Acessibilidade / Reportar erro

Effect of different bonding protocols on degree of monomer conversion and bond strength between orthodontic brackets and enamel

Abstract

The objective of the present study was to evaluate the effect of different surface treatments and polymerization protocols on the bond strength of brackets to enamel, and the degree of conversion of the bonding agents. 120 bovine crowns were embedded in acrylic resin blocks and sanded. Next, the blocks were randomly assigned into 12 groups. Metal brackets were bonded to enamel according to the “surface treatment” factor (A: Phosphoric Acid; ATxt: Phosphoric Acid + Transbond XT Primer®; Tse: Transbond Plus Self Etching Primer®; and SBU: Scotchbond Universal®) and “polymerization” factor (R20: Radii-Cal®/20 seconds; V20: Valo Cordless®/20 seconds; and V3: Valo Cordless®/3 seconds). All samples were stored for 6 months (water, 37ºC) and then subjected to a shear bond strength test (SBS). Bond failures were classified according to the Adhesive Remnant Index (ARI) and analyzed with the Kruskal-Wallis and Mann-Whitney tests (5%). Using the same factors, 120 resin discs were made to assess the degree of conversion (DC) of the monomer. Data from the SBS (MPa) and DC (%) were analyzed by analysis of variance (2 factors) and Tukey’s test (5%). For the SBS, the factors “polymerization” (R20 = 8.1B; V20 = 13.2A; V3 = 5.2C, p = 0.0001) and “surface treatment” (A = 3.1C; ATxt = 13.6A; Tse = 12.3A; SBU = 6.3B, p = 0.0001) were statistically significant among groups. The highest adhesion value were found for the ATxt/V20 group (22.2A) and the lowest value for the A/R20 group (1.2E). Regarding ARI, score 2 was the most prevalent in groups A, ATxt, V20 and V3, while score 4 was the most prevalent in the Tse, SBU and R20 groups, with no significant difference between them (p = 1.0). Regarding DC, the factors “polymerization” (R20 = 66.6A; V20 = 58.4B; V3 = 45.1C, p = 0.0001) and “surface treatment” (A = 52B, ATxt = 59.7A, Tse = 51.4B, SBU = 63.8A, p = 0.0001) were statistically significant. Tse was more sensitive to the variations in polymerization protocols than the other surface treatments. Treatment A did not present suitable bond strength or degree of conversion.

Adhesiveness; Dental Enamel; Orthodontic Brackets

Introduction

Orthodontics has evolved considerably in recent decades improving aspects such as treatment planning and diagnosis11. Wang CH, Randazzo L. Evolution of imaging and management systems in orthodontics. Am J Orthod Dentofacial Orthop. 2016 Jun;149(6):798-805. https://doi.org/10.1016/j.ajodo.2016.03.016
https://doi.org/10.1016/j.ajodo.2016.03....
, clinical performance22. Takaki T, Tamura N, Yamamoto M, Takano N, Shibahara T, Yasumura T et al. Clinical study of temporary anchorage devices for orthodontic treatment: stability of micro/mini-screws and mini-plates: experience with 455 cases. Bull Tokyo Dent Coll. 2010;51(3):151-63. https://doi.org/10.2209/tdcpublication.51.151
https://doi.org/10.2209/tdcpublication.5...
and patient comfort.33. Goswami A, Mitali B, Roy B. Shear bond strength comparison of moisture-insensitive primer and self-etching primer. J Orthod Sci. 2014 Jul;3(3):89-93. https://doi.org/10.4103/2278-0203.137695
https://doi.org/10.4103/2278-0203.137695...
,44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
Factors that can influence clinical performance include bracket design and type55. Songra G, Clover M, Atack NE, Ewings P, Sherriff M, Sandy JR et al. Comparative assessment of alignment efficiency and space closure of active and passive self-ligating vs conventional appliances in adolescents: a single-center randomized controlled trial. Am J Orthod Dentofacial Orthop. 2014 May;145(5):569-78. https://doi.org/10.1016/j.ajodo.2013.12.024
https://doi.org/10.1016/j.ajodo.2013.12....
, composition of the orthodontic wire66. Bellini H, Moyano J, Gil J, Puigdollers A. Comparison of the superelasticity of different nickel-titanium orthodontic archwires and the loss of their properties by heat treatment. J Mater Sci Mater Med. 2016 Oct;27(10):158. https://doi.org/10.1007/s10856-016-5767-5
https://doi.org/10.1007/s10856-016-5767-...
, and, especially, the resins and adhesive systems used for bracket bonding.77. Dominguez GC, Tortamano A, Lopes LV, Catharino PC, Morea C. A comparative clinical study of the failure rate of orthodontic brackets bonded with two adhesive systems: conventional and self-etching primer (SEP). Dental Press J Orthod. 2013 Mar-Apr;18(2):55-60. https://doi.org/10.1590/S2176-94512013000200014
https://doi.org/10.1590/S2176-9451201300...
,88. Mohammed RE, Abass S, Abubakr NH, Mohammed ZM. Comparing orthodontic bond failures of light-cured composite resin with chemical-cured composite resin: A 12-month clinical trial. Am J Orthod Dentofacial Orthop. 2016 Aug;150(2):290-4. https://doi.org/10.1016/j.ajodo.2016.02.013
https://doi.org/10.1016/j.ajodo.2016.02....
Adhesion failures between bracket and tooth surface compromise the success of the orthodontic treatment, are costly, and cause inconvenience to the patient.33. Goswami A, Mitali B, Roy B. Shear bond strength comparison of moisture-insensitive primer and self-etching primer. J Orthod Sci. 2014 Jul;3(3):89-93. https://doi.org/10.4103/2278-0203.137695
https://doi.org/10.4103/2278-0203.137695...

Bonding brackets to dental enamel is a routine procedure in Orthodontics and it usually follows the protocol proposed by Buonocore99. Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res. 1955 Dec;34(6):849-53. https://doi.org/10.1177/00220345550340060801
https://doi.org/10.1177/0022034555034006...
in which the enamel surface is conditioned with 37% phosphoric acid to increase adhesiveness. Although prior acid conditioning (conventional system) is still the most employed method, the use of self-etching (single step) adhesive systems has recently gain some interest.1010. Grünheid T, Larson BE. Grünheid T, Larson BE. Repeated bracket bonding: conventional or self-etching primer? J World Fed Orthod. 2014;3(3):102-5. https://doi.org/10.1016/j.ejwf.2014.05.001
https://doi.org/10.1016/j.ejwf.2014.05.0...
In addition to simplifying the procedure with consequent reduction of clinical time and greater standardization, self-conditioning systems have greater tolerance to moisture33. Goswami A, Mitali B, Roy B. Shear bond strength comparison of moisture-insensitive primer and self-etching primer. J Orthod Sci. 2014 Jul;3(3):89-93. https://doi.org/10.4103/2278-0203.137695
https://doi.org/10.4103/2278-0203.137695...
and possible antimicrobial properties due to the presence of adhesive monomers in their composition.1111. Esteves CM, Ota-Tsuzuki C, Reis AF, Rodrigues JA. Antibacterial activity of various self-etching adhesive systems against oral streptococci. Oper Dent. 2010 Jul-Aug;35(4):448-53. https://doi.org/10.2341/09-297-L
https://doi.org/10.2341/09-297-L...

To be clinically effective, self-conditioning systems must promote a satisfactory bond strength between brackets and enamel. Some authors1212. Yadala C, Gaddam R, Arya S, Baburamreddy KV, Raju VR, Varma PK. Comparison of Shear Bond Strength of Three Self-etching Adhesives: An In-Vitro Study. J Int Oral Health. 2015 Jul;7(7):53-7. have found that self-etching systems can have acceptable clinical performance in the bonding of orthodontic brackets compared to the conventional system. On the other hand, recent studies have proposed the bonding of metallic brackets to enamel without the use of adhesives,1313. Bazargani F, Magnuson A, Löthgren H, Kowalczyk A. Orthodontic bonding with and without primer: a randomized controlled trial. Eur J Orthod. 2016 Oct;38(5):503-7. https://doi.org/10.1093/ejo/cjv075
https://doi.org/10.1093/ejo/cjv075...
,1414. Altmann AS, Degrazia FW, Celeste RK, Leitune VC, Samuel SM, Collares FM. Orthodontic bracket bonding without previous adhesive priming: A meta-regression analysis. Angle Orthod. 2016 May;86(3):391-8. https://doi.org/10.2319/041615-255.1
https://doi.org/10.2319/041615-255.1...
since a consensus seems to exist in the literature that a minimum adhesion force (6 to 8 MPa) is sufficient in certain cases,1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...
and that very a high adhesive strength may increase the risk of enamel fracture and pulp damage during bracket removal.1616. Lowder PD, Foley T, Banting DW. Bond strength of 4 orthodontic adhesives used with a caries-protective resin sealant. Am J Orthod Dentofacial Orthop. 2008 Aug;134(2):291-5. https://doi.org/10.1016/j.ajodo.2008.03.002
https://doi.org/10.1016/j.ajodo.2008.03....

Another factor that can influence adhesive resistance is the polymerization protocol.1717. Pinto CM, Ferreira JT, Matsumoto MA, Borsatto MC, Silva RA, Romano FL. Evaluation of different LED light-curing devices for bonding metallic orthodontic brackets. Braz Dent J. 2011;22(3):249-53. https://doi.org/10.1590/S0103-64402011000300012
https://doi.org/10.1590/S0103-6440201100...
A multitude of light-curing devices is currently available, with varying light intensities and polymerization times.1818. McCusker N, Lee SM, Robinson S, Patel N, Sandy JR, Ireland AJ. Light curing in orthodontics; should we be concerned? Dent Mater. 2013 Jun;29(6):e85-90. https://doi.org/10.1016/j.dental.2013.03.023
https://doi.org/10.1016/j.dental.2013.03...
For example, the Valo Cordless®/Ultradent is supplied with a LED-type unit that includes an xtra power mode of 3200 mW/cm2 intensity. Because of these high-intensity light waves, some authors44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
,1919. Ward JD, Wolf BJ, Leite LP, Zhou J. Clinical effect of reducing curing times with high-intensity LED lights. Angle Orthod. 2015 Nov;85(6):1064-9. https://doi.org/10.2319/080714-556.1
https://doi.org/10.2319/080714-556.1...
have suggested a 3- to 6-second polymerization for bracket bonding. Conventional polymerization units emit light intensities from 1000 to 1250 mW/cm2 and are suitable for the bracket bonding with a time of 20 seconds per application.44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....

Based on the scientific literature, there is a wide diversity of protocols and clinical procedures for bonding orthodontic brackets, which makes it difficult for the clinician to make an informed decision. In addition, studies that compare different enamel surface treatments for metallic bracket bonding are lacking, and mostly performed using high intensity light curing units for short polymerization periods.

Therefore, the objective of this work was to evaluate the effect of different surface treatments and polymerization protocols on the bond strength between metallic brackets and enamel, and the degree of conversion of the bonding agents.

The hypotheses tested were: the adhesive strength of metallic brackets bonded to enamel and the degree of conversion of the bonding agents are influenced by the surface treatment and the polymerization protocol.

Methods

Materials

A description of the bonding materials of this study is shown in Table 1.

Table 1
Bonding materials used in this study.

Shear Bond Strength

One hundred and twenty bovine lower incisors with intact crowns were selected. The soft tissue adhered to the roots was removed with periodontal curettes. The roots were separated from the crowns using a double–sided diamond disk mounted on a micromotor and straight handpiece and discarded. The crowns were then stored in distilled water at 4°C until the specimens were prepared (ISO 11405).2020. .International Organization for Standardization. ISO/TS 11405.:2003. Dentistry: testing of adhesion to tooth structure. Geneva: International Organization for Standardization; 2003. The crowns were embedded in colorless chemically activated acrylic resin using a preformed rectangular mold made of industrial silicone. During insertion, the buccal surface of the crowns was in direct contact with the mold base, avoiding coating the surface with resin.

A 5-mm area of exposed enamel was flattened2020. .International Organization for Standardization. ISO/TS 11405.:2003. Dentistry: testing of adhesion to tooth structure. Geneva: International Organization for Standardization; 2003. under constant water irrigation, using sand paper of different granulations (# 200, 400 and 600) in a metal polisher/sander.

After flattening, dental prophylaxis was performed using a rubber cup, pumice stone, water and a micromotor in low rotation for ten seconds. Each rubber cup was used on a maximum of ten crowns. Lastly, the crowns were washed with water until complete removal of the pumice paste and dried with air jets for 10 seconds. The area of the adhesive interface was delimited by placing an adhesive tape on the enamel with a circular hole of 4.5 mm diameter.

The 120 crowns were distributed according to the four types of surface treatment and three polymerization protocols, as shown in Figure 1.

Figure 1
Flowchart indicating surface treatments and polymerization protocols performed during bracket bonding.

For the phosphoric acid group (A group), the exposed enamel was conditioned with 37% Condac 37® phosphoric acid (FGM, Joinville, SC, Brazil) for 15 seconds. Afterwards, the surface was washed with a water jet (30 seconds) and dried with air jet for 5 seconds.

The phosphoric acid and the conventional Transbond XT Primer® adhesive system group (ATxt group) had the exposed enamel conditioned as A group. Next, the adhesive system was applied with a microbrush and the excess adhesive was removed with a light air jet for 2 seconds.

For the Transbond Plus Self Etching Primer® group (Tse group), the enamel surface was rubbed with the product for 3 seconds according to the manufacturer’s recommendations. The excess adhesive was removed by a light air jet for 2 seconds.

For the Scotchbond Universal® self–etching adhesive system group (SBU group), the product was applied with a microbrush for 20 seconds and the excess removed with a light air jet for 5 seconds.

Bracket bonding was performed by the same operator in all samples. The base of Roth Light® lower incisor brackets (Morelli, Sorocaba, Brazil) was coated with Transbond XT light cure adhesive paste® and the bracket was positioned on the buccal face of the crowns, parallel to the long axis of the teeth. The excess resin around the brackets was removed with an exploratory probe.

Three polymerization protocols were evaluated: Radii–Cal® (SDI, São Paulo, SP, Brazil) for 20 seconds (R20 protocol), Valo Cordless® (Ultradent, South Jordan, Utah) for 20 seconds (V20 protocol) and Valo Cordless® for 3 seconds (V3 protocol). The light was directed to the center of the bracket and the tip of the light–curing device touched the buccal surface of the bracket.

The specimens from the 12 groups were stored in distilled water (37°C) for 6 months. After this period, the shear test was performed in a Shimadzu AGS–X® universal testing machine (Shimadzu, Barueri, Brazil), in which a metal device secured the specimen so that the metal/enamel interface remained perpendicular to the horizontal plane. A blade was attached to the load cell (300 Kgf) of the machine and applied to the metal/enamel interface at a constant speed of 1 mm/min until fracture occurred.

The adhesive strength required to detach the bracket was given in Newton (N) and converted to Megapascal (MPa) according to the following formula, with A being the base area of the bracket (14 mm2):

R MPa = F N A mm 2

Failure type analysis: Adhesive Remnant Index (ARI)

The types of failure were analyzed in a stereomicroscope (Nikon SMZ800, Tokyo, Japan) with a 25× magnification and classified according to the ARI proposed by Bishara and Trulove:2121. Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part II. Findings and clinical implications. Am J Orthod Dentofacial Orthop. 1990 Sep;98(3):263-73. https://doi.org/10.1016/S0889-5406(05)81604-X
https://doi.org/10.1016/S0889-5406(05)81...
score 1 – all the resin stays on enamel, score 2 – more than 90% of the resin stays on enamel, score 3 – between 10 and 90% of the resin stays on enamel, score 4 – less than 10% resin stays on enamel, and score 5 – no resin is observed on enamel. The rating was based on the evaluation of a single operator. Intra–examiner calibration was obtained with the Kappa Index from re–evaluation of 10% of the samples after 15 days.

Degree of conversion

One hundred and twenty resin discs (n = 10/group) with an average of 0.1 mm thickness and 5 mm diameter were made by a single operator to analyze the degree of conversion of the bonding agents tested in the shear bond strength test.

A 2 mm portion of the Transbond XT adhesive paste® was placed on a microscopy glass slide (26 mm x 76 mm x 1 mm) and covered with a polyester strip. Next, a metal orthodontic bracket identical to the one used in the previous test was pressed onto the polyester strip, simulating the light pressure applied clinically during bracket bonding. The samples were subjected to the same polymerization and light exposure protocols as used for the shear test (R20, V20 and V3). After removal of the bracket and the polyester strip, the discs were created and used to assess the degree of conversion corresponding to the A group (37% phosphoric acid).

The above sequence was carried out 3 times, each time applying a drop of the Transbond XT Primer®, the Transbond Plus Self Etching Primer®, or the Scotchbond Universal® adhesive system on the microscopy glass slide, prior to adhesive paste application. The originated specimens were used to assess the degree of conversion of the monomer in the groups ATxt, Tse and SBU.

All specimens were stored for 24 hours in dark Eppendorf tubes to prevent light exposure and complete the polymerization process. The degree of conversion analysis was done in a Fourier Transform/FT–IR Infrared Spectrophotometer (IRAffinity–1®, Shimadzu, Tokyo, Japan) equipped with an attenuated total reflectance device (MIRacle HATR module with ZnSe, PIKE Technologies, Madison, USA).

The software used to measure spectra was the Shimadzu IRsolution 1.60® (Shimadzu Corporation, 2011). The results were initially normalized for baseline adjustment. All spectra were obtained under the following conditions: absorbance mode; 32 number of scans; 700 to 4000 cm–1 range; and 4 cm–1 resolution.

Since the predominant monomer in the Transbond XT Adhesive Paste® is BisGMA (Table 1), the degree of conversion (%) was calculated by the band intensity ratio for the double bonds of the methacrylate group (with energy absorption in the 1637 cm–1 region, aliphatic peak) and the band intensity of the double aromatic bonds (with energy absorption in the 1608 cm–1 region, aromatic peak), using the following formula:

GC ( % ) = 1 - R ( 1638 / 1608 ) polymerized sample R ( 1638 / 1608 ) non - polymerized sample × 100

In which R (1638/1608) represents the ratio of the values obtained for the most stable wavelength peaks (1638 nm and 1608 nm).

Power of the polymerization units

The power of the light–curing units used in this study was measured by a single operator through the analogue radiometer Led–Kondortech® (Kondortech, São Carlos, SP, Brazil), with sensitivity varying from 0 to 3000 mW/cm2. The units were fully charged during the measurement.

Data analysis

The database was built on the Statistix® software platform (Analytical Software Inc., version 8.0, 2003), and a significance level of 5% was considered in all cases. Sample power was calculated through the website www.openepi.com. Shear bond strength test results (MPa) and degree of conversion (%) were evaluated descriptively, and compared through analysis of variance (2 factors) and the Tukey’s test. The ARI results were analyzed descriptively and compared using the Kruskal–Wallis and Mann–Whitney tests.

Results

Shear bond strength test

The results of the 2 factors ANOVA for the experimental conditions are presented in Table 2. Mean bond strength values were significantly affected by the “polymerization” (p<0.05) and “surface treatment” (p < 0.05) factors. The interaction between the factors was also statistically significant (p < 0.05).

Table 2
Results of 2 factors ANOVA for the “polymerization” and “surface treatment” factors according to bond strength (*p < 0.05).

The means and standard deviations of the experimental groups are presented in Table 3 and plotted in Figure 2. The V20 (13.271 MPaA) protocol resulted in adhesive resistance values statistically higher than R20 (8.146 MPaB) and V3 (5.26 MPaC), which were statistically different from each other. Regarding the “surface treatment” factor, phosphoric acid followed by Transbond XT Primer® generated adhesive resistance values (ATxt = 13.63 MPaA) similar to Transbond Plus Self Etching Primer® (Tse = 12.38A MPa), which were statistically higher than Scotchbond Universal® (SBU = 6.37B MPa) and phosphoric acid conditioning alone (A = 3.18C MPa). The highest bond strength results were obtained for the ATxt/V20 (22.298 MPaA), Tse/V20 (17.05 MPaAB), Tse/R20 (15.33 MPaB) and ATxt/R20 (12.78 MPaBC) groups. The lowest values were obtained for the A/R20 group (1.27MPaE).

Table 3
Bond strength values (MPa) according to the factors “surface treatment” and “polymerization” (n = 10).

Figure 2
Bond strength values (MPa) ± standard deviation, according to “surface treatment” (A, ATxt, Tse, SBU) and “polymerization” (R20, V20, V3) factors.

Failure type analysis: Adhesive Remnant Index

The intra–examiner agreement for failure type analysis was considered high (k = 0.85). A significant difference (p < 0.05) in ARI scores prevalence was found for the comparisons between scores 1 and 4, 1 and 2, 4 and 5, and 2 and 5. Score 2 was the most prevalent for surface treatments A (n = 12) and ATxt (n = 19) and score 4 for Tse (n = 13) and SBU (n = 12) groups. As for the polymerization protocol, score 4 was the most prevalent in groups R20 (n = 16), while score 2 was more prevalent in groups V20 (n = 20) and V3 (n = 20). There was no significant difference between scores 2 and 4 (p = 1.000). Table 4 describes the distribution of ARI scores after the shear bond strength test by experimental group.

Table 4
Distribution of ARI scores after shear bond strength test by experimental group (n,%).

Degree of conversion

The ANOVA results for degree of conversion are presented in Table 5. Mean values were significantly affected by the “polymerization” (p < 0.05) and “surface treatment” (p < 0.05) factors. The interaction between factors was also statistically significant (p < 0.05).

Table 5
ANOVA results for the “polymerization” and “surface treatment” factors according to the degree of conversion (*p <0.05).

The mean and standard deviations for degree of conversion are shown in Table 6. The R20 polymerization protocol promoted statistically higher degree of conversion (66.67%A) than V20 (58.48%B) and V3 (45.12%C), which are statistically different from each other. Regarding the “surface treatment” factor, SBU (63.84%A) generated similar values of conversion to ATxt (59.71%A), which were statistically superior to A group (52.01%B) and Tse group (51.47%B). The highest degrees of conversion were obtained for the Tse/R20 (82.3%A), SBU/R20 (69.73%AB), and SBU/V20 (68.35%ABC) groups. The lowest values were obtained for Tse/V20 (49.38%D) and A/R20 (49.96%D) groups.

Table 6
Degree of conversion (%) according to the factors “surface treatment” and “polymerization” (n = 10).

Power of polymerization units

Table 7 shows the activation time used, the power reported by the manufacturer and the power verified by measuring the radiometer for each polymerization unit tested in the study.

Table 7
Power of the polymerization units according to the manufacturer and the calibration in the radiometer.

Sample power

Considering the mean difference between the ATxt/R20 group and the Tse/V3 group, with 95% confidence interval, the power of the sample for the shear bond strength test was estimated at 96.3%, and at 100% for the degree of conversion.

Discussion

Prior to the shear test, the samples were stored for 6 months in distilled water at 37°C. Several studies described shorter storage times such as 24 hours33. Goswami A, Mitali B, Roy B. Shear bond strength comparison of moisture-insensitive primer and self-etching primer. J Orthod Sci. 2014 Jul;3(3):89-93. https://doi.org/10.4103/2278-0203.137695
https://doi.org/10.4103/2278-0203.137695...
,44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
,1010. Grünheid T, Larson BE. Grünheid T, Larson BE. Repeated bracket bonding: conventional or self-etching primer? J World Fed Orthod. 2014;3(3):102-5. https://doi.org/10.1016/j.ejwf.2014.05.001
https://doi.org/10.1016/j.ejwf.2014.05.0...
,1212. Yadala C, Gaddam R, Arya S, Baburamreddy KV, Raju VR, Varma PK. Comparison of Shear Bond Strength of Three Self-etching Adhesives: An In-Vitro Study. J Int Oral Health. 2015 Jul;7(7):53-7. and 30 days1616. Lowder PD, Foley T, Banting DW. Bond strength of 4 orthodontic adhesives used with a caries-protective resin sealant. Am J Orthod Dentofacial Orthop. 2008 Aug;134(2):291-5. https://doi.org/10.1016/j.ajodo.2008.03.002
https://doi.org/10.1016/j.ajodo.2008.03....
, especially those testing orthodontic bracket adhesion. However, according to some authors,2222. Costa AR, Correr AB, Consani S, Giorgi MC, Vedovello SA, Vedovello Filho M et al. Influence of Water storage and bonding material on bond strength of metallic brackets to ceramic. Braz Dent J. 2015 Oct;26(5):503-6. https://doi.org/10.1590/0103-6440201300403
https://doi.org/10.1590/0103-64402013004...
bond strength decreases after 6 months of water storage. It is believed that water storage promotes a decrease in adhesion due to degradation of the adhesive interface components by hydrolysis.2323. De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M et al. A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res. 2005 Feb;84(2):118-32. https://doi.org/10.1177/154405910508400204
https://doi.org/10.1177/1544059105084002...
In addition, water may also infiltrate and weaken the mechanical properties of the polymer matrix.2424. Ito S, Hashimoto M, Wadgaonkar B, Svizero N, Carvalho RM, Yiu C et al. Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity. Biomaterials. 2005 Nov;26(33):6449-59. https://doi.org/10.1016/j.biomaterials.2005.04.052
https://doi.org/10.1016/j.biomaterials.2...
Another widely reported aging technique is thermocycling.25–,6 According to the literature,2727. Yuasa T, Iijima M, Ito S, Muguruma T, Saito T, Mizoguchi I. Effects of long-term storage and thermocycling on bond strength of two self-etching primer adhesive systems. Eur J Orthod. 2010 Jun;32(3):285-90. https://doi.org/10.1093/ejo/cjp118
https://doi.org/10.1093/ejo/cjp118...
both thermocycling and water storage are efficient in vitro methods to simulate the performance of dental materials in vivo.

Based on the main results presented in this study, the hypothesis that the surface treatment influences the adhesive strength of metallic brackets bonded to enamel was accepted. The groups treated with 37% phosphoric acid and no adhesive (A group), showed the lowest adhesive strength values (between 1.27 and 5.28 MPa), independent of the polymerization unit used; the values achieved are considered insufficient for orthodontic purposes.1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...
This contradicts the findings of Altmann et al.1414. Altmann AS, Degrazia FW, Celeste RK, Leitune VC, Samuel SM, Collares FM. Orthodontic bracket bonding without previous adhesive priming: A meta-regression analysis. Angle Orthod. 2016 May;86(3):391-8. https://doi.org/10.2319/041615-255.1
https://doi.org/10.2319/041615-255.1...
and Bazargani et al.,1313. Bazargani F, Magnuson A, Löthgren H, Kowalczyk A. Orthodontic bonding with and without primer: a randomized controlled trial. Eur J Orthod. 2016 Oct;38(5):503-7. https://doi.org/10.1093/ejo/cjv075
https://doi.org/10.1093/ejo/cjv075...
which suggest that adhesive application is a dispensable step during orthodontic bonding. However, Altmann et al.1414. Altmann AS, Degrazia FW, Celeste RK, Leitune VC, Samuel SM, Collares FM. Orthodontic bracket bonding without previous adhesive priming: A meta-regression analysis. Angle Orthod. 2016 May;86(3):391-8. https://doi.org/10.2319/041615-255.1
https://doi.org/10.2319/041615-255.1...
drew their conclusions from a systematic review in which they included in vitro studies that evaluated immediate bond strength, while the results of this study were obtained after 6 months of storage in water. The study by Bazargani et al.1313. Bazargani F, Magnuson A, Löthgren H, Kowalczyk A. Orthodontic bonding with and without primer: a randomized controlled trial. Eur J Orthod. 2016 Oct;38(5):503-7. https://doi.org/10.1093/ejo/cjv075
https://doi.org/10.1093/ejo/cjv075...
consisted of a clinical trial assessing failure rates over a 2–year period in young patients, and found significantly different rates between groups that used adhesive (4.1%) or not (12.1%).

The use of phosphoric acid followed by adhesive application (ATxt) is the treatment recommended by most clinical studies in the area.1919. Ward JD, Wolf BJ, Leite LP, Zhou J. Clinical effect of reducing curing times with high-intensity LED lights. Angle Orthod. 2015 Nov;85(6):1064-9. https://doi.org/10.2319/080714-556.1
https://doi.org/10.2319/080714-556.1...
,2828. Pandis N, Strigou S, Eliades T. Long-term failure rate of brackets bonded with plasma and high-intensity light-emitting diode curing lights:a clinical assessment. Angle Orthod. 2007 Jul;77(4):707-10. https://doi.org/10.2319/062106-253
https://doi.org/10.2319/062106-253...
The adhesive resistance values for this protocol suffered significant variations according to the polymerization unit used. This was evidenced in the samples submitted to 20–second polymerization either by Radii–Call or Valo Cordless, with averages very close to or greater than 13 MPa. According to the literature,2929. Brown CR, Way DC. Enamel loss during orthodontic bonding and subsequent loss during removal of filled and unfilled adhesives. Am J Orthod. 1978 Dec;74(6):663-71. https://doi.org/10.1016/0002-9416(78)90005-2
https://doi.org/10.1016/0002-9416(78)900...
values higher than 13 MPa might increase the risk of enamel rupture, since the cohesive forces of enamel can be exceeded. Only the group polymerized by Valo Cordless for 3 seconds approached the clinically acceptable1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...
range of 6 to 8 MPa, as opposed to the results presented by Oz et al.44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
and Lee et al.,3030. Lee HM, Kim SC, Kang KH, Chang NY. Comparison of the bonding strengths of second- and third-generation light-emitting diode light-curing units. Korean J Orthod. 2016 Nov;46(6):364-71. https://doi.org/10.4041/kjod.2016.46.6.364
https://doi.org/10.4041/kjod.2016.46.6.3...
who reported averages of 11.43 MPa and 16 MPa, respectively for the Radii–Call and Valo Cordless. The difference is probably because the two studies evaluated adhesive resistance after a very short storage period (24 hours). In addition, Lee et al.3030. Lee HM, Kim SC, Kang KH, Chang NY. Comparison of the bonding strengths of second- and third-generation light-emitting diode light-curing units. Korean J Orthod. 2016 Nov;46(6):364-71. https://doi.org/10.4041/kjod.2016.46.6.364
https://doi.org/10.4041/kjod.2016.46.6.3...
used two exposures of 3 seconds each, whereas this study used a single exposure of 3 seconds.

Regarding the adhesive resistance of the groups treated with the orthodontic self–etching adhesive system (Tse), averages higher than 13 MPa (above the ideal resistance) were observed with a 20–second polymerization. However, in spite of these values, no fractures were observed in enamel according to the Adhesive Remnant Index. Torres et al.,2626. Torres LS, Alves LA, Fava M, Di Nicoló R. Effects of thermomechanical and thermocycling on the shear bond strength of brackets to bovine enamel bonded with conventional and self-etching adhesive systems. Braz Dent Sci. 2015;18(3):98-106. https://doi.org/10.14295/bds.2015.v18i3.1152
https://doi.org/10.14295/bds.2015.v18i3....
using similar curing time and equipment, reported similarly high averages in groups submitted to aging. The values obtained with Tse cured for 3 seconds in this study were insufficient for orthodontic bonding.1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...

When comparing adhesive resistance between the conventionally treated groups (ATxt) and the orthodontic self–conditioning system (Tse) for each polymerization units, no difference was found, thus corroborating the findings of previous studies.1212. Yadala C, Gaddam R, Arya S, Baburamreddy KV, Raju VR, Varma PK. Comparison of Shear Bond Strength of Three Self-etching Adhesives: An In-Vitro Study. J Int Oral Health. 2015 Jul;7(7):53-7.,2626. Torres LS, Alves LA, Fava M, Di Nicoló R. Effects of thermomechanical and thermocycling on the shear bond strength of brackets to bovine enamel bonded with conventional and self-etching adhesive systems. Braz Dent Sci. 2015;18(3):98-106. https://doi.org/10.14295/bds.2015.v18i3.1152
https://doi.org/10.14295/bds.2015.v18i3....
,3131. Fleming PS, Johal A, Pandis N. Self-etch primers and conventional acid-etch technique for orthodontic bonding: a systematic review and meta-analysis. Am J Orthod Dentofacial Orthop. 2012 Jul;142(1):83-94. https://doi.org/10.1016/j.ajodo.2012.02.023
https://doi.org/10.1016/j.ajodo.2012.02....
No previous study compared ATxt and Tse surface treatments submitted to 3–second curing.

The self–etching adhesive system SBU, unlike Tse, was not specifically developed for orthodontic use, being used in dental substrates, methacrylate–based materials, zirconia ceramics, and metal alloys.3232. Muñoz MA, Luque I, Hass V, Reis A, Loguercio AD, Bombarda NH. Immediate bonding properties of universal adhesives to dentine. J Dent. 2013 May;41(5):404-11. https://doi.org/10.1016/j.jdent.2013.03.001
https://doi.org/10.1016/j.jdent.2013.03....
It consists of three chemical components: methacrylate monomers, silane and phosphate monomers.3333. Kim JH, Chae SY, Lee Y, Han GJ, Cho BH. Effects of multipurpose, universal adhesives on resin bonding to zirconia ceramic. Oper Dent. 2015 Jan-Feb;40(1):55-62. https://doi.org/10.2341/13-303-L
https://doi.org/10.2341/13-303-L...
According to the manufacturer, the MDP phosphate monomer allows greater adhesion to the enamel, and can be used as a metallic primer, resulting in greater adhesion in the self–conditioning technique. Despite this, the groups treated with SBU did not show adhesive resistance values above the acceptable limit; results were similar to samples treated with phosphoric acid alone when using the same polymerization units. However, it is important to note that SBU and polymerization with the Valo unit (independent of time) yield clinically acceptable results, differently from samples treated with acid alone, which showed insufficient values of resistance,1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...
independent of the polymerization protocol (unit and time).

The second hypothesis tested in this study was also accepted, as the polymerization protocol influenced the adhesive strength of metallic brackets bonded to enamel. Radii Call is a conventional polymerization unit that emits light intensity of around 1000 to 1250 mW/cm2 and is suitable for use when working with 20–second applications.44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
The Valo Cordless can function as a conventional unit when working in the standard mode, with 1000 mW/cm2 (according to the manufacturer) and 1100 mW/cm2 (according to the radiometer) emissions. The unit can also emit high light intensities in the extra–power mode, which emits 3200 mW/cm2 according to the manufacturer, but only 2600 mW/cm2 according to the radiometer. According to the manufacturers, these high–intensity units can polymerize brackets in 3 to 6 seconds.2525. Cerekja E, Cakirer B. Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling. Angle Orthod. 2011 May;81(3):510-6. https://doi.org/10.2319/071810-412.1
https://doi.org/10.2319/071810-412.1...
However, other authors3434. Gonçalves LS, Moraes RR, Ogliari FA, Boaro L, Braga RR, Consani S. Improved polymerization efficiency of methacrylate-based cements containing an iodonium salt. Dent Mater. 2013 Dec;29(12):1251-5. https://doi.org/10.1016/j.dental.2013.09.010
https://doi.org/10.1016/j.dental.2013.09...
believe that the exaggerated acceleration of chemical reactions may increase polymerization stress and interfere with enamel bonding.

In general, the highest values of adhesive strength were obtained with the Valo unit in the standard mode (20 seconds), but values were mostly similar to those obtained by the Radii unit (20 seconds). The exception was in the conventionally treated group (ATxt). When comparing 3– and 20–second curing times, independent of the polymerization unit, strength values were significantly different in groups ATxt and Tse. Previous studies44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
,1919. Ward JD, Wolf BJ, Leite LP, Zhou J. Clinical effect of reducing curing times with high-intensity LED lights. Angle Orthod. 2015 Nov;85(6):1064-9. https://doi.org/10.2319/080714-556.1
https://doi.org/10.2319/080714-556.1...
evaluating the Valo unit in the extra–power mode performed conventional enamel surface treatment in all groups (ATxt). For example, when comparing Valo (3200 mW/cm2, 3 seconds) and Elipar S10 (1600 mW/cm2, 10 seconds), Oz et al.44. Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
https://doi.org/10.1016/j.ajodo.2015.07....
found no difference in adhesive strength in vitro, or in clinical failure rates observed over 12 months. Ward et al.1919. Ward JD, Wolf BJ, Leite LP, Zhou J. Clinical effect of reducing curing times with high-intensity LED lights. Angle Orthod. 2015 Nov;85(6):1064-9. https://doi.org/10.2319/080714-556.1
https://doi.org/10.2319/080714-556.1...
compared standard and extra–power modes of the Valo unit and found no difference in clinical failure rates. However, these authors performed the extra–power mode polymerization for 6 seconds rather than 3 seconds as in the present study, which obtained significantly different adhesive strength values for the Valo for 20 seconds, the Radii for 20 seconds and the Valo for 3 seconds.

It is important to elucidate that desirable values of bracket adhesion parameters, mentioned throughout the discussion, were obtained from classic works.1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...
,2929. Brown CR, Way DC. Enamel loss during orthodontic bonding and subsequent loss during removal of filled and unfilled adhesives. Am J Orthod. 1978 Dec;74(6):663-71. https://doi.org/10.1016/0002-9416(78)90005-2
https://doi.org/10.1016/0002-9416(78)900...
However, they are little old manuscripts and provide information based on clinical situations that have been altered over time. Therefore, it is necessary to consider the temporal limitation of these parameters.

Overall, the evaluation of the Adhesive Remnant Index (ARI) in this study showed a predominance of score 2 in certain tests, and score 4 in others. Score 4 predominated in the A/R20 and A/V3 groups, indicating a weaker adhesion in the adhesive resin–enamel interface. This corroborates the low bond strength values obtained in the shear test and reinforces the hypothesis that the acid–only surface treatment causes insufficient adhesion between adhesive resin and enamel. The exception was in the A/V20 group, which showed a strong predominance of score 2, again in agreement with the results of the shear test, which showed higher bond strength values in this group.

Score 2 was more frequently observed in most of the conventionally treated groups (ATxt/V20 and ATxt/V3), showing a predominance of resin–bracket interface failures. According to Usumez (2002),3535. Uşümez S, Orhan M, Uşümez A. Laser etching of enamel for direct bonding with an Er,Cr:YSGG hydrokinetic laser system. Am J Orthod Dentofacial Orthop. 2002 Dec;122(6):649-56. https://doi.org/10.1067/mod.2002.127294
https://doi.org/10.1067/mod.2002.127294...
the literature is controversial as to the most desirable type of failure. Some authors3636. Çokakoğlu S, Nalçacı R, Üşümez S, Malkoç S. Effect of different combinations of Er: YAG laser-adhesives on enamel demineralization and bracket bond strength. Photomed Laser Surg. 2016;34(4):164-70. https://doi.org/10.1089/pho.2015.4041
https://doi.org/10.1089/pho.2015.4041...
suggest that a smaller amount of adhesive remaining in the enamel results in a shorter clinical time for cleaning and polishing the teeth after brackets removal. However, other authors3737. Raji SH, Birang R, Majdzade F, Ghorbanipour R. Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching. Dent Res J (Isfahan). 2012 May;9(3):288-93. prefer having a greater amount of adhesive remnant on the enamel surface, as the residues can be carefully removed with specific burs and this prevents cracks and fractures. This seems contradictory, considering that higher bond strength values in lower ARI scores, in general. Therefore, a greater amount of adhesive in enamel is associated with cracks and fractures of enamel during bracket removal.1515. Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
https://doi.org/10.1016/S0889-5406...

The hypotheses that “surface treatment” and “polymerization” influence the degree of conversion of bonding agents were also accepted, as well as the existence of the interaction between both factors. In general, most of the groups showed low degree of conversion values (between 49.38% and 69.73%). This results might have been found because the degree of conversion was measured at the site where the center of the bracket base had been positioned, i.e. where light incidence is the lowest.3838. Yoshida S, Namura Y, Matsuda M, Saito A, Shimizu N. Influence of light dose on bond strength of orthodontic light-cured adhesives. Eur J Orthod. 2012 Aug;34(4):493-7. https://doi.org/10.1093/ejo/cjr051
https://doi.org/10.1093/ejo/cjr051...
In addition, most studies reporting degree of conversion perform the polymerization without the bracket in place, yielding values that do not reflect clinical reality.3939. Amato PA, Martins RP, dos Santos Cruz CA, Capella MV, Martins LP. Time reduction of light curing: influence on conversion degree and microhardness of orthodontic composites. Am J Orthod Dentofacial Orthop. 2014 Jul;146(1):40-6. https://doi.org/10.1016/j.ajodo.2014.03.022
https://doi.org/10.1016/j.ajodo.2014.03....

According to some authors,3939. Amato PA, Martins RP, dos Santos Cruz CA, Capella MV, Martins LP. Time reduction of light curing: influence on conversion degree and microhardness of orthodontic composites. Am J Orthod Dentofacial Orthop. 2014 Jul;146(1):40-6. https://doi.org/10.1016/j.ajodo.2014.03.022
https://doi.org/10.1016/j.ajodo.2014.03....
a higher unit power results in a higher degree of conversion. Nonetheless, other authors4040. Verma P. Curing efficiency of three light emitting diode units at different curing profiles. Indian J Dent Res. 2016 Mar-Apr;27(2):168-73. https://doi.org/10.4103/0970-9290.183134
https://doi.org/10.4103/0970-9290.183134...
have concluded that time is more important than power for conversion of the monomers into polymers. In our study, no difference was observed between the degree of conversion when comparing groups V20 and V3; therefore, it is believed that the higher power in the polymerization unit was sufficient to compensate the reduction in polymerization time.

The Tse group was the most affected by different polymerization protocols. The degree of conversion ranged from 22.73% to 82.3% and was statistically different among R20, V20 and V3 groups. Shear bond strength values also showed significant variation (between 4.75 MPa and 17.05 MPa), which corroborates the theory that Tse appears to be more sensitive to polymerization protocol variations than the other surface treatments.

Finally, the results discussed herein are extremely important for evaluating the adhesive strength of metallic brackets bonded to enamel using different surface treatments and polymerization protocols, as well as the degree of conversion of the tested agents. However, the findings need to be complemented and validated through clinical trials.

Conclusions

Surface treatment and polymerization protocol influence both adhesive strength and the degree of conversion during metal bracket bonding to enamel; the treatment with self–etching primer is more sensitive to variations in polymerization protocols than the other surface treatments. Using phosphoric acid alone does not provide suitable bond strength or degree of conversion for bonding metal brackets to enamel.

References

  • 1
    Wang CH, Randazzo L. Evolution of imaging and management systems in orthodontics. Am J Orthod Dentofacial Orthop. 2016 Jun;149(6):798-805. https://doi.org/10.1016/j.ajodo.2016.03.016
    » https://doi.org/10.1016/j.ajodo.2016.03.016
  • 2
    Takaki T, Tamura N, Yamamoto M, Takano N, Shibahara T, Yasumura T et al. Clinical study of temporary anchorage devices for orthodontic treatment: stability of micro/mini-screws and mini-plates: experience with 455 cases. Bull Tokyo Dent Coll. 2010;51(3):151-63. https://doi.org/10.2209/tdcpublication.51.151
    » https://doi.org/10.2209/tdcpublication.51.151
  • 3
    Goswami A, Mitali B, Roy B. Shear bond strength comparison of moisture-insensitive primer and self-etching primer. J Orthod Sci. 2014 Jul;3(3):89-93. https://doi.org/10.4103/2278-0203.137695
    » https://doi.org/10.4103/2278-0203.137695
  • 4
    Oz AA, Oz AZ, Arici S. In-vitro bond strengths and clinical failure rates of metal brackets bonded with different light-emitting diode units and curing times. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):212-6. https://doi.org/10.1016/j.ajodo.2015.07.036
    » https://doi.org/10.1016/j.ajodo.2015.07.036
  • 5
    Songra G, Clover M, Atack NE, Ewings P, Sherriff M, Sandy JR et al. Comparative assessment of alignment efficiency and space closure of active and passive self-ligating vs conventional appliances in adolescents: a single-center randomized controlled trial. Am J Orthod Dentofacial Orthop. 2014 May;145(5):569-78. https://doi.org/10.1016/j.ajodo.2013.12.024
    » https://doi.org/10.1016/j.ajodo.2013.12.024
  • 6
    Bellini H, Moyano J, Gil J, Puigdollers A. Comparison of the superelasticity of different nickel-titanium orthodontic archwires and the loss of their properties by heat treatment. J Mater Sci Mater Med. 2016 Oct;27(10):158. https://doi.org/10.1007/s10856-016-5767-5
    » https://doi.org/10.1007/s10856-016-5767-5
  • 7
    Dominguez GC, Tortamano A, Lopes LV, Catharino PC, Morea C. A comparative clinical study of the failure rate of orthodontic brackets bonded with two adhesive systems: conventional and self-etching primer (SEP). Dental Press J Orthod. 2013 Mar-Apr;18(2):55-60. https://doi.org/10.1590/S2176-94512013000200014
    » https://doi.org/10.1590/S2176-94512013000200014
  • 8
    Mohammed RE, Abass S, Abubakr NH, Mohammed ZM. Comparing orthodontic bond failures of light-cured composite resin with chemical-cured composite resin: A 12-month clinical trial. Am J Orthod Dentofacial Orthop. 2016 Aug;150(2):290-4. https://doi.org/10.1016/j.ajodo.2016.02.013
    » https://doi.org/10.1016/j.ajodo.2016.02.013
  • 9
    Buonocore MG. A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces. J Dent Res. 1955 Dec;34(6):849-53. https://doi.org/10.1177/00220345550340060801
    » https://doi.org/10.1177/00220345550340060801
  • 10
    Grünheid T, Larson BE. Grünheid T, Larson BE. Repeated bracket bonding: conventional or self-etching primer? J World Fed Orthod. 2014;3(3):102-5. https://doi.org/10.1016/j.ejwf.2014.05.001
    » https://doi.org/10.1016/j.ejwf.2014.05.001
  • 11
    Esteves CM, Ota-Tsuzuki C, Reis AF, Rodrigues JA. Antibacterial activity of various self-etching adhesive systems against oral streptococci. Oper Dent. 2010 Jul-Aug;35(4):448-53. https://doi.org/10.2341/09-297-L
    » https://doi.org/10.2341/09-297-L
  • 12
    Yadala C, Gaddam R, Arya S, Baburamreddy KV, Raju VR, Varma PK. Comparison of Shear Bond Strength of Three Self-etching Adhesives: An In-Vitro Study. J Int Oral Health. 2015 Jul;7(7):53-7.
  • 13
    Bazargani F, Magnuson A, Löthgren H, Kowalczyk A. Orthodontic bonding with and without primer: a randomized controlled trial. Eur J Orthod. 2016 Oct;38(5):503-7. https://doi.org/10.1093/ejo/cjv075
    » https://doi.org/10.1093/ejo/cjv075
  • 14
    Altmann AS, Degrazia FW, Celeste RK, Leitune VC, Samuel SM, Collares FM. Orthodontic bracket bonding without previous adhesive priming: A meta-regression analysis. Angle Orthod. 2016 May;86(3):391-8. https://doi.org/10.2319/041615-255.1
    » https://doi.org/10.2319/041615-255.1
  • 15
    Whitlock BO 3rd, Eick JD, Ackerman RJ Jr, Glaros AG, Chappell RP. Shear strength of ceramic brackets bonded to porcelain. Am J Orthod Dentofacial Orthop. 1994 Oct;106(4):358-64. https://doi.org/10.1016/S0889-5406(94)70056-7
    » https://doi.org/10.1016/S0889-5406
  • 16
    Lowder PD, Foley T, Banting DW. Bond strength of 4 orthodontic adhesives used with a caries-protective resin sealant. Am J Orthod Dentofacial Orthop. 2008 Aug;134(2):291-5. https://doi.org/10.1016/j.ajodo.2008.03.002
    » https://doi.org/10.1016/j.ajodo.2008.03.002
  • 17
    Pinto CM, Ferreira JT, Matsumoto MA, Borsatto MC, Silva RA, Romano FL. Evaluation of different LED light-curing devices for bonding metallic orthodontic brackets. Braz Dent J. 2011;22(3):249-53. https://doi.org/10.1590/S0103-64402011000300012
    » https://doi.org/10.1590/S0103-64402011000300012
  • 18
    McCusker N, Lee SM, Robinson S, Patel N, Sandy JR, Ireland AJ. Light curing in orthodontics; should we be concerned? Dent Mater. 2013 Jun;29(6):e85-90. https://doi.org/10.1016/j.dental.2013.03.023
    » https://doi.org/10.1016/j.dental.2013.03.023
  • 19
    Ward JD, Wolf BJ, Leite LP, Zhou J. Clinical effect of reducing curing times with high-intensity LED lights. Angle Orthod. 2015 Nov;85(6):1064-9. https://doi.org/10.2319/080714-556.1
    » https://doi.org/10.2319/080714-556.1
  • 20
    .International Organization for Standardization. ISO/TS 11405.:2003. Dentistry: testing of adhesion to tooth structure. Geneva: International Organization for Standardization; 2003.
  • 21
    Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Part II. Findings and clinical implications. Am J Orthod Dentofacial Orthop. 1990 Sep;98(3):263-73. https://doi.org/10.1016/S0889-5406(05)81604-X
    » https://doi.org/10.1016/S0889-5406(05)81604-X
  • 22
    Costa AR, Correr AB, Consani S, Giorgi MC, Vedovello SA, Vedovello Filho M et al. Influence of Water storage and bonding material on bond strength of metallic brackets to ceramic. Braz Dent J. 2015 Oct;26(5):503-6. https://doi.org/10.1590/0103-6440201300403
    » https://doi.org/10.1590/0103-6440201300403
  • 23
    De Munck J, Van Landuyt K, Peumans M, Poitevin A, Lambrechts P, Braem M et al. A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res. 2005 Feb;84(2):118-32. https://doi.org/10.1177/154405910508400204
    » https://doi.org/10.1177/154405910508400204
  • 24
    Ito S, Hashimoto M, Wadgaonkar B, Svizero N, Carvalho RM, Yiu C et al. Effects of resin hydrophilicity on water sorption and changes in modulus of elasticity. Biomaterials. 2005 Nov;26(33):6449-59. https://doi.org/10.1016/j.biomaterials.2005.04.052
    » https://doi.org/10.1016/j.biomaterials.2005.04.052
  • 25
    Cerekja E, Cakirer B. Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling. Angle Orthod. 2011 May;81(3):510-6. https://doi.org/10.2319/071810-412.1
    » https://doi.org/10.2319/071810-412.1
  • 26
    Torres LS, Alves LA, Fava M, Di Nicoló R. Effects of thermomechanical and thermocycling on the shear bond strength of brackets to bovine enamel bonded with conventional and self-etching adhesive systems. Braz Dent Sci. 2015;18(3):98-106. https://doi.org/10.14295/bds.2015.v18i3.1152
    » https://doi.org/10.14295/bds.2015.v18i3.1152
  • 27
    Yuasa T, Iijima M, Ito S, Muguruma T, Saito T, Mizoguchi I. Effects of long-term storage and thermocycling on bond strength of two self-etching primer adhesive systems. Eur J Orthod. 2010 Jun;32(3):285-90. https://doi.org/10.1093/ejo/cjp118
    » https://doi.org/10.1093/ejo/cjp118
  • 28
    Pandis N, Strigou S, Eliades T. Long-term failure rate of brackets bonded with plasma and high-intensity light-emitting diode curing lights:a clinical assessment. Angle Orthod. 2007 Jul;77(4):707-10. https://doi.org/10.2319/062106-253
    » https://doi.org/10.2319/062106-253
  • 29
    Brown CR, Way DC. Enamel loss during orthodontic bonding and subsequent loss during removal of filled and unfilled adhesives. Am J Orthod. 1978 Dec;74(6):663-71. https://doi.org/10.1016/0002-9416(78)90005-2
    » https://doi.org/10.1016/0002-9416(78)90005-2
  • 30
    Lee HM, Kim SC, Kang KH, Chang NY. Comparison of the bonding strengths of second- and third-generation light-emitting diode light-curing units. Korean J Orthod. 2016 Nov;46(6):364-71. https://doi.org/10.4041/kjod.2016.46.6.364
    » https://doi.org/10.4041/kjod.2016.46.6.364
  • 31
    Fleming PS, Johal A, Pandis N. Self-etch primers and conventional acid-etch technique for orthodontic bonding: a systematic review and meta-analysis. Am J Orthod Dentofacial Orthop. 2012 Jul;142(1):83-94. https://doi.org/10.1016/j.ajodo.2012.02.023
    » https://doi.org/10.1016/j.ajodo.2012.02.023
  • 32
    Muñoz MA, Luque I, Hass V, Reis A, Loguercio AD, Bombarda NH. Immediate bonding properties of universal adhesives to dentine. J Dent. 2013 May;41(5):404-11. https://doi.org/10.1016/j.jdent.2013.03.001
    » https://doi.org/10.1016/j.jdent.2013.03.001
  • 33
    Kim JH, Chae SY, Lee Y, Han GJ, Cho BH. Effects of multipurpose, universal adhesives on resin bonding to zirconia ceramic. Oper Dent. 2015 Jan-Feb;40(1):55-62. https://doi.org/10.2341/13-303-L
    » https://doi.org/10.2341/13-303-L
  • 34
    Gonçalves LS, Moraes RR, Ogliari FA, Boaro L, Braga RR, Consani S. Improved polymerization efficiency of methacrylate-based cements containing an iodonium salt. Dent Mater. 2013 Dec;29(12):1251-5. https://doi.org/10.1016/j.dental.2013.09.010
    » https://doi.org/10.1016/j.dental.2013.09.010
  • 35
    Uşümez S, Orhan M, Uşümez A. Laser etching of enamel for direct bonding with an Er,Cr:YSGG hydrokinetic laser system. Am J Orthod Dentofacial Orthop. 2002 Dec;122(6):649-56. https://doi.org/10.1067/mod.2002.127294
    » https://doi.org/10.1067/mod.2002.127294
  • 36
    Çokakoğlu S, Nalçacı R, Üşümez S, Malkoç S. Effect of different combinations of Er: YAG laser-adhesives on enamel demineralization and bracket bond strength. Photomed Laser Surg. 2016;34(4):164-70. https://doi.org/10.1089/pho.2015.4041
    » https://doi.org/10.1089/pho.2015.4041
  • 37
    Raji SH, Birang R, Majdzade F, Ghorbanipour R. Evaluation of shear bond strength of orthodontic brackets bonded with Er-YAG laser etching. Dent Res J (Isfahan). 2012 May;9(3):288-93.
  • 38
    Yoshida S, Namura Y, Matsuda M, Saito A, Shimizu N. Influence of light dose on bond strength of orthodontic light-cured adhesives. Eur J Orthod. 2012 Aug;34(4):493-7. https://doi.org/10.1093/ejo/cjr051
    » https://doi.org/10.1093/ejo/cjr051
  • 39
    Amato PA, Martins RP, dos Santos Cruz CA, Capella MV, Martins LP. Time reduction of light curing: influence on conversion degree and microhardness of orthodontic composites. Am J Orthod Dentofacial Orthop. 2014 Jul;146(1):40-6. https://doi.org/10.1016/j.ajodo.2014.03.022
    » https://doi.org/10.1016/j.ajodo.2014.03.022
  • 40
    Verma P. Curing efficiency of three light emitting diode units at different curing profiles. Indian J Dent Res. 2016 Mar-Apr;27(2):168-73. https://doi.org/10.4103/0970-9290.183134
    » https://doi.org/10.4103/0970-9290.183134

Publication Dates

  • Publication in this collection
    11 June 2018
  • Date of issue
    2018

History

  • Received
    02 Feb 2018
  • Reviewed
    07 May 2018
  • Accepted
    11 May 2018
Sociedade Brasileira de Pesquisa Odontológica - SBPqO Av. Prof. Lineu Prestes, 2227, 05508-000 São Paulo SP - Brazil, Tel. (55 11) 3044-2393/(55 11) 9-7557-1244 - São Paulo - SP - Brazil
E-mail: office.bor@ingroup.srv.br