Acessibilidade / Reportar erro

Behavior predictions of deep beams with short straight bar anchorages using strut-and-tie models and nonlinear analysis

Previsão do comportamento de vigas-parede com comprimentos reduzidos de ancoragem utilizando modelos de escoras e tirantes e análises não-lineares

Abstract

This paper investigates the laboratory test results of 12 deep beams available in the literature, where the longitudinal reinforcement was anchored into the support using short straight bar anchorages. Four different specimen groups with three different shear span-to-depth ratios (a/d) were selected and most of the deep beams failed by strut crushing after yielding of the main longitudinal reinforcement. In order to investigate the behavior of the selected deep beams, an enhanced strut-and-tie model assuming geometrical adaptability (possibility of update in the dimensions of the struts and ties as the main tie starts to yield) is proposed. The analytical results obtained using this approach may be considered as much as accurate than some conducted complex nonlinear analysis considering smeared fixed cracking model and bond-slip behavior. However, an improvement on the effective strength factor of bottle-shaped struts by means of an iterative strut-and-tie model is needed, once the effective strength factor prescribed by NBR6118 (2014) has shown to be over conservative for all ranges of span-to-depth ratio (a/d) investigated. Finally, the obtained results indicated that short bar anchorages did not seem to influence significantly the shear strength of the deep beams investigated, especially the strength of bottled-shaped struts when appropriate crack control reinforcement is present.

Keywords:
deep-beams; strut-and-tie model; nonlinear analysis

Resumo

O presente artigo tem por objetivo investigar os resultados experimentais de 12 vigas-parede em que as armaduras longitudinais foram ancoradas com comprimentos reduzidos de ancoragem junto aos apoios. Quatro grupos de testemunhos com três relações distintas entre o vão e a altura útil (a/d) foram selecionados, observando que a maioria das vigas-parede chegaram à ruína devido ao esmagamento das escoras logo após o escoamento das armaduras longitudinais. De modo a investigar o comportamento das vigas-parede selecionadas, um modelo aperfeiçoado de escoras e tirantes assumindo adaptabilidade geométrica (possibilidade de atualização das dimensões das escoras e dos tirantes conforme a armadura principal começa a escoar) foi desenvolvido. As respostas analíticas obtidas utilizando o procedimento proposto podem ser consideradas tão apuradas quanto respostas numéricas obtidas utilizando análises não-lineares com o modelo de fissuração distribuída acoplado a relações constitutivas para aderência/escorregamento entre concreto e armaduras. No entanto, apesar das respostas analíticas obtidas serem apuradas, observou-se que há necessidade de melhoria no parâmetro que afeta a resistência efetiva de escoras garrafa pela NBR6118 (2014), uma vez que o parâmetro atualmente prescrito pela norma brasileira revelou-se muito conservativo para todas as relações a/d investigadas. Finalmente, os resultados obtidos indicam que os comprimentos reduzidos de ancoragem utilizados aparentemente não influenciaram de maneira significativa a resistência ao cisalhamento das vigas-parede investigadas, especialmente se as escoras garrafas encontravam-se adequadamente controladas por armaduras de controle de fissuração.

Palavras-chave:
vigas-parede; modelos de escoras e tirantes; análise não-linear

1. Introduction

Schlaich et al. [1][1] SCHLAICH, J.; SCHAFER, K.; JENNEWEIN, M.. "Toward a consistent design of reinforced concrete structures". Journal of Prestressed Concrete Structures, v.32, n.3, pp.74-150, 1987. suggested the idea of subdividing a structure into ''B-Regions'' and ''D-Regions'', in order to develop a rational procedure to design reinforced/prestressed concrete structures. On the one hand, ''B-Regions'' are those areas in a structural element where one can follow the ''Bernoulli Hypothesis'', i.e., the hypothesis that linear strains can be assumed through the whole cross section, from the beginning of the loading to the failure of the section. On the other hand, ''D-Regions'' are areas where non-linear deformations occur throughout the cross section and the usual design procedures based on the ''Beam Theory'' become inadequate and even unsafe if applied. In these regions, usually corresponding to sudden changes in geometry or loading, there is a complex stress state mainly generated by shear deformations. As examples of ''D-Regions'' the following parts of a structure may be mentioned: pile caps, footings, deep beams, corbels, dapped end beams, areas around openings or changes in depth, and prestressing reinforcement anchorage zones.

Generally, ''D-Regions'' are produced by concentrated and/or geometric perturbations, and the length of these discontinuity regions may be found using the Saint Venant's Principle, i.e., the zones of dissipation of perturbations are usually defined based on the height of the member. In this way, deep beams may be considered discontinuity regions (''D Regions'') entirely, and the application of the Beam Theory is not adequate.

Based on the fact that the Beam Theory is not appropriate for designing "D Regions", NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. has positively introduced some important guidance and parameters for the appropriate development of strut-and-tie models. Strut-and-tie models are constructed using an assembly of compression (struts) and tension (ties) members connected at joints (nodes) to represent the real stress field in a structural member (or a portion of it) in a simplified manner. The parameters included in NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. mainly pertain to the effective strength to be assumed for concrete struts under different stress levels. The introduction of this minimum guidance follows provisions contained in other structural codes around the world, as for example: ACI318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014., EC2 [4][4] EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004. and FIB MC [5][5] FÉDÉRATION INTERNATIONALE DU BÉTON (FIB). "fib Model Code for Concrete Structures 2010", Lausanne, 402 pp, 2013. .

The effective strength of concrete recommended by the Brazilian code may be considered as the product of an effective factor (ν) by the design compressive strength of the concrete (fcd). Furthermore, the effective factor (ν) may be defined as the product of a variable parameter μ (based on the type of strut or node) and the fragility parameter αv2 (based on the compressive strength of the concrete).

In the Brazilian Code, the parameter μ may assume three different values (0,85; 0,72; and 0,60) depending on the kind of strut or node to be designed. As the level of transverse tensile stress increases in the strut/node the parameter μ decreases. For prismatic struts or nodes where only struts meet (CCC nodes), i.e., elements where the level of transverse tensile stress may be neglected, Brazilian code suggests the following effective strength for design:

For bottle-shaped struts (struts subjected to significant transverse tensile stress) or nodes where more than one tie under different directions meet (CTT nodes), Brazilian code suggests the following effective strength for design:

For nodes where a single tie meets two ore more struts (CCT nodes), the following effective strength for design is suggested by Brazilian code:

The adoption of the brittleness parameter αv2 used to affect the effective strength of concrete was an important decision in the Brazilian code, which allows the recommended parameters be also used for high strength concrete structures. ACI318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014., for example, assumes a constant factor of 0,85 that may be inappropriate for high strength concrete, taking into account the brittleness of this structural material. EC2 [4][4] EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004. presents the same equation proposed by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. while FIB MC [5][5] FÉDÉRATION INTERNATIONALE DU BÉTON (FIB). "fib Model Code for Concrete Structures 2010", Lausanne, 402 pp, 2013. adopts the expression (30/fck)1/3 for the brittleness parameter.

On the other hand, the recommendation of a single parameter (μ) to model bottled-shaped struts seems to be inappropriate, as cracking control requires use of mandatory skin reinforcement which is not considered in the effective concrete strength. FIB MC [5][5] FÉDÉRATION INTERNATIONALE DU BÉTON (FIB). "fib Model Code for Concrete Structures 2010", Lausanne, 402 pp, 2013. also does not take into account secondary reinforcement (skin reinforcement) and for bottle-shaped struts the recommended value for μ is 0,55.

ACI318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014. recommends for struts controlled by a minimum amount of reinforcement (as specified in section A.3.3), a factor βs of 0,75; observe that βs described in the American code corresponds to the parameter μ previously defined in this paper. If the minimum amount of reinforcement is less than specified in section A.3.3, the factor βs should be 0,60; the same factor μ recommend by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. for any amount or lack of skin reinforcement. EC2 [4][4] EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004. defines the discussed parameter μ based on a ratio of 0,4% of transverse tensile reinforcement as well as on the inclination of the strut. If no transverse reinforcement is provided, μ is assumed as 0,60. If 0,4% of transverse tensile reinforcement is available, μ may assume the following values: 0,85 (for θ ³ 75o), 0,70 (for 75o > θ ³ 60 o) and 0,55 (for θ < 60 o).

Based on the mentioned differences above, the present paper aims at investigating the suitability of the effective concrete strength factors recommended by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.. Special attention is given to the evaluation of the effective strength factor of bottle-shaped struts, as this parameter has the largest variation among all the possible parameters. In order to conduct this evaluation, laboratory test results of 12 deep beams in which the longitudinal reinforcement was anchored into the support using short straight bar anchorages were selected. The tests are fully described by Roy & Breña [6][6] ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008. and Breña & Roy [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009..

The obtained results show that behavior predictions of deep beams using the recommendations of NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. may be compared to simulations applying complex nonlinear analysis. However, the effective strength factor to be applied to bottle-shaped struts controlled with crack control reinforcement must be updated, once the actual proposed value seems to be more appropriate for bottle-shaped struts with no reinforcement or skin reinforcement below a minimum ratio.

2. Selected results of deep beams with short anchorages

Twelve simply supported deep beams subjected to a single concentrated load at midspan, having three different shear span to effective depth ratios (a/d) and at least three different anchorage lengths of the main longitudinal reinforcement at the support for each a/d were selected from the researches described by Roy & Breña [6][6] ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008. and Breña & Roy [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009.. The beams were divided into four groups depending on their a/d (1,0; 1,5 or 2,0) and size of main longitudinal reinforcing bars (bar #5 corresponding to a diameter of about 16 mm and bar #6 corresponding to a diameter of about 19 mm).

The span in all beams was equal to 1,22 m and specimens were subjected to a single concentrated force at midspan. Thick steel plates (25 mm) were placed below the loading point and above reaction points to avoid localized crushing at the nodal zones. The beam supports consisted of a pin (test end of beam; straight anchorage) and a roller (far end of beam; hooked anchorage) in all tests. A 445 kN (100 kip) load cell was placed underneath each support to measure reactions throughout the tests and external/internal instrumentation was placed at selected locations in the specimens.

The main variable in each group of beams was the anchorage condition of longitudinal bars over one of the supports. On the test side (left side), the longitudinal reinforcement was continued for different distances past the support node in the various specimens (straight bar anchorage). Longitudinal reinforcement on the far side (right side) of the beams was anchored past the support using a standard 90-degree hook to preclude anchorage failures on that end of the specimens.

Specimen designation was developed to identify the four different groups of beams according to their a/d, longitudinal reinforcing bar size, and straight bar anchorage length on the test end of the beams. The first two digits in the beam designation correspond to the a/d of each beam (1,0; 1,5 or 2,0), and the last three digits correspond to the ratio of provided anchorage length and calculated development length on the test side according to provisions in Chapter 12 of ACI 318-05 [8][8] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2005) and Commentary (ACI 318R-2005), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit , 2005..

Specimen nominal dimensions and reinforcing patterns are shown in Figure [1]. All beams had a nominal width of 152 mm and total depths of 635, 457 or 356 mm for beams with a/d of 1,0; 1,5 or 2,0, respectively. Ten of the 12 specimens had two #5 bars as bottom longitudinal reinforcement (Groups 1.0, 1.5 and 2.0), and the remaining two were reinforced with two No. 6 bars (Group 1.0L). The average yield stress measured for #5 and #6 bars was 492 and 469 MPa, respectively. An average peak stress measured for #5 and #6 bars was 758,5 and 709,5 MPa, respectively. Top reinforcement for all beams consisted of two #3 bars used for constructability of the beam reinforcing cage.

Figure 1
Specimen geometry, reinforcement and experimental test setup for the deep beams tested by BREÑA & ROY (2009)

Longitudinal reinforcement was anchored past the support plate using either a straight bar anchorage or a hooked bar anchorage as shown in Figure [1]. Anchorage length of the longitudinal reinforcement was measured as the distance between the point where the bars leave the extended nodal zone (Fig. RA.1.6 in ACI 318-05 [8][8] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2005) and Commentary (ACI 318R-2005), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit , 2005.), and the end of the bar as required in Section A.4.3.2 of ACI 318-05 [8][8] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2005) and Commentary (ACI 318R-2005), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit , 2005.. The length of the beam extending past the support on the left side varied depending on the provided anchorage length of longitudinal reinforcement. This distance, labeled as O1 in Figure [1], is listed in Table [1] for all specimens.

Table 1
Specimen geometry and reinforcement of the deep beams

Web reinforcement conformed with requirements in section A.3.3 of ACI 318-05 [08] and consisted of vertical stirrups and horizontal bars formed using deformed D4 wire (this bar corresponds to a diameter of about 5,7 mm) with an average measured yield stress equal to 605 MPa and average measured peak stress equal to 643,2 MPa. Horizontal secondary reinforcement corresponded to a reinforcement ratio of about 0,16% for group 1.0 and 1.0L, 0,15% for group 1.5 and 0,09% for group 2.0. By another hand, vertical secondary reinforcement corresponded to a reinforcement ratio of 0,37% for groups 1.0 and 1.0L and 0,25% for groups 1.5 and 2.0.

Just before testing each beam, specimen dimensions were verified and companion concrete cylinders were tested to determine the as-built geometry of the beams and the actual strength of concrete. Due to formwork flexibility, the actual width of the beams varied slightly from the nominal value of 15,2 cm. The measured concrete compressive/tensile strength along with the as-built width of each specimen at the time of testing is listed in Table [1]. This table also shows reinforcement configuration, provided anchorage length on the test side of the beams, yielding/peak loads and failure modes observed in the tests.

3. Evaluation of the effective strength factor of bottle-shaped struts

As mentioned before, NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. does not make a distinction in the effective strength of bottle-shaped struts that contain or lack minimum skin reinforcement. Therefore, the effective strength proposed (fcd2) for this kind of strut may be underestimated when adequate skin reinforcement is provided. Based on this fact, the present section aims to evaluate the accuracy of the effective strength factor for bottle-shaped struts proposed by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. taking into account the experimental results obtained by Roy & Breña [6][6] ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008. and Breña & Roy [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009..

A tied-arch strut and tie model consistent with the peak measured loads and based on the procedure proposed by Wight & Parra-Montesinos [9][9] WIGHT, J. K.; PARRA-MONTESINOS, G.. "Strut and Tie Model for Deep Beam Design," Concrete International, v. 25, n. 5, May, pp. 63-70, 2003., was slightly modified in order to estimate the effective strength of the bottle-shaped struts using the parameters recommend in NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.. In this model, the strut inclination angle and width are determined iteratively. The geometry of the tied-arch model was established so that node strength was observed in the nodal region of the beam, as shown in Figure [2]. For compatibility between code and experimental results, fck is assumed equal to fcm, since the partial safety factor (γc) is assumed equal to 1,0.

Figure 2
Suggested strut-and-tie model for strength evaluation (BREÑA & ROY (2009))

From symmetry of the test setup, the total applied force on the beams resulted in equal shear force transferred to each support. The force in the direct strut forming between load and support in the tied-arch model is FS = V/sinα, where α is the angle of inclination of the strut with the tie. The angle α depends on the horizontal distance between the resultant of one-half of the applied force and the support (56 cm) and the vertical distance between the top and bottom chords in the model (z), Figure [2].

The top-node height hnode-top was initially assumed equal to 5,0 cm to initiate iterations. After determining FS (force acting in the diagonal strut) for the initial α, the top horizontal compressive force (FC) was calculated as FC = FS.cosα. This force (Equation [4][4] EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004.) was then equated to the nominal strength of the top node (Fnn) required to solve for the top-node height (Equation [5][5] FÉDÉRATION INTERNATIONALE DU BÉTON (FIB). "fib Model Code for Concrete Structures 2010", Lausanne, 402 pp, 2013. ) to avoid node crushing:

The depth from top to bottom chords in the model, z, was then revised and a new strut angle α was determined to avoid nodal failure:

Iterations were conducted until hnode-top was approximately the same in three subsequent calculation cycles. In all iterations, the height of the bottom node was assumed equal to 102 mm, twice the distance between the bottom face of the beams and the centroid of the bottom longitudinal reinforcement. Once convergence was achieved and an appropriate strut inclination was found, the top and bottom widths of the diagonal strut were determined using Equation [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009., based on ACI 318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014.:

where the plate widths and node heights used for the top and bottom nodes in the previous equation corresponded to those shown in Figure [2]. Because the bottom plate is wider than half the top plate, the top end of the diagonal strut ended up governing strut strength in all the specimens. This is consistent with the location of observed concrete spalling near the top of the struts in all specimens that failed by strut crushing (Roy & Breña [6][6] ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008., Breña & Roy [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009.). The stress at the top end of the diagonal strut was then calculated using Equation [8][8] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2005) and Commentary (ACI 318R-2005), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit , 2005.:

where the as-built width of the specimens, b, was used and ws-top is the width of the strut determined before at the top node.

Table 2 presents the effective strength of the diagonal bottle-shaped struts according to NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. and also based on the test results. As one can see, the effective strength (fcd2 = 0,60.αv2.fcd) recommended by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. is significantly lower than the average effective strength derived from the experimental results (fce = μ.αv2.fcd = 0,82.αv2.fcd). The effective strength of the tested bottle-shaped struts has an average value 35% higher than the effective strength proposed by NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014..

Table 2
Bottle-shaped strut strength evaluation according to NBR6118 (2014)

The obtained results indicate that the parameter μ = 0,60 assumed by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. for bottled-shaped struts, underestimates the strength of diagonal struts that contain crack control reinforcement, being more appropriate for situations where bottle-shaped struts are not controlled by minimum skin reinforcement specified in ACI 318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014.. In this way, Brazilian code could introduce an additional value for fcd2 (0,80.αv2.fcd, for example), intended for situations where bottle-shaped struts are controlled by minimum crack control reinforcement. Ratios of 0,15%, for vertical and horizontal directions, seems to be appropriate, taking into account the obtained results and additional information provided in ACI 318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014. and EC2 [4][4] EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004..

4. Strut-and-tie model to predict yielding and failure loads

In order to extend the investigation of the experimental results, the simple strut-and-tie model presented in Figure 2.a] is again required. Using the procedures recommend by NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. it is possible to obtain the analytical yielding and failure loads of the tested deep beams. However, improved procedures based on a better estimation of the effective strength of bottle-shaped struts are needed as discussed below.

The strut-and-tie model presented in Figure 2.a] is slightly modified in order to permit defining variable dimensions for the struts and nodal regions. In this reformulated model, the major challenge is the determination of the height of the top horizontal strut (hnode,top). Once this value is known all the other parameters may be easily found using geometry and equilibrium conditions. Assuming that the force in the top strut (FC) must be equal to the maximum force in the main tie (FT), it is possible to determine the height (hnode,top) of the top node and the shear force (V) that generates yielding of the main tie.

Once hnode,top is determined, it is possible to verify strength in all components of the model (nodes, struts, etc.) using the effective strengths recommended by NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.. In this way, estimates of the maximum loads in each component can be obtained by determining the maximum nominal forces acting at the boundaries of the following: top horizontal strut ("prismatic strut"), diagonal strut ("bottle-shaped strut"), bottom node ("CCT node") and top node ("CCC node").

It must be highlighted that the maximum loads obtained for the diagonal and horizontal struts as well as some nodes may be not realistic in some situations, especially if they are dependent on hnode-top. For simplicity, hnode,top is now determined based on the nominal yield force acting in the main tie. However, for a real situation, the value of hnode,top can be larger if needed based on development of higher forces in the main reinforcement because of strain hardening; this increased height can only be developed if enough space is available in the deep beam.

Assuming a bilinear behavior for the reinforcement, after the main tie yields, the height of the top node (hnode-top) may increase to satisfy equilibrium with the main tie if bars are stressed to their peak stress. In this way, it is of interest to calculate the maximum boundary forces when the main tie is subjected to the rupture force. This procedure gives rise to an enhanced strut-and-tie model and provides more realistic failure loads for struts and nodes whose dimensions are dependent on hnode-top. Using the maximum stress of the reinforcement to determine tie forces is valid as long as the material has sufficient deformation capacity beyond its peak stress to avoid brittle failure that would violate a basic principle in the theory of plasticity upon which strut and tie models are based. It must also be highlighted that components of the strut and tie model that are not dependent on hnode-top (maximum reaction in the load bearing plates and maximum force in the main tie, for example), may end up governing the strength of the model if they reach the limiting stress at a lower load than one obtained for components that are affected by hnode,top.

Table [3] summarizes the maximum analytical loads using the proposed strut and tie-model, taking into account that the height of the top horizontal strut (hnode,top) is determined based on yielding (lower bound value for hnode,top) or maximum force in the main tie (upper bound value for hnode,top). For convenience, again fck was assumed as fcm and the partial safety factor (γc) was assumed as equal 1,0.

As one can see, if the parameter μ = 0,60 is used for the bottle-shaped strut, the average failure load calculated using the proposed methodology and NBR6118 [2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. will be conservative and will present an average value of 0,77 between the predicted failure loads and the experimental failure loads (please refer to column (6) of Table [3]). On the other hand, if a higher value μ = 0,80 is selected (based on the results discussed in the previous section), the failure predictions will also be conservative, but now with an average value of 0,81 between the predicted failure loads and the experimental failure loads (please refer to column (8) of Table [3]). The yield load of the specimens is independent of the parameter μ, and the proposed model resulted in a conservative prediction of yield force as an average ratio of 0,89 between the predicted yielding loads and the experimental yielding loads indicates.

Table 3
Comparison between experimental results and the proposed strut-and-tie model

As an example, Appendix A presents the detailed calculations for specimen DB1.0-1.00 using the proposed strut-and tie model, observing that the proposed routine was programmed in the package software MATLAB in order to provide fast responses for the tested specimens.

5. Nonlinear analysis

The deep beams tested by Roy & Breña [6][6] ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008. and Breña & Roy [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009. were also studied using nonlinear finite element analysis using the software package ATENA2D. Several models and solvers were tested and the best results were obtained using the model SBETA for concrete that uses a fixed crack assumption. The default parameters defined in the software were assumed, in order to check the real performance of the software without calibration of the large list of parameters available in the tool. More information regarding the software selected may be found in Cervenka [10,11].

Tested deep beams were modeled using macroelements discretized by CCIsoQuad type elements. Vertical point load was applied at the top of the deep beam and pinned supports were defined at the bottom in order to simulate the experimental setup. Vertical loading and support conditions were applied in the support steel plates that have a Young's modulus of 210 GPa and Poisson's ratio of 0,3.

Reinforcement properties were defined based on the experimental results using a bilinear model. In most practical cases, bond is not a significant effect because the bond strength is only seldom reached. However, in the present investigation, reduced anchorage length was used and bond strength was supposed to affect the final strength of the specimens. For this reason, adherence based on the bond model of Bigaj [12][12] BIGAJ, A.. "Structural Dependence of Rotation Capacity of Plastic Hinges in RC Beams and Slabs". Phd, Delft University of Technology, 1999. was defined only for the main tie (bars # 5 and #6) while the other reinforcement in the beams was defined assuming perfect adherence.

The basic property of the reinforcement bond model is the bond-slip relationship and it defines the bond strength depending on the value of current slip between reinforcement and surrounding concrete. The slip law for the model proposed by Bigaj [12][12] BIGAJ, A.. "Structural Dependence of Rotation Capacity of Plastic Hinges in RC Beams and Slabs". Phd, Delft University of Technology, 1999. depends on the bond quality (poor, good, very good), the concrete compressive strength and reinforcing bar radius. The present bond model in ATENA2D is not directly dependent on confinement caused by normal stresses acting on planes parallel with the reinforcement direction. To account indirectly for the benefit of normal stresses perpendicular to the potential splitting plane, all situations were considered to have a good bond quality.

Loading was applied under displacement control by prescribing vertical displacement at the middle point on top of the loading plate in constant increments of 0,1 mm. The Newton-Raphson solution method was selected and the overall response was recorded at two monitoring points: force at the top loading point and deflection at the bottom of the beam on the symmetry plane.

Table [4] shows the obtained results using ATENA2D considering the following situations: deeps beams with skin reinforcement (results without parenthesis in the table) and without skin reinforcement (results with parenthesis in the table). Deep-beams with skin reinforcement presented higher numerical failure loads when compared to the hypothetical situation of deep-beams without skin reinforcement. In average, the contribution of the skin reinforcement was about 20% in the failure load, revealing the importance of this kind of reinforcement in the strength of bottle-shaped struts.

Table 4
Comparison between experimental results and numerical results using ATENA2D

As one can see, the software presented good results concerning the cracking loads and failure loads. In contrast, the results obtained for yielding loads were not satisfactory. In the experimental research, yielding was not observed only in specimen DB1.0-0.28L. In the numerical analysis, just specimens DB1.0-1.00 and DB1.0-0.75 reached yielding. Despite the fact that yield loads could not be well predicted, the obtained failure modes for the specimens were very similar to the experimental behavior. The slippage of the reinforcement obtained experimentally for some specimens was well detected numerically for the same specimens.

As an example, Figure [3] shows comparisons between the experimental cracking pattern and the obtained numerical cracking pattern for beam DB1.0-0.75. It is possible to observe that shear cracks were precisely predicted, but crushing observed in the experimental tests was not identified in the numerical analysis.

Figure 3
Experimental failure and predicted numerical failure for specimen DB1.0-0.75 (figure only shows crack widths over 0,5 mm)

The obtained results demonstrate the difficulty encountered in accurately capturing the behavior of structures controlled by shear and the importance of verifying results with simple hand equations to help with utilization of complex package software like ATENA2D.

6. Conclusions

NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. recently introduced some guidance and important parameters for designing complex structures using strut-and-tie models. As these new information are now available, some discussions regarding the recommended effective strength for concrete in struts and nodes will become more frequent.

In this way, the present paper has used a simple strut-and-tie model in order to check the accuracy of the effective strength recommended by NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. for bottle-shaped struts. Based on the available experimental results of 12 deep beams tested by Roy & Breña [6][6] ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008. and Breña & Roy [7][7] BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009., it has been possible to show that the effective strength factor recommend by the Brazilian code is quite conservative, especially for situations where secondary reinforcement are available.

As mentioned throughout the paper, NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. unfortunately does not make a distinction whether or not a bottle-shaped strut is controlled by secondary (skin) reinforcement. Structural codes like ACI 318-14 [3][3] ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014. and EC2[4][4] EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004., for example, have realized the importance of secondary reinforcement in the effective strength of bottle-shaped struts and for that reason a higher effective strength factor is allowed for bottle-shaped struts.

The effective strength recommended by NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014. for bottle-shaped struts is given by fcd2 = μ.αv2.fcd = 0,60.αv2.fcd. Based on the experimental results, the applied strut-and-tie model has shown that for bottle-shaped struts controlled by skin reinforcement (horizontal and vertical mesh) higher than 0,10%, the strength factor μ would be about 0,80.

Despite the fact that more data are needed in order to certify the findings of this paper, it is recommended the inclusion of a more appropriate effective strength for bottle-shaped struts controlled by cracking control reinforcement in NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.. As the secondary reinforcement is mandatory in wall-type structures, the effective strength of bottle-shaped struts should be more flexible.

The enhanced strut-and-tie model proposed in this paper has shown to be as powerful as nonlinear analysis using bond models with the package software ATENA2D. Despite the fact that nonlinear analysis was very effective to predict the global behavior of the beams, accurately predicting the cracking pattern and positions of slippage of the reinforcement, the obtained results regarding yielding of the reinforcement were not accurate.

It should be highlighted that the proposed strut-and-tie model has a small enhancement when compared to the usual strut-and-tie models developed for predicting behavior of deep beams. The proposed strut-and-tie model takes into account the effect of strain hardening of the reinforcement on governing dimensions of struts and ties in the selected model. Unless the main reinforcement suffers rupture at low strains, a force higher than the yielding force is still possible.

After yielding, a new arrangement for the dimensions of struts and nodes is possible in the proposed model, simulating in that way the stress redistribution of the structure. The limit for the dimensions of struts and nodes is based on the rupture force of the main tie and a more accurate procedure may be obtained for predicting the peak load after the yielding of the main tie. The classical approach used in the strut-and-tie assumes that when yielding is reached, failure is obtained, and for that reason over conservative results are usually obtained.

Basically, the height of the upper horizontal strut is defined based on the force acting in the main tie, i.e., the force supposed to cause yielding or rupture of the reinforcement. By consequence, all other necessary dimensions can be automatically calculated. With this assumption in hand it is possible to check whether or not the structure will fail by the reinforcement or by the struts or nodes. This very simple procedure has been programmed in MATLAB and conducted to very good accuracy predicting yielding and failure loads of the tested specimens.

Finally, the present paper reveals that short bar anchorages did not seem to influence significantly the strength of the deep beams tested experimentally, especially the strength of bottle-shaped struts. Also, the present paper shows that hand calculations based on strut-and-tie models can be very effective with some adaptations, providing fast results and invaluable guidance for applying nonlinear analysis with confidence.

7. Acknowledgements

The authors would like to acknowledge the Brazilian government agency CNPq for the financial support and the University of Massachusetts Amherst by the support during the Post-Doctoral stage of the first author. The authors also would like to acknowledge Nathan C. Roy who performed the experimental work described within this paper as part of his Masters thesis at the University of Massachusetts Amherst during 2006. The conclusions and opinions expressed in this paper are the authors' responsibility and do not reflect the points of view of the sponsors.

8. References

  • [1]
    SCHLAICH, J.; SCHAFER, K.; JENNEWEIN, M.. "Toward a consistent design of reinforced concrete structures". Journal of Prestressed Concrete Structures, v.32, n.3, pp.74-150, 1987.
  • [2]
    ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.
  • [3]
    ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2014) and Commentary (ACI 318R-2014), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit, 2014.
  • [4]
    EUROPEAN COMMITTEE STANDARDIZATION. "Eurocode 2 - Design of concrete structures - Part 1-1: General rules and rules for buildings". London: BSI; 230p, 2004.
  • [5]
    FÉDÉRATION INTERNATIONALE DU BÉTON (FIB). "fib Model Code for Concrete Structures 2010", Lausanne, 402 pp, 2013.
  • [6]
    ROY, N. C.; BREÑA, S. F.. "Behavior of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.105, n.104, 2008.
  • [7]
    BREÑA, S. F.; ROY, N. C.. "Evaluation of Load Transfer and Strut Strength of Deep Beams with Short Longitudinal Bar Anchorages", ACI Structural Journal, v.106, n.05, 2009.
  • [8]
    ACI COMMITTEE 318, "Building Code Requirements for Structural Concrete (ACI 318-2005) and Commentary (ACI 318R-2005), APPENDIX A: Strut-And-Tie Models". American Concrete Institute, Detroit , 2005.
  • [9]
    WIGHT, J. K.; PARRA-MONTESINOS, G.. "Strut and Tie Model for Deep Beam Design," Concrete International, v. 25, n. 5, May, pp. 63-70, 2003.
  • [10]
    CERVENKA, V. & CERVENKA, J.. "ATENA Program Documentation - Part 2-1: User's Manual for ATENA2D", Prague, 2003.
  • [11]
    CERVENKA, V. & CERVENKA, J.. "ATENA Program Documentation - Part 2-2: User's Manual for ATENA3D", Prague, 2005.
  • [12]
    BIGAJ, A.. "Structural Dependence of Rotation Capacity of Plastic Hinges in RC Beams and Slabs". Phd, Delft University of Technology, 1999.

9. APPENDIX A

A.1) Initial data for deep beam DB1-1.00:

As = 4,0 cm2 (longitudinal steel area of the main tie)

fy = 492 MPa (yielding strength of the main reinforcement)

fu = 758,5 MPa (ultimate strength of the main reinforcement)

b = 16,5 cm (width of the deep beam)

d = 58,1 cm (effective depth of the deep beam)

fcm = 33,3 MPa (compressive strength of the concrete)

hnode-bott = 2.(h-d) = 2.5,40 = 10,80 cm (estimated width of the main tie)

Lplate,bott = 11,4 cm (length of the support plate used in the top)

Lplate,top = 20,3 cm (length of the support plate used in the bottom)

Lbeam = 122 cm (spam of the deep beam between supports)

A.2) Yielding of the main tie (assuming f ck = f cm and γ c = 1,0):

FT = As.fy = 4.49,2 = 196,80 kN

FT = FC = 196,80 kN

αv2 = (1 - fck/250) = (1 - 33,3/250) = 0,87

Fns = fcd1.Acs = 0,85.αv2.fcd.b.htop,min = FC

hnode-top = FC /(0,85.αv2.fcd.b) = 196,80 / (0,85.0,87.3,33.16,5) = 4,84 cm (minimum height needed)

z = d - hnode-top/2 = 58,1 - 4,84/2 = 55,68 cm

a = (Lbeam/2) - (Lplate,top /4) = (122/2) - (20,3/4) = 55,93 cm

α = arc tg (z/a) = arc tg (55,68/55,93) = 44,87o

FT = FS.cosα ? FS = FT/cosα = 196,80/cos 44,87o = 277,68 kN

FS = Q/sinα ? Q = FS.sinα = 277,68.sin 44,87o = 195,90 kN

Q1y = P1y/2 ? P1y = Q1y.2 = 195,63.2 = 391,80 kN (Yielding load for the main reinforcement)

A.3) Failure of the CCT bottom node (μ = 0,72 according to NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.):

Failure due to the reaction force ?

Q2y,a = fcd3.Anz = 0,72.αv2.fcd.b.Lplate,bott = 0,72.0,87.3,33.16,5.11,4 = 392,36 kN

P2y,a = 2.Q2y,a = 784,72 kN

Failure due to the tie force ?

Q2y,b = fcd3.Anz = 0,72.αv2.fcd.b.hnode,bott = 0,72.0,87.3,33.16,5.10,80 = 371,70 kN

P2y,b = 2.Q2y,b = 743,40 kN

Failure due to the diagonal force ?

ws,bott = Lplate-bott.sinα + hnode-bott.cosα = 11,4.sin 44,87o + 10,80.cos 44,87o = 15,69 cm

P2y,c = fcd3.Anz = 0,72.αv2.fcd.b.ws,bott = 0,72.0,87.3,33.16,5.15,69 = 540,01 kN

P2y,c = 2.Q2,c = 1080,02 kN

A.4) Failure of the CCC top node (μ = 0,85 according to NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.):

Failure due to the reaction force ?

Q3y,a = fcd1.Anz = 0,85.αv2.fcd.b.(0,5.Lplate,top) = 0,85.0,87.3,33.16,5.10,15 = 412,41 kN

P3y,a = 2.Q3y,a = 824,82 kN

Failure due to the horizontal force in the strut ?

Q3y,b = fcd1.Anz = 0,85.αv2.fcd.b.hnode-top = 0,85.0,87.3,33.16,5.4,84 = 196,65 kN

P3y,b = 2.Q3y,b = 393,30 kN (Observe that this value depends on minimum hnode,top and may be neglected)

Failure due to the diagonal force ?

ws,top = 0,5.Lplate-top.sinα + hnode-top.cosα = 10,15.sin 44,87o + 4,84.cos 44,87o = 10,59 cm

Q3y,c = fcd1.Anz = 0,85.αv2.fcd.b.ws,top = 0,85.0,87.3,33.16,5.10,59 = 430,29 kN

P3y,c = 2.Q3y,c = 860,58 kN (Observe that this value depends on minimum hnode,top and may be neglected)

A.5) Failure of the diagonal bottle-shaped strut (μ = 0,60 according to NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.):

FS = fcd2.Ans = 0,60.αv2.fcd.b.ws = 0,60.0,87.3,33.16,5.10,59 = 303,73 kN

Q4,y = FS.sinα = 303,73.sin 44,87o = 214,28 kN

P4,y = 2.Q4,y = 428,56 kN (Observe that this value depends on minimum hnode,top and may be neglected)

A.6) Failure of the horizontal top strut (μ = 0,85 according to NBR6118[2][2] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. "NBR 6118 - Projeto de Estruturas de Concreto - Procedimento", Rio de Janeiro, 2014.)

FC = fcd1.Ans = 0,60.αv2.fcd.b.hnode,top = 0,85.0,87.3,33.16,5.4,84 = 196,65 kN

Q5,y = FC.sinα/cos α = 196,65.sin 44,83o/cos 44,83o = 195,48 kN

P5,y = 2.Q5,y = 390,96 kN (Observe that this value depends on minimum hnode,top and may be neglected)

A.7) Selection of the prediction loads

Repeating the previous calculations considering the rupture of the main reinforcement, Table [A.1] may be constructed and load values may be organized in crescent order to determine the interest loads. Based on this crescent sequence is possible to realize that deep beam DB1-1.00 will yield for P = 391,80 kN and will fail for P =471,76 kN (due to the failure of the diagonal strut).

Table A.1
Predicted loads for deep beam DB1-1.00 using the proposed strut and tie model

Publication Dates

  • Publication in this collection
    Oct 2016

History

  • Received
    10 Aug 2015
  • Accepted
    09 Mar 2016
IBRACON - Instituto Brasileiro do Concreto Instituto Brasileiro do Concreto (IBRACON), Av. Queiroz Filho, nº 1700 sala 407/408 Torre D, Villa Lobos Office Park, CEP 05319-000, São Paulo, SP - Brasil, Tel. (55 11) 3735-0202, Fax: (55 11) 3733-2190 - São Paulo - SP - Brazil
E-mail: arlene@ibracon.org.br