Does the Use of Surface Electromyography Could Improve Quality of Life among Patients Rehabilitated by Mandibular Overdentures on Different Attachments?

Abstract

Objective:

To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems.

Material and Methods:

Forty-eight patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient.

Results:

No statistically meaningful differences were noted regarding patients’ distribution among groups considering age (p>0.05) and gender (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores. The most prominent inter-correspondences were noted specifically between longevity of denture service and elevation of scores within “Functional limitation” (r=0.61; p<0.05), “Physical pain” (r=0.51; p<0.05) and “Physical disability” (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters.

Conclusion:

Significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyography-based alignment.

Keywords:
Dental Implantation; Dental Prosthesis, Implant-Supported; Quality of Life

Introduction

Dental implants significantly improve quality of life among patients rehabilitated with implant-supported overdentures comparedcompared to the outcomes registered among conventional full removable dentures users [1[1] Fernandez-Estevan L, Selva-Otaolaurruchi EJ, Montero J, Sola-Ruiz F. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: retrospective study of a cohort of edentulous patients. Med Oral Patol Oral Cir Bucal 2015; 20(4):e450-8. https://doi.org/10.4317/medoral.20498
https://doi.org/10.4317/medoral.20498...
]. Moreover, patients rehabilitated by implant-supported overdentures reported a higher level of oral satisfaction, which was indirectly associated with their scaled-up contentedness regarding obtained treatment results [1[1] Fernandez-Estevan L, Selva-Otaolaurruchi EJ, Montero J, Sola-Ruiz F. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: retrospective study of a cohort of edentulous patients. Med Oral Patol Oral Cir Bucal 2015; 20(4):e450-8. https://doi.org/10.4317/medoral.20498
https://doi.org/10.4317/medoral.20498...
]. Systematic review highlighted the superiority of non-splinted mandibular overdentures for dental rehabilitation of patients with full edentulism compared to conventional complete dentures due to the obtained efficiency levels, satisfaction grades and quality of life parameters [2[2] Kutkut A, Bertoli E, Frazer R, Pinto-Sinai G, Hidalgo RF, Studts J. A systematic review of studies comparing conventional complete denture and implant retained overdenture. J Prosthodont Res 2018; 62(1):1-9. https://doi.org/10.1016/j.jpor.2017.06.004
https://doi.org/10.1016/j.jpor.2017.06.0...
].

Results of previous studies demonstrated that registered level of masticatory performance obtained after prosthetic treatment was related not only with objective influential factors (number of residual teeth and occlusal units) but also with several subjectively affiliated values (mastication satisfaction, impact on quality of life and masticatory ability) [3[3] Palomares T, Montero J, Rosel EM, Del-Castillo R, Rosales JI. Oral health-related quality of life and masticatory function after conventional prosthetic treatment: A cohort follow-up study. J Prosthet Dent 2018; 119(5):755-63. https://doi.org/10.1016/j.prosdent.2017.07.023
https://doi.org/10.1016/j.prosdent.2017....
]. Based on that, it may be resumed that not only functionally registered or instrumentally diagnosed criteria may be applicable for grading results of prosthetic rehabilitation with implant-supported overdentures, but quality of life parameter in different ways also represents individually oriented criteria of treatment success among patients with full edentulism.

Nevertheless, in the review published in Cochrane Database of Systematic Reviews, it was stated that there is a deficiency of evidence regarding relative effectiveness of different attachment systems used for implant-supported overdentures in means of such criteria as patient’s satisfaction and preferences, maintenance need and cost-performance ratio [4[4] Payne AG, Alsabeeha NH, Atieh MA, Esposito M, Ma S, El-Wegoud MA. Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws. Cochrane Database Syst Rev 2018; 10(10):CD008001. https://doi.org/10.1002/14651858.CD008001.pub2
https://doi.org/10.1002/14651858.CD00800...
]. Considering tremendous changes in dental status among patients who transferred from full edentulism state to implant-based rehabilitated state, there is an on-going need for complex treatment optimization, which would support accelerated patient adaptation to the new functional possibilities [5[5] Al Omoush SA, El Manaseer WR, Al Soleihat F, Jamani KD. Subjective assessment of satisfaction degree and psychosocial status of patients with highly atrophic mandible treated by implant-retained over-denture. Med Leg Update 2021; 21(1):886-92. https://doi.org/10.37506/mlu.v21i1.2429
https://doi.org/10.37506/mlu.v21i1.2429...
,6[6] Borges GA, Barbin T, Dini C, Maia LC, Magno MB, Barão VA, Mesquita MF. Patient-reported outcome measures and clinical assessment of implant-supported overdentures and fixed prostheses in mandibular edentulous patients: a systematic review and meta-analysis. J Prosthet Dent 2020; S0022-3913(20)30694-6. https://doi.org/10.1016/j.prosdent.2020.11.005
https://doi.org/10.1016/j.prosdent.2020....
]. Surface electromyography represents an effective method used for the normalization of masticatory muscle balance with different treatment objectives [7[7] Grunert I, Kofler M, Gausch K, Kronenberg M. Masseter and temporalis surface electromyography in patients wearing complete dentures comparing anterior and posterior occlusal concepts - a pilot study. J Oral Rehabil 1994; 21(3):337-47. https://doi.org/10.1111/j.1365-2842.1994.tb01148.x
https://doi.org/10.1111/j.1365-2842.1994...
,8[8] Ranganathan S. A comparative evaluation of patient's satisfaction and quality of life and masticatory efficiency with conventional complete denture, single and double implant retained mandibular overdenture using a surface electromyography-An in vivo study. J Indian Prosthodont Soc 2020; 20(5):15-6. https://doi.org/10.4103/0972-4052.306339
https://doi.org/10.4103/0972-4052.306339...
,9[9] de Caxias FP, Túrcio KH, Neto CL, de Athayde FR, Goiato MC, Dos Santos DM. Effects of rehabilitation with complete dentures on bite force and electromyography of jaw and neck muscles and the correlation with occlusal vertical dimension. Clin Oral Investig 2021; 25(7):4691-8. https://doi.org/10.1007/s00784-021-03783-1
https://doi.org/10.1007/s00784-021-03783...
], but there is a lack of literature data regarding implementation of such an approach specifically into clinical implant practice.

The null hypothesis was formulated as follows: correction of masticatory muscles balance under surface electromyography supervision during implant overdenture try-in phase would not affect the outcome of using overdentures with Locator and ball attachments in means of quality of life parameters changes among dental patients.

To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems while controlling masticatory muscles balance using surface electromyography.

Material and Methods

Study Design and Sample Formation

The research was designed a longitudinal study provided on the base of University Dental Clinic (Uzhhorod National University, Faculty of Dentistry, Uzhhorod, Ukraine). The patients' cohort was formed out of a number of dental patients who presented with full mandibular edentulism requiring prosthetic rehabilitation using implant-supported overdenture. Following parameters were used as inclusion criteria during realization of study: 1) age of patients over 18 years (minimally required age for legal agreement to participate in the clinical study); 2) full mandibular edentulism; 3) presence of natural teeth or any kind of fixed denture at the maxilla that support normal functioning of maxillary dentition; 4) absence of any somathopathologies that potentially could compromise outcome of implant treatment; 5) sufficient amount of bone volume within the mental region for implant placement; 6) ongoing use of conventional full removable denture at mandible; 7) personal agreement of patient evidenced by patients signed consent form to take part in the present study considering all aspects of its design. Exclusion criteria included: 1) full maxilla edentulism; 2) single teeth presented on maxilla, amount of which compromise normal maxillary dentition functioning; 3) presence of full or partial removable denture on the maxilla; 3) presence of any allied pathology or habit that may compromise the result of implant osseointegration; 4) deficiency of bone volume within the projection of future implant placement that requires bone augmentation procedure; 5) disagreement of the patient to take part in the study due to the personal non-compliance with some of the study design aspects.

Considering specific inclusion and exclusion criteria, 48 patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All implants placement procedures were provided by the same experienced surgeon properly certified for implant treatment. Right after implant installation, healing abutments were placed over intraosseous fixture, and full mandibular dentures that were previously used by patients were adapted using resilient liner [10[10] Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J of Prosthodont 2012; 25(4):392-4.,11[11] Miler AM, Correia AR, Rocha JM, Campos JC, da Silva MH. Locator® attachment system for implant overdentures: a systematic review. Stomatologija 2017; 19(4):124-9.,12[12] Büttel AE, Bühler NM, Marinello CP. Locator or ball attachment: a guide for clinical decision making. Schweiz Monatsschr Zahnmed 2009; 119(9):901-18.,13[13] Rosa CD, de Souza Leão R, Guerra CM, Pellizzer EP, da Silva Casado BG, de Moraes SL. Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial. Saudi Dent J 2021; 33(6):299-307. https://doi.org/10.1016/j.sdentj.2021.03.002
https://doi.org/10.1016/j.sdentj.2021.03...
].

Three months after the surgical phase of rehabilitation, either Locator- or ball-attachments were installed over previously placed implant screws. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Distribution of patients between Locator- and ball-attachments groups was based on the personal patient's agreement regarding the use of different attachments designs while taking into account specific features of each analyzed clinical situation, financial aspects and technical issues. Due to the above-mentioned factors, Locator-attachment group was formed out of 28 patients and ball-attachment group – out of 20 patients. Height of abutment was chosen due to the present thickness of surrounding soft tissue, and males' part was chosen considering measured angulation of each inserted implant [10[10] Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J of Prosthodont 2012; 25(4):392-4.,12[12] Büttel AE, Bühler NM, Marinello CP. Locator or ball attachment: a guide for clinical decision making. Schweiz Monatsschr Zahnmed 2009; 119(9):901-18.]. Processing of denture caps into the overdenture was held by the direct method following manufacturer's instruction [10[10] Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J of Prosthodont 2012; 25(4):392-4.,12[12] Büttel AE, Bühler NM, Marinello CP. Locator or ball attachment: a guide for clinical decision making. Schweiz Monatsschr Zahnmed 2009; 119(9):901-18.] (Figure 1A-E).

Figure 1
(A) Installed ball-attachments; (B) Implant-based overdenture designed for ball-attachments; (C) Installed Locator-attachments; (D) Locator-attachments; and (E) Implant-based overdenture designed for Locator-attachments.

The prosthetic phase of rehabilitation included the formation of bilateral balanced occlusion. But in each group, half of patients were randomly assigned for the surface electromyography controlling procedure during denture construction try-in with further denture occlusal correction for reaching the most balanced correspondence between left and right temporal and masticatory muscles. Surface electromyography evaluation was provided with the use of a Teethan device (BTS S.p.A., Garbagnate Milanese, Italy) due to the previously described protocol with analysis of such targeted parameters as the symmetry of contraction within homological pair of masticatory muscles (POC-index), asymmetry between left and right sides (ASIM-index), and mandibular torsion index (TORS-index) [14[14] Tecco S, Cattoni F, Darvizeh A, Bosco F, Sanci V, Nota A, et al. Evaluation of masticatory muscle function using digital versus traditional techniques for mockup fabrication: a controlled prospective study. Appl Sci 2020; 10(17):6013. https://doi.org/10.3390/app10176013
https://doi.org/10.3390/app10176013...
]. Normalization of above-mentioned parameters by occlusal correction supports an establishment of approximal equilibrium between left and right sides temporal and masseter muscles.

Another half of patients in each group was not undergoing above-mentioned procedure and correction of occlusal interrelation among them was done due to the results of bite tracing with articulating paper. This way, four final groups were formed: Locator-attachment SE (Group 1A) (group of patients with overdentures installed over Locator-attachments among which occlusal correction was held under the control of surface electromyography) – 14 patients, Locator-attachment non-SE (Group 1B) group (group of patients with overdenture installed over Locator-attachments among which occlusal correction was held due to the results of bite tracing with articulating paper) – 14 patients, ball-attachment SE (Group 2A) group (group of patients with overdenture installed over ball-attachments among which occlusal correction was held under the control of surface electromyography) – 10 patients, and ball-attachment non-SE (Group 2B) (group of patients with overdenture installed over ball-attachments among which occlusal correction was held due to the results of bite tracing with articulating paper) – 10 patients.

Data Collection

Before receiving any intervention, each patient from the study cohort was evaluated with the use of OHIP-EDENT questionnaire to verify how the translation from conventional removable denture to the implant-retained overdenture could potentially improve oral health-related quality of life (OHRQoL) under the conditions of using attachments of different design and implementing different approaches for occlusal correction.

Repeated evaluation of oral health-related quality of life (OHRQoL) was provided also 1 month and 12 months after definitive overdenture placement. OHIP-EDENT questionnaire composed of 19 questions categorized within seven domains, which include Functional Limitation (3 questions), Physical Pain (4 questions), Psychological Discomfort (2 questions), Physical Disability (3 questions), Psychological Disability (2 questions); Social Disability (3 questions), Handicap (2 questions) [15[15] Possebon AP, Faot F, Machado RM, Nascimento GG, Leite FR. Exploratory and confirmatory factorial analysis of the OHIP-Edent instrument. Braz Oral Res 2018; 32:e111. https://doi.org/10.1590/1807-3107bor-2018.vol32.0111
https://doi.org/10.1590/1807-3107bor-201...
,16[16] Souza RF, Leles CR, Guyatt GH, Pontes CB, Della Vecchia MP, Neves FD. Exploratory factor analysis of the Brazilian OHIP for edentulous subjects. J Oral Rehabil 2010; 37(3):202-8. https://doi.org/10.1111/j.1365-2842.2009.02043.x
https://doi.org/10.1111/j.1365-2842.2009...
,17[17] Mahanna FF, Elsyad MA, Mourad SI, Abozaed HW. Satisfaction and oral health-related quality of life of different attachments used for implant-retained overdentures in subjects with resorbed mandibles: a crossover trial. Int J Oral Maxillofac Implants 2020; 35(2):423-31. https://doi.org/10.11607/jomi.7869
https://doi.org/10.11607/jomi.7869...
]. All 19 questions were reproduced from an originally developed questionnaire and translated into Ukrainian. Respondents answered each question to specify the frequency of each functional, social or emotional limitation occurring (5 points Likert scale): 0 – never, 1 – seldom, 2 – sometimes, 3 – fairly often, 4 – very often). As a result, range of possible summed OHIP-EDENT scores received among different domains varies between 0 and 76 points, while the higher summed value represents the lower grading for quality of life related to the condition of oral status [15[15] Possebon AP, Faot F, Machado RM, Nascimento GG, Leite FR. Exploratory and confirmatory factorial analysis of the OHIP-Edent instrument. Braz Oral Res 2018; 32:e111. https://doi.org/10.1590/1807-3107bor-2018.vol32.0111
https://doi.org/10.1590/1807-3107bor-201...
,16[16] Souza RF, Leles CR, Guyatt GH, Pontes CB, Della Vecchia MP, Neves FD. Exploratory factor analysis of the Brazilian OHIP for edentulous subjects. J Oral Rehabil 2010; 37(3):202-8. https://doi.org/10.1111/j.1365-2842.2009.02043.x
https://doi.org/10.1111/j.1365-2842.2009...
,17[17] Mahanna FF, Elsyad MA, Mourad SI, Abozaed HW. Satisfaction and oral health-related quality of life of different attachments used for implant-retained overdentures in subjects with resorbed mandibles: a crossover trial. Int J Oral Maxillofac Implants 2020; 35(2):423-31. https://doi.org/10.11607/jomi.7869
https://doi.org/10.11607/jomi.7869...
].

Additionally, satisfaction with outcome oral status condition was measured by Oral Satisfaction Scale (OSS), which accompanied OHIP-EDENT to stratify patients’ self-assessment of well-being regarding oral changes [18[18] Montero J, Bravo M, Albaladejo A. Validation of two complementary oral-health related quality of life indicators (OIDP and OSS 0-10) in two qualitatively distinct samples of the Spanish population. Health Qual Life Outcomes 2008; 6(1):1-4. https://doi.org/10.1186/1477-7525-6-101
https://doi.org/10.1186/1477-7525-6-101...
]. In the present study, we used a modified Oral Satisfaction Scale that included the following aspects: provided implant treatment, provided prosthetic manipulation, chewing ability, adaptation to overdenture, phonetic function, esthetic parameters, comfort, hygiene maintenance of the denture, technical maintenance of the denture. In addition, 1-10 points grading scale was used for the evaluation of above-mentioned aspects, with 1 representing total dissatisfaction and 10 standing for full satisfaction with received outcome. OSS evaluation was provided before any intervention during patient’s usage of conventional full removable denture and 1 and 12 months after final overdenture placement among all groups.

The chewing ability of patients was measured with the use of chewing ability index (ICA) developed previously by Leake [19[19] Bortoluzzi MC, Traebert J, Lasta R, Da Rosa TN, Capella DL, Presta AA. Tooth loss, chewing ability and quality of life. Contemp Clin Dent 2012; 3(4):393-7. https://doi.org/10.4103/0976-237X.107424
https://doi.org/10.4103/0976-237X.107424...
,20[20] Leake JL. An index of chewing ability. J Public Health Dent 1990; 50(4):262-7. https://doi.org/10.1111/j.1752-7325.1990.tb02133.x
https://doi.org/10.1111/j.1752-7325.1990...
]. Methodology of index calculation based on patient’s answer dichotomy of “Yes” or “No” on five questions regarding the possibility to adequately chew 5 types of food: fresh carrot/celery sticks, fresh lettuce/spinach salad, steaks, chops of firm meat, boiled peas, carrots or green/yellow beans, whole fresh apple without cutting it. If the person can answer “Yes” on all 5 questions, that final score of 5 indicates full chewing competence, while even one “No” answer with a total score equal or lower than 4 indicates deficient chewing ability [19[19] Bortoluzzi MC, Traebert J, Lasta R, Da Rosa TN, Capella DL, Presta AA. Tooth loss, chewing ability and quality of life. Contemp Clin Dent 2012; 3(4):393-7. https://doi.org/10.4103/0976-237X.107424
https://doi.org/10.4103/0976-237X.107424...
,20[20] Leake JL. An index of chewing ability. J Public Health Dent 1990; 50(4):262-7. https://doi.org/10.1111/j.1752-7325.1990.tb02133.x
https://doi.org/10.1111/j.1752-7325.1990...
].

Data Analysis

The reliability of the registered differences (p) was estimated in accordance with the generally accepted statistical methods, using the Student's t-criterion for parametrical variables and Mann-Whitney’s U-test for nonparametric variables. Registered outcomes were categorized as significant only when p<0.05 (significance level of 0.95). Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient [21[21] Bowers D. Medical Statistics From Scratch: An Introduction for Health Professionals. London: John Wiley & Sons; 2019.,22[22] Everitt BS. Medical Statistics From A to Z: A Guide for Clinicians and Medical Students. Cambridge University Press; 2021.]. Obtained correlation levels were interpreted by the Chaddock scale: 0 < r < 0.1 – non-significant regression, 0.1 < r < 0.3 – weak regression, 0.3 < r < 0.5 – moderate regression, 0.5 < r < 0.7 – noticeable regression, 0.7 < r < 0.9 – close regression, 0.9 < r < 0.99 – strong regression, 0.99 < r < 0.1 – functional regression [23[23] Mukaka MJ. Statistics corner: a guide to appropriate use of correlation in medical research. Malawi Med J 2012; 24(3):69-71.]. Regression analysis was provided regarding OHIP-EDENT, OSS and CAI changes before implant treatment, and 1 and 12 months after overdenture delivery due to their potential interdependences and possible impact of muscle-based occlusion calibration on above-mentioned parameters. Statistical analysis of the obtained data was provided within Microsoft Excel software (Microsoft Office 2019, Microsoft Corp., USA) with the additional use of add-ins, such as Analyse-it (Analyse-it Software, Ltd., Leeds, UK) and XLSTAT (Addinsoft Inc., Long Island, NY, USA).

Ethical Aspects

The study protocol was approved by the Ethics Committee of Faculty of Dentistry at Uzhhorod National University (Uzhhorod, Ukraine) with received number of EC 14022019 (14/02/2019). All patients recruited in the study voluntarily agreed to participate in the clinical survey after a detailed explanation of all study design aspects, evidenced with a signed informed consent form.

Results

Distribution of patients primarily enrolled within specifically formed groups regarding age, gender and service time of previously used mandibular conventional full removable denture represented in Table 1.

Table 1.
Distribution of patients among study groups considering parameters of age, gender and service time of mandibular conventional full removable denture.

No statistically meaningful differences were noted regarding patients’ distribution among groups considering age (p>0.05) (with general tendency of greater amount of 55-59 years old patients participated) and gender (p>0.05) criteria (with general tendency of greater number of male patients involved), even though some deviations were noted while comparing Group 1A and 2B. Nevertheless, based on provided statistical analysis, registered quantitative divergencies could not be interpreted as principal ones during inter-groups comparison. For example, most patients were using full removable mandibular dentures for the 1-3 years period, while no statistical difference was noted during comparative analysis of “Service years of conventional removable partial denture” parameter between different groups (p>0.05).

Two patients from Group 1A and one person from Group 2A were lost during long-term monitoring for an unknown principal reason (ignored invitation to come for control check-up after 12 months of implant overdenture service); because of this reason, they were excluded from the further analysis.

While using conventional mandibular full removable dentures, patients within all groups were characterized with a compromised level of Oral Health-Related Quality of Life levels with no registered differences between groups (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores by the meaning of correlation equal to r=0.52 (p<0.05). The most prominent inter-correspondences were noted specifically between longevity of denture service and elevation of scores within “Functional limitation” (r=0.61; p<0.05), “Physical pain” (r=0.51; p<0.05) and “Physical disability” (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters.

Provided analysis revealed a statistically significant reduction of general OHIP-EDENT scores and also at the level of each subdomain within all groups after 1 month of implant overdenture functioning while comparing it with primary registered OHIP-EDENT levels before intervention: Group 1A – 10.9±5.3 vs. 34.0±6.8 (p<0.05), Group 1B – 13.9±3.7 vs. 35.5±7.2 (p<0.05), Group 2A – 12.8±4.5 vs. 34.8±6.9 (p<0.05), Group 2B – 15.5±4.8 vs. 35.5±5.9 (p<0.05), with no differences noted between Locator-attachment and ball-attachment users (p>0.05) (Table 2).

Table 2.
Comparison of OHIP-EDENT subdomains scores before and one month after treatment.

The most prominent, but still not statistically reasoned differences between the group of patients with provided procedure of occlusal correction due to the surface electromyography control and group of patients occlusal correction among which was realized with the use of articulating paper, were noted at the subdomains “Ill-fitting denture” (0.7±0.6 vs. 1.1±0.4 at the Locator-attachment group 1A and 1B respectively; 0.9±0.6 vs. 1.4±0.5 at the ball-attachment group 2A and 2B, respectively) and “Uncomfortable denture” (0.8±0.3 vs. 1.2±0.4 at the Locator-attachment group 1A and 1B, respectively; 0.9±0.4 vs. 1.4±0.3 at the ball-attachment group 2A and 2B, respectively).

After one year of service, no statistically differences regarding OHIP-EDENT values were noted neither between the group of patients with provided procedure of occlusal correction due to the surface electromyography control and group of patients occlusal correction among which was realized with the use of articulating paper (p>0.05); nor between group of patients with installed overdentures upon Locator-attachments and group of patients with placed overdentures upon ball-attachments (p>0.05). Obtained OHIP-EDENT levels were statistically lower compared to those registered during the use of conventional full removable denture before implant treatment (p<0.05) and similar to those gained after 1 month of implant overdenture functioning (p>0.05) (Table 3).

Table 3.
OHIP-EDENT domains values 12 months after treatment.

Due to the results obtained with Oral Satisfaction Scale as a measurement of subjective satisfaction with treatment outcome patients with occlusal control provided via surface electromyography procedure demonstrated higher OSS values of “Adaptation to overdenture” (p<0.05) and “Comfort” (p<0.05) after 1 month of overdenture functioning compare to the patients occlusal correction among which was provided via classical algorithms by the use of articulating paper (Table 4).

Table 4.
Oral Satisfaction Scale results from one month after treatment.

No differences were noted regarding any parameter of OSS neither between the group of patients with provided procedure of occlusal correction due to the surface electromyography control and group of patients occlusal correction among which was realized with the use of articulating paper (p>0.05); nor between group of patients with installed overdentures upon Locator-attachments and group of patients with placed overdentures upon ball-attachments (p>0.05) at the 12 months control check-up (despite the fact that matrix-related events of denture technical-maintenance were registered more frequently among ball-attachments users). Technical maintenance issues in form of matrix and/or patrix-related events were noted with a prevalence of 7.69% among patients with Locator-attachments and 10.52% among patients with ball-attachments after 12 months of implant overdentures service. Even when considering some frequency of technical maintenance issues occurrence among all study groups, level of subjective satisfaction by OSS after 1 year of implant overdentures functioning was more than 8 points average based on all studied parameters (provided implant treatment, provided prosthetic manipulation, adaptation of overdenture, phonetic function, esthetic parameters, comfort, hygiene maintenance of the denture and technical maintained of the denture).

Due to Chewing Ability Index interpretation usage of conventional mandibular complete removable denture provoked deficient chewing ability among all 100% of patients, while after 1 year of implant overdenture functioning, only 33.33% of patients reported inability to chew some specific type of food. Prevalence of patients with deficient chewing ability demonstrated decreased tendency while comparing results registered 1 month and 12 months after placing overdenture (52.08% vs. 33.33%). Variations of CAI values at the patient level demonstrated no statistically interrelation neither with fact of Locator- (p>0.05) or ball-attachment (p>0.05) use, nor with the fact of providing procedure of occlusal correction under surface electromyography guidance or through articulating paper tracing (p>0.05).

Discussion

Implant-based prosthetic rehabilitation of patients with full edentulism represents an effective treatment option for chewing ability restoration and resolution of functional and physiological disabilities [1[1] Fernandez-Estevan L, Selva-Otaolaurruchi EJ, Montero J, Sola-Ruiz F. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: retrospective study of a cohort of edentulous patients. Med Oral Patol Oral Cir Bucal 2015; 20(4):e450-8. https://doi.org/10.4317/medoral.20498
https://doi.org/10.4317/medoral.20498...
,2[2] Kutkut A, Bertoli E, Frazer R, Pinto-Sinai G, Hidalgo RF, Studts J. A systematic review of studies comparing conventional complete denture and implant retained overdenture. J Prosthodont Res 2018; 62(1):1-9. https://doi.org/10.1016/j.jpor.2017.06.004
https://doi.org/10.1016/j.jpor.2017.06.0...
,4[4] Payne AG, Alsabeeha NH, Atieh MA, Esposito M, Ma S, El-Wegoud MA. Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws. Cochrane Database Syst Rev 2018; 10(10):CD008001. https://doi.org/10.1002/14651858.CD008001.pub2
https://doi.org/10.1002/14651858.CD00800...
,6[6] Borges GA, Barbin T, Dini C, Maia LC, Magno MB, Barão VA, Mesquita MF. Patient-reported outcome measures and clinical assessment of implant-supported overdentures and fixed prostheses in mandibular edentulous patients: a systematic review and meta-analysis. J Prosthet Dent 2020; S0022-3913(20)30694-6. https://doi.org/10.1016/j.prosdent.2020.11.005
https://doi.org/10.1016/j.prosdent.2020....
,24[24] Goncharuk-Khomyn M, Andrii K. Evaluation of peri-implant bone reduction levels from superimposition perspective: pilot study among Ukrainian implantology practice. Pesqui Bras Odontopediatria Clin Integr 2018; 18(1):3856. https://doi.org/10.4034/PBOCI.2018.181.10
https://doi.org/10.4034/PBOCI.2018.181.1...
]. Moreover, rehabilitation of edentulous patients with implant-supported overdentures also decreases the risk of malnutrition among patients aged 60 years and older compared to the outcomes registered during the use of conventional removable prosthetic constructions [25[25] El Osta N, El Osta L, Moukaddem F, Papazian T, Saad R, Hennequin M, Khabbaz LR. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients. Clin Nutr ESPEN 2017; 18:49-54. https://doi.org/10.1016/j.clnesp.2017.01.001
https://doi.org/10.1016/j.clnesp.2017.01...
]. Nevertheless, there are still relevant issues that argue the need for further treatment protocol optimization regarding patients' adaptation to the overdenture design, occlusal scheme modification, technical maintenance aspects, and personal satisfaction with obtained outcome [10[10] Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J of Prosthodont 2012; 25(4):392-4.,11[11] Miler AM, Correia AR, Rocha JM, Campos JC, da Silva MH. Locator® attachment system for implant overdentures: a systematic review. Stomatologija 2017; 19(4):124-9.,13[13] Rosa CD, de Souza Leão R, Guerra CM, Pellizzer EP, da Silva Casado BG, de Moraes SL. Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial. Saudi Dent J 2021; 33(6):299-307. https://doi.org/10.1016/j.sdentj.2021.03.002
https://doi.org/10.1016/j.sdentj.2021.03...
].

Considering the outreached results of present study, formulated null hypothesis could be approved since correction of masticatory muscles balance under surface electromyography supervision during implant overdenture try-in phase had not affected the long-term service outcome of overdentures based either at Locator- or ball-attachments in means of quality of life parameters among dental patients. In 12 months perspective usage of surface electromyography for masticatory muscle balance during prosthetic try-in phase, or support of overdentures by either Locator- or ball-attachments, demonstrated no statistically argumented impact on the variations of quality of life values. The only statistical difference registered among groups was noted at 1-month control period while comparing derivates of Oral Satisfaction Scale, due to which it could be presumed that equilibration of masticatory muscles by occlusal correction under the guidance of surface electromyography supports quicker patient’s adaptation to overdenture and associated with higher comfort in a short-term perspective.

Compared to the conventional removable dentures, all kinds of attachments used with mandibular overdentures demonstrated significant improvement within OHRQoL and patient satisfaction levels, nevertheless when compares between each other different types of attachments are characterized with different clinical, biomechanical and biological advantages and issues [26[26] Elsyad MA, Mahanna FF, Elshahat MA, Elshoukouki AH. Locators versus magnetic attachment effect on peri-implant tissue health of immediate loaded two implants retaining a mandibular overdenture: a 1-year randomised trial. J Oral Rehabil 2016; 43(4):297-305. https://doi.org/10.11607/jomi.7484
https://doi.org/10.11607/jomi.7484...
]. Positive effect on quality of life during the service of overdentures with a different type of attachments was registered among patients irrespectively to the type of implemented retention system, age and gender-based on outcome obtained with OHIP-49 questionnaire [27[27] Kucukkurt S, Özturk C. Comparison of the effects of two different types of retainers used in implant-supported overdenture prosthesis on patient satisfaction. Yeditepe Dent J 2020; 16(1):74-80. https://doi.org/10.5505/yeditepe.2020.71676
https://doi.org/10.5505/yeditepe.2020.71...
]. Due to the results obtained in a systematic review provided by Chaware and Thakkar [28[28] Chaware SH, Thakkar ST. A systematic review and meta-analysis of the attachments used in implant-supported overdentures. J Indian Prosthodont Soc 2020; 20(3):255-268. https://doi.org/10.4103/jips.jips_368_19
https://doi.org/10.4103/jips.jips_368_19...
] ball- and Locator-attachments were characterized with relatively analogically high survival rates, patient’s satisfaction levels and tissue responses during the monitoring for 3 years of functioning. Similar findings were also registered within our study: it was found that the use of implant-based overdentures have improved both quality of life and oral satisfaction parameters among patients compared to the results registered among them during the use of conventional full removable dentures. Moreover, regarding OHIP-EDENT values and OSS scores, no difference was found between Locator- and ball-attachments users.

In Matthys et al. [29[29] Matthys C, Vervaeke S, Besseler J, Doornewaard R, Dierens M, De Bruyn H. Five years follow-up of mandibular 2-implant overdentures on locator or ball abutments: Implant results, patient-related outcome, and prosthetic aftercare. Clin Implant Dent Relat Res 2019; 21(5):835-44. https://doi.org/10.1111/cid.12840
https://doi.org/10.1111/cid.12840...
] study, it was found that even though both Locator- and ball-attachments were associated with improvements within Oral Health Related Quality of Life (OHRQoL), but clinical cases with Loc-types attachments demonstrated a higher frequency of retention correction need, thus affecting QOL through the impact of additional expenses due to the maintenance issues. On the other hand, Brandt et al. [30[30] Brandt S, Lauer HC, Fehrenz M, Güth JF, Romanos G, Winter A. Ball versus Locator® attachments: a retrospective study on prosthetic maintenance and effect on oral-health-related quality of life. Materials 2021; 14(4):1051. https://doi.org/10.3390/ma14041051
https://doi.org/10.3390/ma14041051...
] found that ball-attachments were associated with a higher need of maintenance during monitoring period, while in most cases, maintenance measures for both ball- and locator-attachments included matrix-related corrections. Within present study, technical maintenance issues in the form of matrix and/or patrix-related events were characterized with a higher level of prevalence among ball-attachments users, but no statistical difference was noted while comparing the need of maintenance measures among both Locator- and ball-attachments users (p>0.05). Such outcomes are aligning with results of in vitro study, which demonstrated that ball- and Locator-attachments present no statistically significant differences regarding wear level and technical functioning after 5000 insertion-separation cycles, while retentive properties of such were statistically lower compared to the primary situation in both cases [31[31] Eren Türk P, Geckili O, Türk Y, Günay V, Bilgin T. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures. Int J Oral Maxillofac Implants 2014; 29(5):1106-13. https://doi.org/10.11607/jomi.3621
https://doi.org/10.11607/jomi.3621...
]. After the realization of 5000 in-out cycles, Locator-attachment were characterized with relatively higher residual retentive characteristics compared to ball-attachments [31[31] Eren Türk P, Geckili O, Türk Y, Günay V, Bilgin T. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures. Int J Oral Maxillofac Implants 2014; 29(5):1106-13. https://doi.org/10.11607/jomi.3621
https://doi.org/10.11607/jomi.3621...
].

Amount of previous studies demonstrated that the type of used attachment system does not significantly influence masticatory muscles activity pattern. In most researches, registered differences within EMG-parameters were not statically approved, even though some studies had shown preferences for some specific type of attachment. Due to the previous study, patients with overdentures on Locator-attachments were characterized with higher amplitude of masseter and temporalis muscles than the users of complete conventional dentures, but general tendency of masseter and temporalis muscles activity increase was noted in both groups of patients with advance of time [32[32] Hassan SS, Helmy MH. Implant supported mandibular overdentures with Locator attachments in patients with resorbed mandibular ridges. A cross over study of patient satisfaction and oral health related quality of life. Egypt Dent J 2020; 66:671-81. https://doi.org/10.21608/EDJ.2020.79139
https://doi.org/10.21608/EDJ.2020.79139...
]. In the study of Abdelhamid et al., it was noted that the use of Locator-attachments demonstrated higher masticatory function outcomes in means of muscle activity [33[33] Abdelhamid AM, Metwally NA, Imam MH. The effect of two different attachments with implant retained mandibular overdentures on the masticatory function. J Dent Health Oral Disord Ther 2016; 4(2):38-45. https://doi.org/10.15406/jdhodt.2016.04.00101
https://doi.org/10.15406/jdhodt.2016.04....
]. Results of previously provided randomized controlled trial demonstrated that during short-term monitoring the highest level of muscles activity was noted after attachment of mandibular dentures onto Locator-abutments, while in long-term perspective, statistical difference between groups with Locator- and ball-attachments in means of muscle activity was not noted [34[34] Abdel-Bary SK, Alameldeen HE. Electromyographic evaluation of implant overdenture retained by two different types of attachments (randomized control trial). Egypt Dent J 2019; 65(4):3751-61. https://doi.org/10.21608/EDJ.2019.76021
https://doi.org/10.21608/EDJ.2019.76021...
]. In another study, two implant supported overdentures with the use of ball-attachment system demonstrated higher values of EMG masticatory muscles amplitude, chewing area and duration of chewing cycle compared to the bar and Locator attachments, while all three of them supported more advanced muscle functioning compared to the conventional removable dentures [35[35] Elsyad MA, Ibrahim AE, Nawar NH, Belal TM. Electromyographic connectivity of masseter muscle with different retentive attachments for implant overdentures in patients with atrophied mandibular ridges: a crossover study. Int J Oral Maxillofac Implants 2019; 34(5):1213-22. https://doi.org/10.11607/jomi.7484
https://doi.org/10.11607/jomi.7484...
]. Data obtained in a randomized controlled study found a correlation between improvement of masticatory efficiency and positive changes within OHIP scores, which was argumented by the fact that OHIP represents subjective grading of quality of life improvement, which in turn also depends on proper mastification function [36[36] Sun X, Zhai JJ, Liao J, Teng MH, Tian A, Liang X. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures. Saudi Med J 2014; 35(10):1195-202.]. Our study revealed supportive outcomes: both Locator- and ball-attachments users demonstrated statistically significant improvement of quality of life compared to primary condition of using conventional removable dentures, while no difference regarding chewing ability was noted after one year of monitoring between Locator and ball-attachment groups. Correction of masticatory muscle balance after insertion of overdenture supported quicker patients’ adaptation to the formulated occlusal scheme. Nevertheless, the quicker adaptation effect has not significantly influenced the quality of life parameter in the long-term perspective, even though it impacted the Oral Satisfactory Score values after one month of monitoring. We have not tested surface electromyography parameters among all patients after one year of overdenture functioning because of two reasons: 1) comparison of surface electromyography parameters and their possible use for further masticatory muscles balancing through occlusal correction beneficial only at individual patient level, while it is not helpful for interpretation in group due to the prominent interpersonal variability of chewing muscles interrelation; 2) present study design was aimed at assessment of surface electromyography supervision impact during implant overdenture try-in phase on the outcome of using overdentures with Locator- and ball-attachments in means of quality of life parameter among dental patients in general, while future study will be aimed at in-detail analysis of patient-oriented parameters changes for development of customized treatment protocol.

Some differences of outcomes registered in our and previous studies could be argumented by the several factors: targeted use of surface electromyography was provided only at strict time point of overdenture try-in, but not in on-going manner during regular check-ups; relatively small study sample; usage of OHIP-EDENT form instead of other versions of oral health-related quality of life questionnaires; evaluation of null hypothesis at level of study group, but not at individual patient level. Such specifics of study design considering all above-mentioned aspects could be interpreted as its partial limitations. In the present study, we have used translated international short version of Oral Health Impact Profile for edentulous patients since there were no studies on developing Ukrainian version of OHIP-EDENT or OHIP-14. Meanwhile, an international version of OHIP-EDENT have demonstrated adequately evidenced results during verification and validation. Also, considering the results of an international multicenter study, cultural features associated with the study population influence the different domains of quality of life questionaries' in cases of rehabilitation with implant-supported overdentures [37[37] Awad MA, Rashid F, Feine JS. Overdenture effectiveness study team consortium. The effect of mandibular 2-implant overdentures on oral health-related quality of life: an international multicentre study. Clin Oral Implants Res 2014; 25(1):46-51. https://doi.org/10.1111/clr.12205
https://doi.org/10.1111/clr.12205...
].

The perspective of further study could be aimed at investigation of quality of life changes among edentulous patients through the ongoing monitoring with periodical check-ups while using surface electromyography as a routine diagnostic tool during every visit. Such an approach will support quantitative normalization and metric interpretation of quality of life parameters among patients with various dental functional alterations through the customization of treatment algorithm. Furthermore, in our future study, we will also use the value of minimal important difference parameter [1[1] Fernandez-Estevan L, Selva-Otaolaurruchi EJ, Montero J, Sola-Ruiz F. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: retrospective study of a cohort of edentulous patients. Med Oral Patol Oral Cir Bucal 2015; 20(4):e450-8. https://doi.org/10.4317/medoral.20498
https://doi.org/10.4317/medoral.20498...
], which helps evaluate such minimal changes within the score range, basically providing factual benefit and arguments the better effect of one patients' management method another.

Conclusion

The use of surface electromyography as an instrument for masticatory muscles control and their symmetrical balancing by occlusal correction support quicker adaptation of patients to the provided implant-supported overdentures with the attachments of different designs but not principally affects it. Optimization of the adaptational period to the placed overdentures by the masticatory muscles balancing was related to the improvements within oral satisfaction scale parameters during short-term monitoring of one month. Nevertheless, long-term outcomes had not demonstrated any statistically significant differences regarding maintenance and quality of life parameters among patients rehabilitated by overdentures on ball- and Locator-attachments irrespectively of surface electromyography method usage with the muscle balancing objective at the time of the dentures try-in. On the other hand, significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyography-based alignment. Therefore, it may be hypothesized that periodical control of masticatory muscle balance during follow-up visits with the use of surface electromyography method potentially could have a positive impact on appropriate quality of life level assurance, but such effect should be studied in a detailed manner during future researches, while also considering peculiarities of differently designed occlusal schemes.

  • Financial Support
    None.
  • Data Availability
    The data used to support the findings of this study can be made available upon request to the corresponding author.

References

  • [1]
    Fernandez-Estevan L, Selva-Otaolaurruchi EJ, Montero J, Sola-Ruiz F. Oral health-related quality of life of implant-supported overdentures versus conventional complete prostheses: retrospective study of a cohort of edentulous patients. Med Oral Patol Oral Cir Bucal 2015; 20(4):e450-8. https://doi.org/10.4317/medoral.20498
    » https://doi.org/10.4317/medoral.20498
  • [2]
    Kutkut A, Bertoli E, Frazer R, Pinto-Sinai G, Hidalgo RF, Studts J. A systematic review of studies comparing conventional complete denture and implant retained overdenture. J Prosthodont Res 2018; 62(1):1-9. https://doi.org/10.1016/j.jpor.2017.06.004
    » https://doi.org/10.1016/j.jpor.2017.06.004
  • [3]
    Palomares T, Montero J, Rosel EM, Del-Castillo R, Rosales JI. Oral health-related quality of life and masticatory function after conventional prosthetic treatment: A cohort follow-up study. J Prosthet Dent 2018; 119(5):755-63. https://doi.org/10.1016/j.prosdent.2017.07.023
    » https://doi.org/10.1016/j.prosdent.2017.07.023
  • [4]
    Payne AG, Alsabeeha NH, Atieh MA, Esposito M, Ma S, El-Wegoud MA. Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws. Cochrane Database Syst Rev 2018; 10(10):CD008001. https://doi.org/10.1002/14651858.CD008001.pub2
    » https://doi.org/10.1002/14651858.CD008001.pub2
  • [5]
    Al Omoush SA, El Manaseer WR, Al Soleihat F, Jamani KD. Subjective assessment of satisfaction degree and psychosocial status of patients with highly atrophic mandible treated by implant-retained over-denture. Med Leg Update 2021; 21(1):886-92. https://doi.org/10.37506/mlu.v21i1.2429
    » https://doi.org/10.37506/mlu.v21i1.2429
  • [6]
    Borges GA, Barbin T, Dini C, Maia LC, Magno MB, Barão VA, Mesquita MF. Patient-reported outcome measures and clinical assessment of implant-supported overdentures and fixed prostheses in mandibular edentulous patients: a systematic review and meta-analysis. J Prosthet Dent 2020; S0022-3913(20)30694-6. https://doi.org/10.1016/j.prosdent.2020.11.005
    » https://doi.org/10.1016/j.prosdent.2020.11.005
  • [7]
    Grunert I, Kofler M, Gausch K, Kronenberg M. Masseter and temporalis surface electromyography in patients wearing complete dentures comparing anterior and posterior occlusal concepts - a pilot study. J Oral Rehabil 1994; 21(3):337-47. https://doi.org/10.1111/j.1365-2842.1994.tb01148.x
    » https://doi.org/10.1111/j.1365-2842.1994.tb01148.x
  • [8]
    Ranganathan S. A comparative evaluation of patient's satisfaction and quality of life and masticatory efficiency with conventional complete denture, single and double implant retained mandibular overdenture using a surface electromyography-An in vivo study. J Indian Prosthodont Soc 2020; 20(5):15-6. https://doi.org/10.4103/0972-4052.306339
    » https://doi.org/10.4103/0972-4052.306339
  • [9]
    de Caxias FP, Túrcio KH, Neto CL, de Athayde FR, Goiato MC, Dos Santos DM. Effects of rehabilitation with complete dentures on bite force and electromyography of jaw and neck muscles and the correlation with occlusal vertical dimension. Clin Oral Investig 2021; 25(7):4691-8. https://doi.org/10.1007/s00784-021-03783-1
    » https://doi.org/10.1007/s00784-021-03783-1
  • [10]
    Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J of Prosthodont 2012; 25(4):392-4.
  • [11]
    Miler AM, Correia AR, Rocha JM, Campos JC, da Silva MH. Locator® attachment system for implant overdentures: a systematic review. Stomatologija 2017; 19(4):124-9.
  • [12]
    Büttel AE, Bühler NM, Marinello CP. Locator or ball attachment: a guide for clinical decision making. Schweiz Monatsschr Zahnmed 2009; 119(9):901-18.
  • [13]
    Rosa CD, de Souza Leão R, Guerra CM, Pellizzer EP, da Silva Casado BG, de Moraes SL. Do ball-type attachment systems for overdenture result in better patient-satisfaction? A systematic review of randomized crossover clinical trial. Saudi Dent J 2021; 33(6):299-307. https://doi.org/10.1016/j.sdentj.2021.03.002
    » https://doi.org/10.1016/j.sdentj.2021.03.002
  • [14]
    Tecco S, Cattoni F, Darvizeh A, Bosco F, Sanci V, Nota A, et al. Evaluation of masticatory muscle function using digital versus traditional techniques for mockup fabrication: a controlled prospective study. Appl Sci 2020; 10(17):6013. https://doi.org/10.3390/app10176013
    » https://doi.org/10.3390/app10176013
  • [15]
    Possebon AP, Faot F, Machado RM, Nascimento GG, Leite FR. Exploratory and confirmatory factorial analysis of the OHIP-Edent instrument. Braz Oral Res 2018; 32:e111. https://doi.org/10.1590/1807-3107bor-2018.vol32.0111
    » https://doi.org/10.1590/1807-3107bor-2018.vol32.0111
  • [16]
    Souza RF, Leles CR, Guyatt GH, Pontes CB, Della Vecchia MP, Neves FD. Exploratory factor analysis of the Brazilian OHIP for edentulous subjects. J Oral Rehabil 2010; 37(3):202-8. https://doi.org/10.1111/j.1365-2842.2009.02043.x
    » https://doi.org/10.1111/j.1365-2842.2009.02043.x
  • [17]
    Mahanna FF, Elsyad MA, Mourad SI, Abozaed HW. Satisfaction and oral health-related quality of life of different attachments used for implant-retained overdentures in subjects with resorbed mandibles: a crossover trial. Int J Oral Maxillofac Implants 2020; 35(2):423-31. https://doi.org/10.11607/jomi.7869
    » https://doi.org/10.11607/jomi.7869
  • [18]
    Montero J, Bravo M, Albaladejo A. Validation of two complementary oral-health related quality of life indicators (OIDP and OSS 0-10) in two qualitatively distinct samples of the Spanish population. Health Qual Life Outcomes 2008; 6(1):1-4. https://doi.org/10.1186/1477-7525-6-101
    » https://doi.org/10.1186/1477-7525-6-101
  • [19]
    Bortoluzzi MC, Traebert J, Lasta R, Da Rosa TN, Capella DL, Presta AA. Tooth loss, chewing ability and quality of life. Contemp Clin Dent 2012; 3(4):393-7. https://doi.org/10.4103/0976-237X.107424
    » https://doi.org/10.4103/0976-237X.107424
  • [20]
    Leake JL. An index of chewing ability. J Public Health Dent 1990; 50(4):262-7. https://doi.org/10.1111/j.1752-7325.1990.tb02133.x
    » https://doi.org/10.1111/j.1752-7325.1990.tb02133.x
  • [21]
    Bowers D. Medical Statistics From Scratch: An Introduction for Health Professionals. London: John Wiley & Sons; 2019.
  • [22]
    Everitt BS. Medical Statistics From A to Z: A Guide for Clinicians and Medical Students. Cambridge University Press; 2021.
  • [23]
    Mukaka MJ. Statistics corner: a guide to appropriate use of correlation in medical research. Malawi Med J 2012; 24(3):69-71.
  • [24]
    Goncharuk-Khomyn M, Andrii K. Evaluation of peri-implant bone reduction levels from superimposition perspective: pilot study among Ukrainian implantology practice. Pesqui Bras Odontopediatria Clin Integr 2018; 18(1):3856. https://doi.org/10.4034/PBOCI.2018.181.10
    » https://doi.org/10.4034/PBOCI.2018.181.10
  • [25]
    El Osta N, El Osta L, Moukaddem F, Papazian T, Saad R, Hennequin M, Khabbaz LR. Impact of implant-supported prostheses on nutritional status and oral health perception in edentulous patients. Clin Nutr ESPEN 2017; 18:49-54. https://doi.org/10.1016/j.clnesp.2017.01.001
    » https://doi.org/10.1016/j.clnesp.2017.01.001
  • [26]
    Elsyad MA, Mahanna FF, Elshahat MA, Elshoukouki AH. Locators versus magnetic attachment effect on peri-implant tissue health of immediate loaded two implants retaining a mandibular overdenture: a 1-year randomised trial. J Oral Rehabil 2016; 43(4):297-305. https://doi.org/10.11607/jomi.7484
    » https://doi.org/10.11607/jomi.7484
  • [27]
    Kucukkurt S, Özturk C. Comparison of the effects of two different types of retainers used in implant-supported overdenture prosthesis on patient satisfaction. Yeditepe Dent J 2020; 16(1):74-80. https://doi.org/10.5505/yeditepe.2020.71676
    » https://doi.org/10.5505/yeditepe.2020.71676
  • [28]
    Chaware SH, Thakkar ST. A systematic review and meta-analysis of the attachments used in implant-supported overdentures. J Indian Prosthodont Soc 2020; 20(3):255-268. https://doi.org/10.4103/jips.jips_368_19
    » https://doi.org/10.4103/jips.jips_368_19
  • [29]
    Matthys C, Vervaeke S, Besseler J, Doornewaard R, Dierens M, De Bruyn H. Five years follow-up of mandibular 2-implant overdentures on locator or ball abutments: Implant results, patient-related outcome, and prosthetic aftercare. Clin Implant Dent Relat Res 2019; 21(5):835-44. https://doi.org/10.1111/cid.12840
    » https://doi.org/10.1111/cid.12840
  • [30]
    Brandt S, Lauer HC, Fehrenz M, Güth JF, Romanos G, Winter A. Ball versus Locator® attachments: a retrospective study on prosthetic maintenance and effect on oral-health-related quality of life. Materials 2021; 14(4):1051. https://doi.org/10.3390/ma14041051
    » https://doi.org/10.3390/ma14041051
  • [31]
    Eren Türk P, Geckili O, Türk Y, Günay V, Bilgin T. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures. Int J Oral Maxillofac Implants 2014; 29(5):1106-13. https://doi.org/10.11607/jomi.3621
    » https://doi.org/10.11607/jomi.3621
  • [32]
    Hassan SS, Helmy MH. Implant supported mandibular overdentures with Locator attachments in patients with resorbed mandibular ridges. A cross over study of patient satisfaction and oral health related quality of life. Egypt Dent J 2020; 66:671-81. https://doi.org/10.21608/EDJ.2020.79139
    » https://doi.org/10.21608/EDJ.2020.79139
  • [33]
    Abdelhamid AM, Metwally NA, Imam MH. The effect of two different attachments with implant retained mandibular overdentures on the masticatory function. J Dent Health Oral Disord Ther 2016; 4(2):38-45. https://doi.org/10.15406/jdhodt.2016.04.00101
    » https://doi.org/10.15406/jdhodt.2016.04.00101
  • [34]
    Abdel-Bary SK, Alameldeen HE. Electromyographic evaluation of implant overdenture retained by two different types of attachments (randomized control trial). Egypt Dent J 2019; 65(4):3751-61. https://doi.org/10.21608/EDJ.2019.76021
    » https://doi.org/10.21608/EDJ.2019.76021
  • [35]
    Elsyad MA, Ibrahim AE, Nawar NH, Belal TM. Electromyographic connectivity of masseter muscle with different retentive attachments for implant overdentures in patients with atrophied mandibular ridges: a crossover study. Int J Oral Maxillofac Implants 2019; 34(5):1213-22. https://doi.org/10.11607/jomi.7484
    » https://doi.org/10.11607/jomi.7484
  • [36]
    Sun X, Zhai JJ, Liao J, Teng MH, Tian A, Liang X. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures. Saudi Med J 2014; 35(10):1195-202.
  • [37]
    Awad MA, Rashid F, Feine JS. Overdenture effectiveness study team consortium. The effect of mandibular 2-implant overdentures on oral health-related quality of life: an international multicentre study. Clin Oral Implants Res 2014; 25(1):46-51. https://doi.org/10.1111/clr.12205
    » https://doi.org/10.1111/clr.12205

Edited by

Academic Editor: Alidianne Fábia Cabral Cavalcanti