technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems. Curr Opin Infect Dis. 2016;29(4):424–31.)

Finally, the search for new products or methods and hospital practices for disinfecting surfaces and reducing air microbiota through artificial cooling has been increasing over time, and ozone gas is a promising compound. There are still not many studies in the literature that address this object of research and those that do have highly varied experimental conditions, which suggests the need to create well-designed protocols for microbial control.

Conclusion

The findings of the present study demonstrate the antimicrobial potential of O3 gas, produced by two generators and according to the criteria set forth, ensure antimicrobial action. Applying ozone to environments is a practical procedure for sanitizing surfaces and artificially cooled air. It appears that this technology is feasible for use in various segments which seek to reduce microbial density. This resource could be used in protocols for sanitizing hospital environments and surfaces, due to its quick and easy execution and ability to control microbial development, an essential condition for maintaining microbiologically safe environmental quality.

Acknowledgements

This study was carried out with support from the Federal University of Mato Grosso do Sul (UFMS/MEC–Brazil) and the Coordination for the Improvement of Higher Education Personnel (CAPES) – Financing Code 001.

Referências

  • 1
    Giroti AL, Ferreira AM, Rigotti MA, Sousa ÁF, Frota OP, Andrade D. Hospital infection control programs: assessment of process and structure indicators. Rev Esc Enferm USP. 2018 ;52:e03364.
  • 2
    Santos-Junior AG, Ferreira AM, Frota OP, Rigotti MA, Barcelos LD, Lopes de Sousa AF, et al. Effectiveness of surface cleaning and disinfection in a Brazilian healthcare facility. Open Nurs J. 2018;12:36–44.
  • 3
    Padoveze MC, Juskevicius LF, Santos TR, Nichiata LI, Ciosak SI, Bertolozzi MR. The concept of vulnerability applied to Healthcare-associated Infections. Rev Bras Enferm. 2019;72(1):299–303.
  • 4
    Furlan MC, Ferreira AM, da Silva Barcelos L, Rigotti MA, de Sousa AF, Dos Santos Junior AG, et al. Evaluation of disinfection of surfaces at an outpatient unit before and after an intervention program. BMC Infect Dis. 2019;19(1):355.
  • 5
    Silva D, Nazaré D, Muniz J, Câmara C. [Hospital-acquired infections associated with poor air quality in air-conditioned environments]. J Epidemiol Infect Control. 2013;3(4):153–7. Portuguese.
  • 6
    Frota OP, Ferreira AM, Guerra OG, Rigotti MA, Andrade D, Borges NM, et al. Efficiency of cleaning and disinfection of surfaces: correlation between assessment methods. Rev Bras Enferm. 2017;70(6):1176–83.
  • 7
    Han JH, Sullivan N, Leas BF, Pegues DA, Kaczmarek JL, Umscheid CA. Cleaning hospital room surfaces to prevent health care–associated infections. Ann Intern Med. 2015;163(8):598–607.
  • 8
    Sato Y, Ishihara M, Nakamura S, Fukuda K, Kuwabara M, Takayama T, et al. Comparison of various disinfectants on bactericidal activity under organic matter contaminated environments. Biocontrol Sci. 2019;24(2):103–8.
  • 9
    Chughtai AA, Stelzer-Braid S, Rawlinson W, Pontivivo G, Wang Q, Pan Y, et al. Contamination by respiratory viruses on outer surface of medical masks used by hospital healthcare workers. BMC Infect Dis. 2019;19(1):491.
  • 10
    West AM, Teska PJ, Lineback CB, Oliver HF. Strain, disinfectant, concentration, and contact time quantitatively impact disinfectant efficacy. Antimicrob Resist Infect Control. 2018;7(1):49.
  • 11
    Hansen KM, Spiliotopoulou A, Chhetri RK, Escolà Casas M, Bester K, Andersen HR. Ozonation for source treatment of pharmaceuticals in hospital wastewater–ozone lifetime and required ozone dose. Chem Eng J. 2016;290:507–14.
  • 12
    Sancakli HS, Siso SH, Yildiz SO, Gökçe YB. Antibacterial effect of surface pretreatment techniques against Streptococcus Mutans Niger J Clin Pract. 201821(2):170–5.
  • 13
    Canada ML, Abelan US, Zangaro RA, Kozusny-Andreani DI, Yamazaki RF. Effectiveness of ozonated water in the reprocessing of blood dialyzers. Rev Bras Eng Bioméd. 2014;30(3):215–9.
  • 14
    Garcia CA, Naves JH, Neves SM, Stanziola L, Vieira IS. Ozone gas in the decontamination of surgical environments]. Vet Not. 2008;14(2):37–40. Portuguese.
  • 15
    Pinto AT, Schmidt V, Raimundo SA, Raihmer F. Uso de ozônio no controle de fungos em sala de maturação de queijos. Acta Sci Vet. 2007;35(3):333–7.
  • 16
    Lanita CS, Silva SB. [Use of ozone in industrial cold rooms to control yeasts and moulds during parmesan cheese ripening]. Braz J Food Technol. 2008;11(3):182–9. Portuguese.
  • 17
    Cavalcante DA, Leite Júnior BR, Tribst AA, Cristianini M. Uso de ozônio gasoso na sanitização de câmaras frigoríficas. Rev Inst Laticínios Cândido Tostes. 2014;69(2):121–8.
  • 18
    Tormin SC, Navarini A, Almeida JO, Travassos LH, Negri MV, Silva RA. [Analysis of bactericidal effect of ozone on multi-resistant bacteria] [Portuguese]. Arq Med Hosp Fac Cienc Med Santa Casa São Paulo. 2016;61:138–41.
  • 19
    Hunt NK, Mariñas BJ. Inactivation of Escherichia coli with ozone: chemical and inactivation kinetics. Water Res. 1999;33(11):2633–41.
  • 20
    Martins CC, Kozusny-Andreani DI, Mendes EC. [Ozone in the control of microorganisms in health care waste]. ‎Rev Baiana Enferm. 2015;29(4):318-27. Portuguese .
  • 21
    Agência Nacional de Vigilância Sanitária (ANVISA). Segurança do paciente em serviços de saúde: limpeza e desinfecção de superfícies. Brasília (DF): ANVISA [Internet]. 2012 [citado 2020 Jan 21]. Disponível em: https://www20.anvisa.gov.br/segurancadopaciente/index.php/publicacoes/item/seguranca-do-paciente-em-servicos-de-saude-limpeza-e-desinfeccao-de-superficies
    » https://www20.anvisa.gov.br/segurancadopaciente/index.php/publicacoes/item/seguranca-do-paciente-em-servicos-de-saude-limpeza-e-desinfeccao-de-superficies
  • 22
    Coelho CC, Freitas-Silva O, Campos RS, Bezerra VS, Cabral LM. [Ozonation as post-harvest technology in conservation of fruits and vegetables: A review]. Rev Bras Eng Agríc Ambiental. 2015;19(4):369–75. Portuguese
  • 23
    Otter JA, Yezli S, French GL. The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol. 2011;32(7):687–99.
  • 24
    Rutala WA, Weber DJ. Are room decontamination units needed to prevent transmission of environmental pathogens? Infect Control Hosp Epidemiol. 2011;32(8):743–7.
  • 25
    Arroyo MG, Ferreira AM, Frota OP, Rigotti MA, de Andrade D, Brizzotti NS, et al. Effectiveness of ATP bioluminescence assay for presumptive identification of microorganisms in hospital water sources. BMC Infect Dis. 2017;17(1):458.
  • 26
    Anderson DJ, Moehring RW, Weber DJ, Lewis SS, Chen LF, Schwab JC, et al.; CDC Prevention Epicenters Program. Effectiveness of targeted enhanced terminal room disinfection on hospital-wide acquisition and infection with multidrug-resistant organisms and Clostridium difficile: a secondary analysis of a multicentre cluster randomised controlled trial with crossover design (BETR Disinfection). Lancet Infect Dis. 2018 Aug;18(8):845–53.
  • 27
    Mitchell BG, Hall L, White N, Barnett AG, Halton K, Paterson DL, et al. An environmental cleaning bundle and health-care-associated infections in hospitals (REACH): a multicentre, randomised trial. Lancet Infect Dis. 2019;19(4):410–8.
  • 28
    Rutala WA, Weber DJ. Monitoring and improving the effectiveness of surface cleaning and disinfection. Am J Infect Control. 2016;44(5 Suppl):e69–76.
  • 29
    Doll M, Stevens M, Bearman G. Environmental cleaning and disinfection of patient areas. Int J Infect Dis. 2018;67:52–7.
  • 30
    Salimifard P, Rim D, Gomes C, Kremer P, Freihaut JD. Resuspension of biological particles from indoor surfaces: effects of humidity and air swirl. Sci Total Environ. 2017;583:241–7.
  • 31
    Kim JG, Yousef AE, Dave S. Application of ozone for enhancing the microbiological safety and quality of foods: a review. J Food Prot. 1999;62(9):1071–87.
  • 32
    Nuvolone D, Petri D, Voller F. The effects of ozone on human health. Environ Sci Pollut Res Int. 2018;25(9):8074–88.
  • 33
    Furlan MC, Ferreira AM, Rigotti MA, Guerra OG, Frota OP, Sousa AF, et al. Correlation among monitoring methods of surface cleaning and disinfection in outpatient facilities. Acta Paul Enferm. 2019;32(3):282–9.
  • 34
    Paina T, Rodrigues JN, Felippe JC, Nogueira PC, Paiva SM. Conhecimento de auxiliares de higienização sobre limpeza e desinfecção relacionados à infecção hospitalar. Rev Enferm UFSM. 2015;5(1):121–30.
  • 35
    Weber DJ, Kanamori H, Rutala WA. ‘No touch’ technologies for environmental decontamination: focus on ultraviolet devices and hydrogen peroxide systems. Curr Opin Infect Dis. 2016;29(4):424–31.

Publication Dates

  • Publication in this collection
    05 May 2021
  • Date of issue
    2021

History

  • Received
    17 Sept 2019
  • Accepted
    20 Aug 2020
Escola Paulista de Enfermagem, Universidade Federal de São Paulo R. Napoleão de Barros, 754, 04024-002 São Paulo - SP/Brasil, Tel./Fax: (55 11) 5576 4430 - São Paulo - SP - Brazil
E-mail: actapaulista@unifesp.br