Acessibilidade / Reportar erro

Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis

Abstract

BACKGROUND:

Computed tomography (CT) accounts for 13% of all radiological examinations in the United States and 40-70% of the radiation that patients receive. Even with the advent of magnetic resonance imaging (MRI), CT continues to be the gold standard for diagnosing bone fractures. There is uncertainty as to whether CT with a low radiation dose has a fracture detection rate similar to that of standard-dose CT.

OBJECTIVE:

To determine the detection rate of low-dose radiation CT and standard-dose radiation CT for fractures, in patients with suspected fractures.

DESIGN AND SETTING:

Systematic review of comparative studies on diagnostic accuracy within the evidence-based health program at a federal university in São Paulo (SP), Brazil.

METHODS:

We searched the electronic databases Cochrane Library, MEDLINE, EMBASE and LILACS up to June 29, 2020, for studies evaluating the detection rates of low-dose CT and standard-dose CT for diagnosing bone fractures. The Research Triangle Institute (RTI) item bank tool was used for methodological quality evaluation.

RESULTS:

The fracture detection rate according to the number of bones evaluated, using CT with low-dose radiation was 20.3%, while with standard-dose radiation it was 19.2%, and the difference between the methods was not significant. The fracture detection rate according to the number of patients, using CT with low-dose radiation was 56.0%, while with standard-dose radiation it was 58.7%, and this difference between the methods was not significant, either.

CONCLUSION:

CT with low-dose radiation presented detection rates similar to those of CT with standard-dose radiation, regardless of the bones evaluated.

REGISTRATION NUMBER:

CRD42019148491 at the PROSPERO database.

KEYWORDS (MeSH terms):
Fractures, bone; Radiation dosage; Tomography, X-ray computed

AUTHORS’ KEYWORDS:
Low-dose CT; Standard-dose CT CT scan; X-ray; ALARA; Detection rate


INTRODUCTION

Ionizing radiation such as X-rays is a singular form of energy that surmounts the binding energy of electrons that orbit atoms and molecules.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...
In biological material exposed to X-rays, the most common consequential scenario is that this creates hydroxyl radicals from interactions between X-rays and water molecules. These radicals, in turn, interact with deoxyribonucleic acid (DNA) to cause breakage of bonds or damage to the base.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...
Thus, mutations, chromosomal translocations and fusions between genes can occur, which in some cases may lead to cancer.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...

All X-ray-based imaging methods have the characteristic in common of a trade-off between image quality and radiation dose, since all forms of ionizing radiation can damage tissues.22. Brisco J, Fuller K, Lee N, Andrew D. Cone beam computed tomography for imaging orbital trauma--image quality and radiation dose compared with conventional multislice computed tomography. Br J Oral Maxillofac Surg. 2014;52(1):76-80. PMID: 24139635; https://doi.org/10.1016/j. bjoms.2013.09.011.
https://doi.org/10.1016/j.bjoms.2013.09....
In patients undergoing radiographic and/or tomographic monitoring, the patient’s exposure to radiation needs to be considered, and this poses a challenge to radiologists regarding dose reduction.33. Kloth JK, Rickert M, Gotterbarm T, et al. Pelvic X-ray examinations in follow-up of hip arthroplasty or femoral osteosynthesis--dose reduction and quality criteria. Eur J Radiol. 2015;84:915-20. PMID: 25715664; https://doi.org/10.1016/j.ejrad.2015.02.001.
https://doi.org/10.1016/j.ejrad.2015.02....
,44. Garcia-Sanchez AJ, Garcia Angosto E, Llor JL, Serna Berna A, Ramos D. Machine Learning Techniques Applied to Dose Prediction in Computed Tomography Tests. Sensors (Basel). 2019;19(23):5116. PMID: 31766708; https://doi.org/10.3390/s19235116.
https://doi.org/10.3390/s19235116...

The main concern in diagnostic imaging is that a stochastic lesion of radiation-induced cancer could develop, which can occur with any radiation dose.55. Alshamari M, Geijer M, Norrman E, Geijer H. Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality. Acta Radiol. 2014;55(7):824-32. PMID: 24215904; https://doi.org/10.1177/0284185113509615.
https://doi.org/10.1177/0284185113509615...
,66. Banerjee P, Thomas M. CT scans to exclude spine fractures in children after negative radiographs may lead to increase in future cancer risk. Eur J Orthop Surg Traumatol. 2019;29(5):983-8. PMID: 30941632; https:// doi.org/10.1007/s00590-019-02396-5.
https://doi.org/10.1007/s00590-019-02396...
,77. Tien HC, Tremblay LN, Rizoli SB, et al. Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007;62(1):151-6. PMID: 17215747; https://doi.org/10.1097/TA.0b013e31802d9700.
https://doi.org/10.1097/TA.0b013e31802d9...
Conversely, deterministic effects occur only when the threshold has been exceeded and, above that, the incidence and severity of the injury increase with the radiation dose.66. Banerjee P, Thomas M. CT scans to exclude spine fractures in children after negative radiographs may lead to increase in future cancer risk. Eur J Orthop Surg Traumatol. 2019;29(5):983-8. PMID: 30941632; https:// doi.org/10.1007/s00590-019-02396-5.
https://doi.org/10.1007/s00590-019-02396...
,77. Tien HC, Tremblay LN, Rizoli SB, et al. Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007;62(1):151-6. PMID: 17215747; https://doi.org/10.1097/TA.0b013e31802d9700.
https://doi.org/10.1097/TA.0b013e31802d9...
It also needs to be taken into account that the pediatric population is 10 times more sensitive to radiation than adults.88. Moritz JD, Hoffmann B, Sehr D, et al. Evaluation of ultra-low dose CT in the diagnosis of pediatric-like fractures using an experimental animal study. Korean J Radiol. 2012;13(2):165-73. PMID: 22438683; https://doi. org/10.3348/kjr.2012.13.2.165.
https://doi.org/10.3348/kjr.2012.13.2.16...

To date, no safe dose of ionizing radiation, below which there is no risk of cell damage and subsequent risk of cancer, has been established.99. Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing Radiation Dose in Computed Tomography of Articular Fractures. J Orthop Trauma. 2017;31(8):401-6. PMID: 28394843; https://doi.org/10.1097/ BOT.0000000000000861.
https://doi.org/10.1097/BOT.000000000000...
,1010. Sollmann N, Mei K, Hedderich DM, et al. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures. Eur Radiol. 2019;29(7):3606-16. PMID: 30903337; https://doi.org/10.1007/s00330-019-06090-2.
https://doi.org/10.1007/s00330-019-06090...
However, it has been estimated in the United States that about 1.5%-2.0% of all malignancies can be attributed to radiation from computed tomography (CT) scans.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...
,66. Banerjee P, Thomas M. CT scans to exclude spine fractures in children after negative radiographs may lead to increase in future cancer risk. Eur J Orthop Surg Traumatol. 2019;29(5):983-8. PMID: 30941632; https:// doi.org/10.1007/s00590-019-02396-5.
https://doi.org/10.1007/s00590-019-02396...
Taking all imaging examinations into account, this proportion ranges from 0.6% to 3.6%.1111. Kim SJ, Bista AB, Min YG, et al. Usefulness of low dose chest CT for initial evaluation of blunt chest trauma [published correction appears in Medicine (Baltimore). 2017;96(23):e7234]. Medicine (Baltimore). 2017;96(2):e5888. PMID: 28079832; https://doi.org/10.1097/ MD.0000000000005888.
https://doi.org/10.1097/MD.0000000000005...
The risk of cancer increases by 0.01% for each mSv emitted in imaging tests.1212. Lemburg SP, Peters SA, Roggenland D, Nicolas V, Heyer CM. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries. AJR Am J Roentgenol. 2010;195(6):1411-7. PMID: 21098203; https://doi.org/10.2214/AJR.10.4616.
https://doi.org/10.2214/AJR.10.4616...

Thus, there is a growing awareness of the need to use the lowest possible radiation dose level that is capable of providing appropriate diagnostic information, also known as the ALARA principle (As Low As Reasonably Achievable).99. Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing Radiation Dose in Computed Tomography of Articular Fractures. J Orthop Trauma. 2017;31(8):401-6. PMID: 28394843; https://doi.org/10.1097/ BOT.0000000000000861.
https://doi.org/10.1097/BOT.000000000000...
,1111. Kim SJ, Bista AB, Min YG, et al. Usefulness of low dose chest CT for initial evaluation of blunt chest trauma [published correction appears in Medicine (Baltimore). 2017;96(23):e7234]. Medicine (Baltimore). 2017;96(2):e5888. PMID: 28079832; https://doi.org/10.1097/ MD.0000000000005888.
https://doi.org/10.1097/MD.0000000000005...
,1212. Lemburg SP, Peters SA, Roggenland D, Nicolas V, Heyer CM. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries. AJR Am J Roentgenol. 2010;195(6):1411-7. PMID: 21098203; https://doi.org/10.2214/AJR.10.4616.
https://doi.org/10.2214/AJR.10.4616...
,1313. Rozema R, Doff MH, van Ooijen PM, et al. Diagnostic reliability of low dose multidetector CT and cone beam CT in maxillofacial trauma-an experimental blinded and randomized study. Dentomaxillofac Radiol. 2018;47(8):20170423. PMID: 29745761; https://doi.org/10.1259/ dmfr.20170423.
https://doi.org/10.1259/dmfr.20170423...
,1414. Ippolito D, Besostri V, Bonaffini PA, et al. Diagnostic value of whole-body low-dose computed tomography (WBLDCT) in bone lesions detection in patients with multiple myeloma (MM). Eur J Radiol. 2013;82(12):2322-7. PMID: 24074647; https://doi.org/10.1016/j.ejrad.2013.08.036.
https://doi.org/10.1016/j.ejrad.2013.08....
,1515. Widmann G, Juranek D, Waldenberger F, et al. Influence of Ultra-Low-Dose and Iterative Reconstructions on the Visualization of Orbital Soft Tissues on Maxillofacial CT. AJNR Am J Neuroradiol. 2017;38(8):1630-5. PMID: 28596194; https://doi.org/10.3174/ajnr.A5239.
https://doi.org/10.3174/ajnr.A5239...
,1616. Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
https://doi.org/10.1097/MD.0000000000011...
,1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
,1919. Lee RK, Chu WC, Graham CA, Rainer TH, Ahuja AT. Knowledge of radiation exposure in common radiological investigations: a comparison between radiologists and non-radiologists. Emerg Med J. 2012;29(4):306-8. PMID: 21873321; https://doi.org/10.1136/emermed-2011-200481.
https://doi.org/10.1136/emermed-2011-200...
,2020. Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380(9840):499-505. PMID: 22681860; https://doi.org/10.1016/S0140-6736(12)60815-0.
https://doi.org/10.1016/S0140-6736(12)60...
,2121. Andresz S, Morgan J, Croüail P, Vermeersch F. Conclusions and recommendations from the 17th Workshop of the European ALARA Network ‘ALARA in emergency exposure situations’. J Radiol Prot. 2018;38(1):434-9. PMID: 29339579; https://doi.org/10.1088/1361-6498/aaa86b.
https://doi.org/10.1088/1361-6498/aaa86b...
,2222. Kocyigit A, Serinken M, Ceven Z, et al. A strategy to optimize CT use in children with mild blunt head trauma utilizing clinical risk stratification; could we improve CT use in children with mild head injury? Clin Imaging. 2014;38(3):236-40. PMID: 24444707; https://doi.org/10.1016/j. clinimag.2013.12.004.
https://doi.org/10.1016/j.clinimag.2013....
,2323. Kahn J, Kaul D, Böning G, et al. Quality and Dose Optimized CT Trauma Protocol - Recommendation from a University Level-I Trauma Center. Qualitäts- und dosisoptimiertes CT-Polytraumaprotokoll – Empfehlung eines universitären Level-I Traumazentrums. Rofo. 2017;189(9):844-54. PMID: 28651263; https://doi.org/10.1055/s-0043-108996.
https://doi.org/10.1055/s-0043-108996...
,2424. Kim PK, Zhu X, Houseknecht E, et al. Effective radiation dose from radiologic studies in pediatric trauma patients. World J Surg. 2005;29(12):1557-62. PMID: 16331342; https://doi.org/10.1007/s00268-005-0106-x.
https://doi.org/10.1007/s00268-005-0106-...

CT is the gold standard for diagnosing fractures,1010. Sollmann N, Mei K, Hedderich DM, et al. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures. Eur Radiol. 2019;29(7):3606-16. PMID: 30903337; https://doi.org/10.1007/s00330-019-06090-2.
https://doi.org/10.1007/s00330-019-06090...
,2525. Duane TM, Mayglothling J, Wilson SP, et al. National Emergency X-Radiography Utilization Study criteria is inadequate to rule out fracture after significant blunt trauma compared with computed tomography. J Trauma. 2011;70(4):829-31. PMID: 21610391; https://doi.org/10.1097/ TA.0b013e31820ea6b3.
https://doi.org/10.1097/TA.0b013e31820ea...
,2626. Haapamäki VV, Kiuru MJ, Mustonen AO, Koskinen SK. Multidetector computed tomography in acute joint fractures. Acta Radiol. 2005;46(6):587-98. PMID: 16334840; https://doi.org/10.1080/02841850510021634.
https://doi.org/10.1080/0284185051002163...
,2727. Konda SR, Goch AM, Haglin J, Egol KA. Ultralow-Dose CT (REDUCTION Protocol) for Extremity Fracture Evaluation Is as Safe and Effective as Conventional CT: An Evaluation of Quality Outcomes. J Orthop Trauma. 2018;32(5):216-222. PMID: 29401094; https://doi.org/10.1097/ BOT.0000000000001137.
https://doi.org/10.1097/BOT.000000000000...
characterizing them in greater detail, identifying hidden fractures and showing incomplete union.2727. Konda SR, Goch AM, Haglin J, Egol KA. Ultralow-Dose CT (REDUCTION Protocol) for Extremity Fracture Evaluation Is as Safe and Effective as Conventional CT: An Evaluation of Quality Outcomes. J Orthop Trauma. 2018;32(5):216-222. PMID: 29401094; https://doi.org/10.1097/ BOT.0000000000001137.
https://doi.org/10.1097/BOT.000000000000...
,2828. Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using CT in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668-73. PMID: 27909130; https://doi.org/10.1302/0301-620X.98B12.BJJ-2016-0336.R1.
https://doi.org/10.1302/0301-620X.98B12....
In musculoskeletal radiology, low-dose CT has shown good results in studies with pre and postoperative scoliosis evaluations, as well as in diagnosing lytic injuries and fractures in patients with multiple myeloma.55. Alshamari M, Geijer M, Norrman E, Geijer H. Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality. Acta Radiol. 2014;55(7):824-32. PMID: 24215904; https://doi.org/10.1177/0284185113509615.
https://doi.org/10.1177/0284185113509615...
,2929. Zacchino M, Bonaffini PA, Corso A, et al. Inter-observer agreement for the evaluation of bone involvement on Whole Body Low Dose Computed Tomography (WBLDCT) in Multiple Myeloma (MM). Eur Radiol. 2015;25(11):3382-9. PMID: 25987427; https://doi.org/10.1007/ s00330-015-3733-0.
https://doi.org/10.1007/s00330-015-3733-...
,3030. Alshamari M, Geijer M, Norrman E, et al. Low dose CT of the lumbar spine compared with radiography: a study on image quality with implications for clinical practice. Acta Radiol. 2016;57(5):602-11. PMID: 26221055; https://doi.org/10.1177/0284185115595667.
https://doi.org/10.1177/0284185115595667...
However, when metallic components are present in the bones studied, standard-dose CT scans have better image quality, with fewer artifacts, than low-dose CT scans.3131. Finkenstaedt T, Morsbach F, Calcagni M, et al. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography. Invest Radiol. 2014;49(8):532-9. PMID: 24691141; https://doi.org/10.1097/ RLI.0000000000000052.
https://doi.org/10.1097/RLI.000000000000...

OBJECTIVES

The aim of this study was to determine the detection rates of computed tomography with low radiation dose and computed tomography with standard radiation dose for fractures, independent of the bone suspected, in patients with suspected fractures.

METHODS

Study model

The study model followed the guidelines for systematic reviews of diagnostic accuracy studies, in the Cochrane Diagnostic Reviewer’s Handbook version 5.1.

Inclusion criteria

The search of the literature was performed in accordance with the guidelines for Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Studies evaluating the diagnostic accuracy and detection rates of fractures in patients with suspicion of fractures, evaluated using low-dose CT and standard-dose CT were included regardless of publication status and regardless of severity and time of disease. We did not put any restrictions on patient age, origin, language or publication status of the study. There was no exclusion regarding population size or patient age. In cases of missing information, the authors were contacted by email.

Participants

The participants in this study were men and women of all ages with suspected bone fractures who underwent low-dose CT or standard-dose CT.

Selection of studies and data extraction

The studies selected were those that were potentially eligible for inclusion in terms of relevant articles or abstracts from reference journals. Two authors performed independent selections for eligibility. In cases of disagreement, a third author was consulted. Data extraction was performed using a standardized form.

Evaluation of methodological quality

Eligible studies with a control group were evaluated using the QUADAS 2 tool (Quality Assessment of Diagnostic Accuracy Studies).3232. Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529-536. PMID: 22007046; https://doi.org/10.7326/0003-4819-155-8-201110180-00009.
https://doi.org/10.7326/0003-4819-155-8-...
In all eligible studies, the RTI Item Bank questionnaire was used. This is a tool that focuses on evaluation of biases and precision).3333. Margulis AV, Pladevall M, Riera-Guardia N, et al. Quality assessment of observational studies in a drug-safety systematic review, comparison of two tools: the Newcastle-Ottawa Scale and the RTI item bank. Clin Epidemiol. 2014;6:359-68. PMID: 25336990; https://doi.org/10.2147/CLEP.S66677.
https://doi.org/10.2147/CLEP.S66677...
,3434. Viswanathan M, Berkman ND. Development of the RTI item bank on risk of bias and precision of observational studies. J Clin Epidemiol. 2012;65(2):163-78. PMID: 21959223; https://doi.org/10.1016/j. jclinepi.2011.05.008.
https://doi.org/10.1016/j.jclinepi.2011....

All forest plots were made using the Review Manager software (RevMan), version 5.3, in order to obtain sensitivity and specificity values and the respective 95% confidence intervals (CI). We expressed dichotomous data as odds ratios (OR) with a 95% CI and continuous data as mean differences (MDs) with 95% CI. The study was approved by our institutional review board, under the approval number 7184070819, dated October 2, 2019. The review was approved by the PROSPERO database. No funding or support was provided for this study.

Research methods for choosing studies

A thorough systematic search of the literature was performed in June 2020, in the PubMed, EMBASE, Cochrane Library and LILACS online scientific publication databases, for all original-language publications. The search was conducted using the medical subject headings (MeSH). The MeSH terms used included the following: fractures, bone; radiation dosage; tomography, X-ray computed. The reference lists of the studies included and the main reviews on the subject were also evaluated. Manual searches were also carried out in the lists of references. The full search strategy is presented in Table 1.

Table 1
Search strategies used in each of the databases

RESULTS

Studies selected

The search for this systematic review yielded 468 studies using the following MeSH terms: fractures, bone; radiation dosage; tomography, X-ray computed.

There were no studies in which low-dose CT and standard-dose CT were performed on the same patient. Also, no study had a control group. Therefore, it was not possible to assess accuracy, and only the detection rate could be evaluated in the meta-analysis. A total of five studies fulfilled the inclusion criteria and were included in qualitative analysis (Figure 1).1616. Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
https://doi.org/10.1097/MD.0000000000011...
,1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
,3535. Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
https://doi.org/10.3174/ajnr.A0608...
,3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
Two studies did not provide all the data.1616. Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
https://doi.org/10.1097/MD.0000000000011...
,3535. Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
https://doi.org/10.3174/ajnr.A0608...
Konda et al. was not used because it did not have the necessary blinding for inclusion in this systematic review.2828. Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using CT in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668-73. PMID: 27909130; https://doi.org/10.1302/0301-620X.98B12.BJJ-2016-0336.R1.
https://doi.org/10.1302/0301-620X.98B12....

Figure 1
Summary of the study selection process.

Analysis on the studies

Lee et al. conducted two studies: one published in 20171717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
and another in 2018.1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
In both, the period between January and September 2016 was assessed. However, these studies were performed using different devices, with 64 channels and 320 channels, respectively. In Lee et al.,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
there were evaluations by two doctors: one from the emergency department and one radiologist. For the statistical evaluation, we use the data from the radiologist because this specialist has the responsibility for issuing reports.

Four studies reported the numbers of patients evaluated and how many had fractures.1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
,3535. Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
https://doi.org/10.3174/ajnr.A0608...
,3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
Four studies reported the numbers of bones evaluated and how many had fractures.1616. Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
https://doi.org/10.1097/MD.0000000000011...
,1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
,3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
There was no study with a control group.

All the studies reported that the reduction in the radiation dosage of the CT scans was around 50%. The CT devices, bones evaluated and radiation dosages in the studies reviewed are shown in Table 2.1616. Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
https://doi.org/10.1097/MD.0000000000011...
,1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
,3535. Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
https://doi.org/10.3174/ajnr.A0608...
,3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...

Table 2
Radiation doses used in computed tomography in each of the studies reviewed

Detection rate in relation to number of bones

Bone evaluations were provided and cited with regard to each method, in four studies: Jin et al.,1616. Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
https://doi.org/10.1097/MD.0000000000011...
Lee et al.,1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
Lee et al.1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
and Yi et al.3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
A total of 7719 bones were evaluated. Out of the 3876 bones evaluated by means of standard-dose CT, 744 had fractures: a detection rate of 19.2%. Out of the 3,843 bones evaluated by means of low-dose CT, 782 showed fractures: a detection rate of 20.3%. All of this information is shown in Figure 2.

Figure 2
Forest plot: comparison demonstrating that there was no significant difference between low-dose CT and standard-dose CT regarding the detection rate for bone fractures.

Detection rate in relation to number of patients

Patient assessments were provided and cited with regard to each method, in four studies: Lee et al.,1717. Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
https://doi.org/10.1259/bjr.20170181...
Lee et al.,1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
Mulkens et al.3535. Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
https://doi.org/10.3174/ajnr.A0608...
and Yi et al.3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
A total of 996 patients were evaluated. Out of the 453 patients assessed by means of standard-dose CT, 266 had fractures: a detection rate of 58.7%. Out of the 543 patients evaluated by means of low-dose CT, 304 had fractures: a detection rate of 56.0%. All of this information is shown in Figure 3.

Figure 3
Forest plot: comparison demonstrating that there was no significant difference between low-dose CT and standard-dose CT regarding the detection rate for patients with fractures.

DISCUSSION

The detection rate of low-dose CT in relation to evaluation of the number of fractured bones was 20.3%, while standarddose CT yielded a rate of 19.2%. The difference between the methods was not significant. The detection rate of low-dose CT in relation to evaluation of the number of patients with fractures was 56.0%, while standard-dose CT yielded a rate of 58.7%. Here too, the difference between the methods was not significant.

A separate assessment on joints, done in only a single study, showed a similar conclusion. Yi et al.3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
demonstrated that fractures of the bones of the shoulder, pelvis, ankle and wrist had a similar detection rate through both low-dose CT and standard-dose CT, in terms of the evaluations on both the number of patients and the number of bones.

Lee et al.1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....
demonstrated good reproducibility among the evaluators, including between those from different specialties (a doctor in the emergency department and a radiologist). All the evaluators analyzed all the CT scans, in terms of both the number of patients and the number of bones. The detection rate for the emergency room physician was 80% in the bone assessments using standard-dose CT whereas with low-dose CT it was 73%. The detection rate for the radiologist was 82% in the bone assessments using standard-dose CT and 76% using low-dose CT. The detection rates in the evaluation according to patients was exactly the same for the two professionals: 97% with both standard-dose CT and low-dose CT.

Mulkens et al.3535. Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
https://doi.org/10.3174/ajnr.A0608...
assessed the quality of the images in low-dose CT compared with the quality in standard-dose CT. In analysis on the images done by different evaluators, it was found that although low-dose CT had lower image quality than standard-dose CT, the examination with low-dose CT preserved sufficient quality for accurate assessment of fractures. This study also demonstrated good reproducibility among the evaluators with regard to diagnosing fractures, as shown by Lee et al.1818. Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
https://doi.org/10.1016/j.clinimag.2018....

Trauma is responsible for 19% of all fractures, and the incidence of these fractures also increases with age. Brazil, for example, leads the world statistics on traffic accidents, which are the predominant cause of trauma in this country.3737. Arruda LRP, de Campos Silva MA, Malerba FG, de Castro Fernandes M, Matsumoto FMTMH. Fraturas expostas: estudo epidemiológico e prospectivo. Acta Ortopédica Brasileira 2009;17:326-30. https://doi. org/10.1590/S1413-78522009000600002.
https://doi.org/10.1590/S1413-7852200900...
,3838. Soares DS, Mello LM, Silva AS, Martinez EZ, Nunes AA. Fraturas de fêmur em idosos no Brasil: análise espaço-temporal de 2008 a 2012 [Femoral fractures in elderly Brazilians: a spatial and temporal analysis from 2008 to 2012]. Cad Saude Publica. 2014;30(12):2669-78. PMID: 26247995; https://doi.org/10.1590/0102-311X00218113.
https://doi.org/10.1590/0102-311X0021811...
Thus, high numbers of fractures occur in Brazil, which requires large numbers of CT scans. Reduction of the radiation dose from CT scans in Brazil is valuable and important because this will diminish costs.

CT accounts for 13% of all radiological examinations in the United States and between 40% and 70% of the radiation that patients receive.3939. Lee CI, Haims AH, Monico EP, Brink JA, Forman HP. Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology. 2004;231(2):393-8. PMID: 15031431; https://doi.org/10.1148/radiol.2312030767.
https://doi.org/10.1148/radiol.231203076...
,4040. Kim PK, Gracias VH, Maidment AD, et al. Cumulative radiation dose caused by radiologic studies in critically ill trauma patients. J Trauma. 2004;57(3):510-4. PMID: 15454795; https://doi.org/10.1097/01. ta.0000141028.97753.67.
https://doi.org/10.1097/01.ta.0000141028...
,4141. Salottolo K, Bar-Or R, Fleishman M, et al. Current utilization and radiation dose from computed tomography in patients with trauma. Crit Care Med. 2009;37(4):1336-40. PMID: 19242327; https://doi.org/10.1097/ CCM.0b013e31819d6739.
https://doi.org/10.1097/CCM.0b013e31819d...
It also needs to be taken into account that CT is responsible for the greatest exposure to radiation among trauma patients, since they frequently undergo CT scans.77. Tien HC, Tremblay LN, Rizoli SB, et al. Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007;62(1):151-6. PMID: 17215747; https://doi.org/10.1097/TA.0b013e31802d9700.
https://doi.org/10.1097/TA.0b013e31802d9...
,99. Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing Radiation Dose in Computed Tomography of Articular Fractures. J Orthop Trauma. 2017;31(8):401-6. PMID: 28394843; https://doi.org/10.1097/ BOT.0000000000000861.
https://doi.org/10.1097/BOT.000000000000...
,1515. Widmann G, Juranek D, Waldenberger F, et al. Influence of Ultra-Low-Dose and Iterative Reconstructions on the Visualization of Orbital Soft Tissues on Maxillofacial CT. AJNR Am J Neuroradiol. 2017;38(8):1630-5. PMID: 28596194; https://doi.org/10.3174/ajnr.A5239.
https://doi.org/10.3174/ajnr.A5239...
,2222. Kocyigit A, Serinken M, Ceven Z, et al. A strategy to optimize CT use in children with mild blunt head trauma utilizing clinical risk stratification; could we improve CT use in children with mild head injury? Clin Imaging. 2014;38(3):236-40. PMID: 24444707; https://doi.org/10.1016/j. clinimag.2013.12.004.
https://doi.org/10.1016/j.clinimag.2013....
,4242. Neubauer J, Benndorf M, Reidelbach C, et al. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists. PLoS One. 2016;11(10):e0164859. PMID: 27788215; https://doi.org/10.1371/journal.pone.0164859.
https://doi.org/10.1371/journal.pone.016...
,4343. Stuhlfaut JW, Lucey BC, Varghese JC, Soto JA. Blunt abdominal trauma: utility of 5-minute delayed CT with a reduced radiation dose. Radiology. 2006;238(2):473-9. PMID: 16436812; https://doi.org/10.1148/ radiol.2382042096.
https://doi.org/10.1148/radiol.238204209...
Although bones are only minimally affected by radiation, the bone marrow is the most radiosensitive organ in the body.3636. Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
https://doi.org/10.1259/bjr.20170240...
Although CT is responsible for 40-70% of patients’ radiation doses,3939. Lee CI, Haims AH, Monico EP, Brink JA, Forman HP. Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology. 2004;231(2):393-8. PMID: 15031431; https://doi.org/10.1148/radiol.2312030767.
https://doi.org/10.1148/radiol.231203076...
,4040. Kim PK, Gracias VH, Maidment AD, et al. Cumulative radiation dose caused by radiologic studies in critically ill trauma patients. J Trauma. 2004;57(3):510-4. PMID: 15454795; https://doi.org/10.1097/01. ta.0000141028.97753.67.
https://doi.org/10.1097/01.ta.0000141028...
,4141. Salottolo K, Bar-Or R, Fleishman M, et al. Current utilization and radiation dose from computed tomography in patients with trauma. Crit Care Med. 2009;37(4):1336-40. PMID: 19242327; https://doi.org/10.1097/ CCM.0b013e31819d6739.
https://doi.org/10.1097/CCM.0b013e31819d...
this percentage goes up to 97.5% in the case of hospitalized patients.1212. Lemburg SP, Peters SA, Roggenland D, Nicolas V, Heyer CM. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries. AJR Am J Roentgenol. 2010;195(6):1411-7. PMID: 21098203; https://doi.org/10.2214/AJR.10.4616.
https://doi.org/10.2214/AJR.10.4616...
In the pediatric population, the effective dose can be up to three times higher than in the adult population.2424. Kim PK, Zhu X, Houseknecht E, et al. Effective radiation dose from radiologic studies in pediatric trauma patients. World J Surg. 2005;29(12):1557-62. PMID: 16331342; https://doi.org/10.1007/s00268-005-0106-x.
https://doi.org/10.1007/s00268-005-0106-...
The risk of developing cancer later in life is more powerfully predicted when effective doses of 5.6 mSv for the lumbar spine and 10.0 mSv for the whole dorsal spine are administered through CT, measured by means of radiography.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...
,1010. Sollmann N, Mei K, Hedderich DM, et al. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures. Eur Radiol. 2019;29(7):3606-16. PMID: 30903337; https://doi.org/10.1007/s00330-019-06090-2.
https://doi.org/10.1007/s00330-019-06090...
,4444. Richards PJ, George J. Diagnostic CT radiation and cancer induction. Skeletal Radiol. 2010;39(5):421-4. PMID: 19953245; https://doi. org/10.1007/s00256-009-0819-2.
https://doi.org/10.1007/s00256-009-0819-...

Given that, so far, no feasible safe dose of ionizing radiation that does not present a risk of cell damage and consequently cancer has been determined,99. Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing Radiation Dose in Computed Tomography of Articular Fractures. J Orthop Trauma. 2017;31(8):401-6. PMID: 28394843; https://doi.org/10.1097/ BOT.0000000000000861.
https://doi.org/10.1097/BOT.000000000000...
there is great interest in reducing radiation levels while maintaining the rate of fracture detection. This is even more so in the pediatric population, given that reducing the doses administered to children reduces the incidence of cancer decades after exposure. In 2007, four million CT scans were performed among children in the United States.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...

CT can be performed with much lower doses of radiation than the standard radiation dose, despite the consequent increase in image noise and reduced image quality.55. Alshamari M, Geijer M, Norrman E, Geijer H. Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality. Acta Radiol. 2014;55(7):824-32. PMID: 24215904; https://doi.org/10.1177/0284185113509615.
https://doi.org/10.1177/0284185113509615...
,4545. Wirth S, Euler E, Linsenmaier U, et al. C-arm-based mobile computed tomography: a comparison with established imaging on the basis of simulated treatments of talus neck fractures in a cadaveric study. Comput Aided Surg. 2004;9(1-2):27-38. PMID: 15792934; https://doi. org/10.3109/10929080400006309.
https://doi.org/10.3109/1092908040000630...
,4646. Kopp FK, Holzapfel K, Baum T, et al. Effect of Low-Dose MDCT and Iterative Reconstruction on Trabecular Bone Microstructure Assessment. PLoS One. 2016;11(7):e0159903. PMID: 27447827; https://doi.org/10.1371/ journal.pone.0159903.
https://doi.org/10.1371/journal.pone.015...
,4747. Lessmann N, van Ginneken B, de Jong PA, Išgum I. Iterative fully convolutional neural networks for automatic vertebra segmentation and identification. Med Image Anal. 2019;53:142-55. PMID: 30771712; https://doi.org/10.1016/j.media.2019.02.005.
https://doi.org/10.1016/j.media.2019.02....
It can even be done using the same radiation dose as in radiography.3030. Alshamari M, Geijer M, Norrman E, et al. Low dose CT of the lumbar spine compared with radiography: a study on image quality with implications for clinical practice. Acta Radiol. 2016;57(5):602-11. PMID: 26221055; https://doi.org/10.1177/0284185115595667.
https://doi.org/10.1177/0284185115595667...
,4848. Hultman KL, Vaidya R, Malkawi I, Carlson JB, Wynberg JB. Accuracy of Low Dose Computed Tomography Scanogram for Measurement of Femoral Version after Locked Intramedullary Nailing. Int Orthop. 2016;40(9):1955-60. PMID: 26572887; https://doi.org/10.1007/s00264-015-3040-z.
https://doi.org/10.1007/s00264-015-3040-...
It seems to be particularly advantageous to indicate a reduced radiation protocol for CT on the extremities, because the area scanned is smaller than that of other regions of the human body, like the abdomen, for example.4949. Pache G, Bulla S, Baumann T, et al. Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique. Acad Radiol. 2012;19(12):1539-45. PMID: 23020888; https://doi.org/10.1016/j.acra.2012.08.006.
https://doi.org/10.1016/j.acra.2012.08.0...

Moreover, it needs to be borne in mind that multislice CT tubes have a production life of around 800,000 slice and their average cost is 30,000 pounds (approximately 41,667.00 US dollars or 227,334.00 reais).5050. Crawley T, Meagher T, Wainwright A. Good practice or good luck? Prolonged CT tube life and low dose protocols. Clin Radiol. 2002;57(5):431. PMID: 12014946; https://doi.org/10.1053/crad.2002.0984.
https://doi.org/10.1053/crad.2002.0984...
If the radiation dose were to be halved, the useful life of the CT tube would be increased fourfold, thereby giving rise to important savings.5050. Crawley T, Meagher T, Wainwright A. Good practice or good luck? Prolonged CT tube life and low dose protocols. Clin Radiol. 2002;57(5):431. PMID: 12014946; https://doi.org/10.1053/crad.2002.0984.
https://doi.org/10.1053/crad.2002.0984...
In this regard, it also needs to be remembered that the number of CT scans performed is constantly increasing, year by year. In the United States, 70 million CT scans were performed in 2014, which was 20 times more than had been documented in 1980.55. Alshamari M, Geijer M, Norrman E, Geijer H. Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality. Acta Radiol. 2014;55(7):824-32. PMID: 24215904; https://doi.org/10.1177/0284185113509615.
https://doi.org/10.1177/0284185113509615...

The following methods can be used to reduce the patient’s radiation dose received through computed tomography:
  • Reducing the milliampere-second setting: if the milliam-pere-second value is reduced by 50%, the radiation dose will be reduced by the same amount.5151. McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics. 2002;22(6):1541-53. PMID: 12432127; https://doi.org/10.1148/rg.226025128.
    https://doi.org/10.1148/rg.226025128...

  • Increasing the pitch: the radiation dose is inversely proportional to the pitch when all other factors are kept constant.5151. McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics. 2002;22(6):1541-53. PMID: 12432127; https://doi.org/10.1148/rg.226025128.
    https://doi.org/10.1148/rg.226025128...

  • Changing the milliamp setting according to the patient’s size: the milliamp-second value can be reduced proportionally with smaller sizes of patients.5151. McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics. 2002;22(6):1541-53. PMID: 12432127; https://doi.org/10.1148/rg.226025128.
    https://doi.org/10.1148/rg.226025128...

  • Reducing the x-ray beam energy (kilovolt peak): reducing the beam energy results in a reduced radiation dose when all other factors are kept constant.5151. McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics. 2002;22(6):1541-53. PMID: 12432127; https://doi.org/10.1148/rg.226025128.
    https://doi.org/10.1148/rg.226025128...

  • Model-based iterative reconstruction: this provides lower image noise and fewer artifacts; it has been designed to complement other dose-reduction methods while preserving diagnostic image quality.5252. Afadzi M, Fosså K, Andersen HK, Aaløkken TM, Martinsen ACT. Image Quality Measured From Ultra-Low Dose Chest Computed Tomography Examination Protocols Using 6 Different Iterative Reconstructions From 4 Vendors, a Phantom Study. J Comput Assist Tomogr. 2020;44(1):95-101. PMID: 31939889; https://doi.org/10.1097/ RCT.0000000000000947.
    https://doi.org/10.1097/RCT.000000000000...

  • Deep learning: this can distinguish noise from signal in CT images and, consequently, can boost signal while diminishing noise.5353. Singh R, Digumarthy SR, Muse VV, et al. Image Quality and Lesion Detection on Deep Learning Reconstruction and Iterative Reconstruction of Submillisievert Chest and Abdominal CT. AJR Am J Roentgenol. 2020;214(3):566-73. PMID: 31967501; https://doi. org/10.2214/AJR.19.21809.
    https://doi.org/10.2214/AJR.19.21809...

  • Machine-learning algorithms, as a subfield of artificial intelligence: different types of machine learning (linear regression, regression trees, bagged regression trees, Gaussian process regression, support vector machine (SVM) regression or neural networks) can reduce the radiation dosage, to adapt to new circumstances and identify and rate standards.44. Garcia-Sanchez AJ, Garcia Angosto E, Llor JL, Serna Berna A, Ramos D. Machine Learning Techniques Applied to Dose Prediction in Computed Tomography Tests. Sensors (Basel). 2019;19(23):5116. PMID: 31766708; https://doi.org/10.3390/s19235116.
    https://doi.org/10.3390/s19235116...

Within the scope of public health interest, the importance of reduction of this radiation dose is in relation to the following:
  • Reduction of long-term incidence of malignancies.

  • Reduced spending on high-cost medications and procedures for malignant neoplasms, i.e. chemotherapy, radiotherapy, surgery, hospitalization, etc.

  • Increasing the population’s quality of life.

  • Reduced expenditure on CT tubes.

These changes would give rise to significant savings. They would enable reallocation of funds to areas that need more attention. Thus, this is a matter of enormous administrative relevance since, in addition to the savings already mentioned, new investments would cease to be necessary (exchange of devices, purchase of software and relocation of devices), given that only adjustments to the regulation of CT examination protocols are needed.5151. McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics. 2002;22(6):1541-53. PMID: 12432127; https://doi.org/10.1148/rg.226025128.
https://doi.org/10.1148/rg.226025128...

In addition, in cases of patients with diseases that require CT monitoring, low-dose CT scans provide the possibility of shorter time intervals between examinations, thus making it possible to adjust the treatment when necessary and, hence, making it possible to avoid worsening of the disease.5454. Mookiah MRK, Baum T, Mei K, et al. Effect of radiation dose reduction on texture measures of trabecular bone microstructure: an in vitro study. J Bone Miner Metab. 2018;36(3):323-35. PMID: 28389933; https://doi. org/10.1007/s00774-017-0836-5.
https://doi.org/10.1007/s00774-017-0836-...

The present findings have some implications for future research. Low-dose CT was shown here to maintain the bone fracture detection rate and was previously shown to be effective for evaluation of pulmonary nodules5555. Ruchalski K, Gutierrez A, Genshaft S, Abtin F, Suh R. The evidence for low-dose CT screening of lung cancer. Clin Imaging. 2016;40(2):288-95. PMID: 26362352; https://doi.org/10.1016/j.clinimag.2015.07.001.
https://doi.org/10.1016/j.clinimag.2015....
,5656. Raymakers AJN, Mayo J, Lam S, et al. Cost-Effectiveness Analyses of Lung Cancer Screening Strategies Using Low-Dose Computed Tomography: a Systematic Review. Appl Health Econ Health Policy. 2016;14(4):409-18. PMID: 26873091; https://doi.org/10.1007/s40258-016-0226-5.
https://doi.org/10.1007/s40258-016-0226-...
and lithiasis in the urinary tract.5757. Rob S, Bryant T, Wilson I, Somani BK. Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature. Clin Radiol. 2017;72(1):11-5. PMID: 27810168; https://doi.org/10.1016/j. crad.2016.10.005.
https://doi.org/10.1016/j.crad.2016.10.0...
In the latter, moreover, ultra-low-dose CT is already being used.5757. Rob S, Bryant T, Wilson I, Somani BK. Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature. Clin Radiol. 2017;72(1):11-5. PMID: 27810168; https://doi.org/10.1016/j. crad.2016.10.005.
https://doi.org/10.1016/j.crad.2016.10.0...
,5858. Sui X, Meinel FG, Song W, et al. Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT. Eur J Radiol. 2016;85(3):564-70. PMID: 26860668; https://doi.org/10.1016/j.ejrad.2015.12.013.
https://doi.org/10.1016/j.ejrad.2015.12....
Therefore, low-dose CT should begin to be evaluated for assessment of other structures, such as the appendix, pancreas and sinuses, among others.

Even with the advent of MRI, CT remains the gold standard for diagnosing bone fractures.2525. Duane TM, Mayglothling J, Wilson SP, et al. National Emergency X-Radiography Utilization Study criteria is inadequate to rule out fracture after significant blunt trauma compared with computed tomography. J Trauma. 2011;70(4):829-31. PMID: 21610391; https://doi.org/10.1097/ TA.0b013e31820ea6b3.
https://doi.org/10.1097/TA.0b013e31820ea...
,2626. Haapamäki VV, Kiuru MJ, Mustonen AO, Koskinen SK. Multidetector computed tomography in acute joint fractures. Acta Radiol. 2005;46(6):587-98. PMID: 16334840; https://doi.org/10.1080/02841850510021634.
https://doi.org/10.1080/0284185051002163...
,2727. Konda SR, Goch AM, Haglin J, Egol KA. Ultralow-Dose CT (REDUCTION Protocol) for Extremity Fracture Evaluation Is as Safe and Effective as Conventional CT: An Evaluation of Quality Outcomes. J Orthop Trauma. 2018;32(5):216-222. PMID: 29401094; https://doi.org/10.1097/ BOT.0000000000001137.
https://doi.org/10.1097/BOT.000000000000...
Therefore, regarding evaluation of bone fractures, we believe that further studies are needed to assess the use of ultra-low-dose CT, which so far has only been analyzed by Konda et al.2828. Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using CT in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668-73. PMID: 27909130; https://doi.org/10.1302/0301-620X.98B12.BJJ-2016-0336.R1.
https://doi.org/10.1302/0301-620X.98B12....

Ultra-low-dose CT uses a radiation dose similar to that of radiography and, consequently, further reduces the incidence of malignant neoplasms caused by standard-dose CT. Today, standard-dose CT is the cause of 1.5-2% of cases of malignant neo-plasms.11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...
,66. Banerjee P, Thomas M. CT scans to exclude spine fractures in children after negative radiographs may lead to increase in future cancer risk. Eur J Orthop Surg Traumatol. 2019;29(5):983-8. PMID: 30941632; https:// doi.org/10.1007/s00590-019-02396-5.
https://doi.org/10.1007/s00590-019-02396...
This proportion is higher among children under 15 years old,11. Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
https://doi.org/10.1056/NEJMra072149...
,1212. Lemburg SP, Peters SA, Roggenland D, Nicolas V, Heyer CM. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries. AJR Am J Roentgenol. 2010;195(6):1411-7. PMID: 21098203; https://doi.org/10.2214/AJR.10.4616.
https://doi.org/10.2214/AJR.10.4616...
,2828. Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using CT in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668-73. PMID: 27909130; https://doi.org/10.1302/0301-620X.98B12.BJJ-2016-0336.R1.
https://doi.org/10.1302/0301-620X.98B12....
and even more so among children younger than 5 years.66. Banerjee P, Thomas M. CT scans to exclude spine fractures in children after negative radiographs may lead to increase in future cancer risk. Eur J Orthop Surg Traumatol. 2019;29(5):983-8. PMID: 30941632; https:// doi.org/10.1007/s00590-019-02396-5.
https://doi.org/10.1007/s00590-019-02396...
Moreover, use of ultra-low-dose CT implies lower spending on medications and CT tubes. It would lead to increased quality of life for this population, over the long term.

However, as quoted by Lee,1919. Lee RK, Chu WC, Graham CA, Rainer TH, Ahuja AT. Knowledge of radiation exposure in common radiological investigations: a comparison between radiologists and non-radiologists. Emerg Med J. 2012;29(4):306-8. PMID: 21873321; https://doi.org/10.1136/emermed-2011-200481.
https://doi.org/10.1136/emermed-2011-200...
,3939. Lee CI, Haims AH, Monico EP, Brink JA, Forman HP. Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology. 2004;231(2):393-8. PMID: 15031431; https://doi.org/10.1148/radiol.2312030767.
https://doi.org/10.1148/radiol.231203076...
only 9%-16% of doctors are aware of the risk of malignant neoplasms caused by radiation. Furthermore, 75% of radiologists and on-call staff in emergency departments underestimate the radiation dose of CT, and 91% of emergency room doctors do not know that CT increases the risk of cancer throughout life. Added to this is the fact that more than 90% of patients are not informed about the dangers of radiation before they undergo CT.1919. Lee RK, Chu WC, Graham CA, Rainer TH, Ahuja AT. Knowledge of radiation exposure in common radiological investigations: a comparison between radiologists and non-radiologists. Emerg Med J. 2012;29(4):306-8. PMID: 21873321; https://doi.org/10.1136/emermed-2011-200481.
https://doi.org/10.1136/emermed-2011-200...
,3939. Lee CI, Haims AH, Monico EP, Brink JA, Forman HP. Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology. 2004;231(2):393-8. PMID: 15031431; https://doi.org/10.1148/radiol.2312030767.
https://doi.org/10.1148/radiol.231203076...
Therefore, it is extremely necessary to inform both healthcare professionals and patients about the risks of radiation and the ways in which its use in CT can be improved.

CONCLUSION

According to the results from this systematic review and meta-analysis, it can be suggested that, in evaluating trauma victims (cases due to falls, traffic accidents, etc.) and for patients undergoing tomographic monitoring of fractures, low-dose CT should be used within clinical practice. This will reduce the radiation dose delivered to patients while maintaining the rate of fracture detection, in addition to reducing costs. Through this, it will be possible to maintain the quality of fracture diagnosis, while still avoiding complications of misdiagnosis, such as chronic arthritis, painful non-union or osteonecrosis. A decrease in CT radiation exposure is required, but image quality needs to be maintained for diagnostic accuracy.

It should be taken into account that, in our review, studies using multislice computed tomography devices with between 6 and 320 channels were evaluated, as there were no studies on other devices (helical or multislice with fewer channels) of sufficient quality for their inclusion. Evaluation of low-dose CT in patients with metallic structures was not possible since all the studies examined had excluded patients presenting metallic components (nails, screws, prostheses, etc.), from their selection of patients.

Acknowledgements:

To Ms. Roberta Neves Gago Rodrigues for the translation adjustments and spelling correction

REFERENCES

  • 1
    Brenner DJ, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-84. PMID: 18046031; https://doi.org/10.1056/NEJMra072149.
    » https://doi.org/10.1056/NEJMra072149
  • 2
    Brisco J, Fuller K, Lee N, Andrew D. Cone beam computed tomography for imaging orbital trauma--image quality and radiation dose compared with conventional multislice computed tomography. Br J Oral Maxillofac Surg. 2014;52(1):76-80. PMID: 24139635; https://doi.org/10.1016/j. bjoms.2013.09.011.
    » https://doi.org/10.1016/j.bjoms.2013.09.011
  • 3
    Kloth JK, Rickert M, Gotterbarm T, et al. Pelvic X-ray examinations in follow-up of hip arthroplasty or femoral osteosynthesis--dose reduction and quality criteria. Eur J Radiol. 2015;84:915-20. PMID: 25715664; https://doi.org/10.1016/j.ejrad.2015.02.001.
    » https://doi.org/10.1016/j.ejrad.2015.02.001
  • 4
    Garcia-Sanchez AJ, Garcia Angosto E, Llor JL, Serna Berna A, Ramos D. Machine Learning Techniques Applied to Dose Prediction in Computed Tomography Tests. Sensors (Basel). 2019;19(23):5116. PMID: 31766708; https://doi.org/10.3390/s19235116.
    » https://doi.org/10.3390/s19235116
  • 5
    Alshamari M, Geijer M, Norrman E, Geijer H. Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality. Acta Radiol. 2014;55(7):824-32. PMID: 24215904; https://doi.org/10.1177/0284185113509615.
    » https://doi.org/10.1177/0284185113509615
  • 6
    Banerjee P, Thomas M. CT scans to exclude spine fractures in children after negative radiographs may lead to increase in future cancer risk. Eur J Orthop Surg Traumatol. 2019;29(5):983-8. PMID: 30941632; https:// doi.org/10.1007/s00590-019-02396-5.
    » https://doi.org/10.1007/s00590-019-02396-5
  • 7
    Tien HC, Tremblay LN, Rizoli SB, et al. Radiation exposure from diagnostic imaging in severely injured trauma patients. J Trauma. 2007;62(1):151-6. PMID: 17215747; https://doi.org/10.1097/TA.0b013e31802d9700.
    » https://doi.org/10.1097/TA.0b013e31802d9700
  • 8
    Moritz JD, Hoffmann B, Sehr D, et al. Evaluation of ultra-low dose CT in the diagnosis of pediatric-like fractures using an experimental animal study. Korean J Radiol. 2012;13(2):165-73. PMID: 22438683; https://doi. org/10.3348/kjr.2012.13.2.165.
    » https://doi.org/10.3348/kjr.2012.13.2.165
  • 9
    Mansfield C, Ali S, Komperda K, Zhao H, Rehman S. Optimizing Radiation Dose in Computed Tomography of Articular Fractures. J Orthop Trauma. 2017;31(8):401-6. PMID: 28394843; https://doi.org/10.1097/ BOT.0000000000000861.
    » https://doi.org/10.1097/BOT.0000000000000861
  • 10
    Sollmann N, Mei K, Hedderich DM, et al. Multi-detector CT imaging: impact of virtual tube current reduction and sparse sampling on detection of vertebral fractures. Eur Radiol. 2019;29(7):3606-16. PMID: 30903337; https://doi.org/10.1007/s00330-019-06090-2.
    » https://doi.org/10.1007/s00330-019-06090-2
  • 11
    Kim SJ, Bista AB, Min YG, et al. Usefulness of low dose chest CT for initial evaluation of blunt chest trauma [published correction appears in Medicine (Baltimore). 2017;96(23):e7234]. Medicine (Baltimore). 2017;96(2):e5888. PMID: 28079832; https://doi.org/10.1097/ MD.0000000000005888.
    » https://doi.org/10.1097/MD.0000000000005888
  • 12
    Lemburg SP, Peters SA, Roggenland D, Nicolas V, Heyer CM. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries. AJR Am J Roentgenol. 2010;195(6):1411-7. PMID: 21098203; https://doi.org/10.2214/AJR.10.4616.
    » https://doi.org/10.2214/AJR.10.4616
  • 13
    Rozema R, Doff MH, van Ooijen PM, et al. Diagnostic reliability of low dose multidetector CT and cone beam CT in maxillofacial trauma-an experimental blinded and randomized study. Dentomaxillofac Radiol. 2018;47(8):20170423. PMID: 29745761; https://doi.org/10.1259/ dmfr.20170423.
    » https://doi.org/10.1259/dmfr.20170423
  • 14
    Ippolito D, Besostri V, Bonaffini PA, et al. Diagnostic value of whole-body low-dose computed tomography (WBLDCT) in bone lesions detection in patients with multiple myeloma (MM). Eur J Radiol. 2013;82(12):2322-7. PMID: 24074647; https://doi.org/10.1016/j.ejrad.2013.08.036.
    » https://doi.org/10.1016/j.ejrad.2013.08.036
  • 15
    Widmann G, Juranek D, Waldenberger F, et al. Influence of Ultra-Low-Dose and Iterative Reconstructions on the Visualization of Orbital Soft Tissues on Maxillofacial CT. AJNR Am J Neuroradiol. 2017;38(8):1630-5. PMID: 28596194; https://doi.org/10.3174/ajnr.A5239.
    » https://doi.org/10.3174/ajnr.A5239
  • 16
    Jin L, Ge X, Lu F, et al. Low-dose CT examination for rib fracture evaluation: A pilot study. Medicine (Baltimore). 2018;97(30):e11624. PMID: 30045304; https://doi.org/10.1097/MD.0000000000011624.
    » https://doi.org/10.1097/MD.0000000000011624
  • 17
    Lee SH, Yun SJ, Kim DH, et al. Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT. Br J Radiol. 2017;90(1077):20170181. PMID: 28707527; https://doi.org/10.1259/bjr.20170181.
    » https://doi.org/10.1259/bjr.20170181
  • 18
    Lee SH, Yun SJ, Jo HH, Song JG. Diagnosis of lumbar spinal fractures in emergency department: low-dose versus standard-dose CT using model-based iterative reconstruction. Clin Imaging. 2018;50:216-22. PMID: 29677654; https://doi.org/10.1016/j.clinimag.2018.04.007.
    » https://doi.org/10.1016/j.clinimag.2018.04.007
  • 19
    Lee RK, Chu WC, Graham CA, Rainer TH, Ahuja AT. Knowledge of radiation exposure in common radiological investigations: a comparison between radiologists and non-radiologists. Emerg Med J. 2012;29(4):306-8. PMID: 21873321; https://doi.org/10.1136/emermed-2011-200481.
    » https://doi.org/10.1136/emermed-2011-200481
  • 20
    Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380(9840):499-505. PMID: 22681860; https://doi.org/10.1016/S0140-6736(12)60815-0.
    » https://doi.org/10.1016/S0140-6736(12)60815-0
  • 21
    Andresz S, Morgan J, Croüail P, Vermeersch F. Conclusions and recommendations from the 17th Workshop of the European ALARA Network ‘ALARA in emergency exposure situations’. J Radiol Prot. 2018;38(1):434-9. PMID: 29339579; https://doi.org/10.1088/1361-6498/aaa86b.
    » https://doi.org/10.1088/1361-6498/aaa86b
  • 22
    Kocyigit A, Serinken M, Ceven Z, et al. A strategy to optimize CT use in children with mild blunt head trauma utilizing clinical risk stratification; could we improve CT use in children with mild head injury? Clin Imaging. 2014;38(3):236-40. PMID: 24444707; https://doi.org/10.1016/j. clinimag.2013.12.004.
    » https://doi.org/10.1016/j.clinimag.2013.12.004
  • 23
    Kahn J, Kaul D, Böning G, et al. Quality and Dose Optimized CT Trauma Protocol - Recommendation from a University Level-I Trauma Center. Qualitäts- und dosisoptimiertes CT-Polytraumaprotokoll – Empfehlung eines universitären Level-I Traumazentrums. Rofo. 2017;189(9):844-54. PMID: 28651263; https://doi.org/10.1055/s-0043-108996.
    » https://doi.org/10.1055/s-0043-108996
  • 24
    Kim PK, Zhu X, Houseknecht E, et al. Effective radiation dose from radiologic studies in pediatric trauma patients. World J Surg. 2005;29(12):1557-62. PMID: 16331342; https://doi.org/10.1007/s00268-005-0106-x.
    » https://doi.org/10.1007/s00268-005-0106-x
  • 25
    Duane TM, Mayglothling J, Wilson SP, et al. National Emergency X-Radiography Utilization Study criteria is inadequate to rule out fracture after significant blunt trauma compared with computed tomography. J Trauma. 2011;70(4):829-31. PMID: 21610391; https://doi.org/10.1097/ TA.0b013e31820ea6b3.
    » https://doi.org/10.1097/TA.0b013e31820ea6b3
  • 26
    Haapamäki VV, Kiuru MJ, Mustonen AO, Koskinen SK. Multidetector computed tomography in acute joint fractures. Acta Radiol. 2005;46(6):587-98. PMID: 16334840; https://doi.org/10.1080/02841850510021634.
    » https://doi.org/10.1080/02841850510021634
  • 27
    Konda SR, Goch AM, Haglin J, Egol KA. Ultralow-Dose CT (REDUCTION Protocol) for Extremity Fracture Evaluation Is as Safe and Effective as Conventional CT: An Evaluation of Quality Outcomes. J Orthop Trauma. 2018;32(5):216-222. PMID: 29401094; https://doi.org/10.1097/ BOT.0000000000001137.
    » https://doi.org/10.1097/BOT.0000000000001137
  • 28
    Konda SR, Goch AM, Leucht P, et al. The use of ultra-low-dose CT scans for the evaluation of limb fractures: is the reduced effective dose using CT in orthopaedic injury (REDUCTION) protocol effective? Bone Joint J. 2016;98-B(12):1668-73. PMID: 27909130; https://doi.org/10.1302/0301-620X.98B12.BJJ-2016-0336.R1.
    » https://doi.org/10.1302/0301-620X.98B12.BJJ-2016-0336.R1
  • 29
    Zacchino M, Bonaffini PA, Corso A, et al. Inter-observer agreement for the evaluation of bone involvement on Whole Body Low Dose Computed Tomography (WBLDCT) in Multiple Myeloma (MM). Eur Radiol. 2015;25(11):3382-9. PMID: 25987427; https://doi.org/10.1007/ s00330-015-3733-0.
    » https://doi.org/10.1007/s00330-015-3733-0
  • 30
    Alshamari M, Geijer M, Norrman E, et al. Low dose CT of the lumbar spine compared with radiography: a study on image quality with implications for clinical practice. Acta Radiol. 2016;57(5):602-11. PMID: 26221055; https://doi.org/10.1177/0284185115595667.
    » https://doi.org/10.1177/0284185115595667
  • 31
    Finkenstaedt T, Morsbach F, Calcagni M, et al. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography. Invest Radiol. 2014;49(8):532-9. PMID: 24691141; https://doi.org/10.1097/ RLI.0000000000000052.
    » https://doi.org/10.1097/RLI.0000000000000052
  • 32
    Whiting PF, Rutjes AW, Westwood ME, et al. QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med. 2011;155(8):529-536. PMID: 22007046; https://doi.org/10.7326/0003-4819-155-8-201110180-00009.
    » https://doi.org/10.7326/0003-4819-155-8-201110180-00009
  • 33
    Margulis AV, Pladevall M, Riera-Guardia N, et al. Quality assessment of observational studies in a drug-safety systematic review, comparison of two tools: the Newcastle-Ottawa Scale and the RTI item bank. Clin Epidemiol. 2014;6:359-68. PMID: 25336990; https://doi.org/10.2147/CLEP.S66677.
    » https://doi.org/10.2147/CLEP.S66677
  • 34
    Viswanathan M, Berkman ND. Development of the RTI item bank on risk of bias and precision of observational studies. J Clin Epidemiol. 2012;65(2):163-78. PMID: 21959223; https://doi.org/10.1016/j. jclinepi.2011.05.008.
    » https://doi.org/10.1016/j.jclinepi.2011.05.008
  • 35
    Mulkens TH, Marchal P, Daineffe S, et al. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28(8):1444-50. PMID: 17846188; https://doi. org/10.3174/ajnr.A0608.
    » https://doi.org/10.3174/ajnr.A0608
  • 36
    Yi JW, Park HJ, Lee SY, et al. Radiation dose reduction in multidetector CT in fracture evaluation. Br J Radiol. 2017;90(1077):20170240. PMID: 28707536; https://doi.org/10.1259/bjr.20170240.
    » https://doi.org/10.1259/bjr.20170240
  • 37
    Arruda LRP, de Campos Silva MA, Malerba FG, de Castro Fernandes M, Matsumoto FMTMH. Fraturas expostas: estudo epidemiológico e prospectivo. Acta Ortopédica Brasileira 2009;17:326-30. https://doi. org/10.1590/S1413-78522009000600002.
    » https://doi.org/10.1590/S1413-78522009000600002
  • 38
    Soares DS, Mello LM, Silva AS, Martinez EZ, Nunes AA. Fraturas de fêmur em idosos no Brasil: análise espaço-temporal de 2008 a 2012 [Femoral fractures in elderly Brazilians: a spatial and temporal analysis from 2008 to 2012]. Cad Saude Publica. 2014;30(12):2669-78. PMID: 26247995; https://doi.org/10.1590/0102-311X00218113.
    » https://doi.org/10.1590/0102-311X00218113
  • 39
    Lee CI, Haims AH, Monico EP, Brink JA, Forman HP. Diagnostic CT scans: assessment of patient, physician, and radiologist awareness of radiation dose and possible risks. Radiology. 2004;231(2):393-8. PMID: 15031431; https://doi.org/10.1148/radiol.2312030767.
    » https://doi.org/10.1148/radiol.2312030767
  • 40
    Kim PK, Gracias VH, Maidment AD, et al. Cumulative radiation dose caused by radiologic studies in critically ill trauma patients. J Trauma. 2004;57(3):510-4. PMID: 15454795; https://doi.org/10.1097/01. ta.0000141028.97753.67.
    » https://doi.org/10.1097/01.ta.0000141028.97753.67
  • 41
    Salottolo K, Bar-Or R, Fleishman M, et al. Current utilization and radiation dose from computed tomography in patients with trauma. Crit Care Med. 2009;37(4):1336-40. PMID: 19242327; https://doi.org/10.1097/ CCM.0b013e31819d6739.
    » https://doi.org/10.1097/CCM.0b013e31819d6739
  • 42
    Neubauer J, Benndorf M, Reidelbach C, et al. Comparison of Diagnostic Accuracy of Radiation Dose-Equivalent Radiography, Multidetector Computed Tomography and Cone Beam Computed Tomography for Fractures of Adult Cadaveric Wrists. PLoS One. 2016;11(10):e0164859. PMID: 27788215; https://doi.org/10.1371/journal.pone.0164859.
    » https://doi.org/10.1371/journal.pone.0164859
  • 43
    Stuhlfaut JW, Lucey BC, Varghese JC, Soto JA. Blunt abdominal trauma: utility of 5-minute delayed CT with a reduced radiation dose. Radiology. 2006;238(2):473-9. PMID: 16436812; https://doi.org/10.1148/ radiol.2382042096.
    » https://doi.org/10.1148/radiol.2382042096
  • 44
    Richards PJ, George J. Diagnostic CT radiation and cancer induction. Skeletal Radiol. 2010;39(5):421-4. PMID: 19953245; https://doi. org/10.1007/s00256-009-0819-2.
    » https://doi.org/10.1007/s00256-009-0819-2
  • 45
    Wirth S, Euler E, Linsenmaier U, et al. C-arm-based mobile computed tomography: a comparison with established imaging on the basis of simulated treatments of talus neck fractures in a cadaveric study. Comput Aided Surg. 2004;9(1-2):27-38. PMID: 15792934; https://doi. org/10.3109/10929080400006309.
    » https://doi.org/10.3109/10929080400006309
  • 46
    Kopp FK, Holzapfel K, Baum T, et al. Effect of Low-Dose MDCT and Iterative Reconstruction on Trabecular Bone Microstructure Assessment. PLoS One. 2016;11(7):e0159903. PMID: 27447827; https://doi.org/10.1371/ journal.pone.0159903.
    » https://doi.org/10.1371/journal.pone.0159903
  • 47
    Lessmann N, van Ginneken B, de Jong PA, Išgum I. Iterative fully convolutional neural networks for automatic vertebra segmentation and identification. Med Image Anal. 2019;53:142-55. PMID: 30771712; https://doi.org/10.1016/j.media.2019.02.005.
    » https://doi.org/10.1016/j.media.2019.02.005
  • 48
    Hultman KL, Vaidya R, Malkawi I, Carlson JB, Wynberg JB. Accuracy of Low Dose Computed Tomography Scanogram for Measurement of Femoral Version after Locked Intramedullary Nailing. Int Orthop. 2016;40(9):1955-60. PMID: 26572887; https://doi.org/10.1007/s00264-015-3040-z.
    » https://doi.org/10.1007/s00264-015-3040-z
  • 49
    Pache G, Bulla S, Baumann T, et al. Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique. Acad Radiol. 2012;19(12):1539-45. PMID: 23020888; https://doi.org/10.1016/j.acra.2012.08.006.
    » https://doi.org/10.1016/j.acra.2012.08.006
  • 50
    Crawley T, Meagher T, Wainwright A. Good practice or good luck? Prolonged CT tube life and low dose protocols. Clin Radiol. 2002;57(5):431. PMID: 12014946; https://doi.org/10.1053/crad.2002.0984.
    » https://doi.org/10.1053/crad.2002.0984
  • 51
    McNitt-Gray MF. AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. Radiographics. 2002;22(6):1541-53. PMID: 12432127; https://doi.org/10.1148/rg.226025128.
    » https://doi.org/10.1148/rg.226025128
  • 52
    Afadzi M, Fosså K, Andersen HK, Aaløkken TM, Martinsen ACT. Image Quality Measured From Ultra-Low Dose Chest Computed Tomography Examination Protocols Using 6 Different Iterative Reconstructions From 4 Vendors, a Phantom Study. J Comput Assist Tomogr. 2020;44(1):95-101. PMID: 31939889; https://doi.org/10.1097/ RCT.0000000000000947.
    » https://doi.org/10.1097/RCT.0000000000000947
  • 53
    Singh R, Digumarthy SR, Muse VV, et al. Image Quality and Lesion Detection on Deep Learning Reconstruction and Iterative Reconstruction of Submillisievert Chest and Abdominal CT. AJR Am J Roentgenol. 2020;214(3):566-73. PMID: 31967501; https://doi. org/10.2214/AJR.19.21809.
    » https://doi.org/10.2214/AJR.19.21809
  • 54
    Mookiah MRK, Baum T, Mei K, et al. Effect of radiation dose reduction on texture measures of trabecular bone microstructure: an in vitro study. J Bone Miner Metab. 2018;36(3):323-35. PMID: 28389933; https://doi. org/10.1007/s00774-017-0836-5.
    » https://doi.org/10.1007/s00774-017-0836-5
  • 55
    Ruchalski K, Gutierrez A, Genshaft S, Abtin F, Suh R. The evidence for low-dose CT screening of lung cancer. Clin Imaging. 2016;40(2):288-95. PMID: 26362352; https://doi.org/10.1016/j.clinimag.2015.07.001.
    » https://doi.org/10.1016/j.clinimag.2015.07.001
  • 56
    Raymakers AJN, Mayo J, Lam S, et al. Cost-Effectiveness Analyses of Lung Cancer Screening Strategies Using Low-Dose Computed Tomography: a Systematic Review. Appl Health Econ Health Policy. 2016;14(4):409-18. PMID: 26873091; https://doi.org/10.1007/s40258-016-0226-5.
    » https://doi.org/10.1007/s40258-016-0226-5
  • 57
    Rob S, Bryant T, Wilson I, Somani BK. Ultra-low-dose, low-dose, and standard-dose CT of the kidney, ureters, and bladder: is there a difference? Results from a systematic review of the literature. Clin Radiol. 2017;72(1):11-5. PMID: 27810168; https://doi.org/10.1016/j. crad.2016.10.005.
    » https://doi.org/10.1016/j.crad.2016.10.005
  • 58
    Sui X, Meinel FG, Song W, et al. Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose CT. Eur J Radiol. 2016;85(3):564-70. PMID: 26860668; https://doi.org/10.1016/j.ejrad.2015.12.013.
    » https://doi.org/10.1016/j.ejrad.2015.12.013
  • 1
    Evidence-Based Health Department and Neurology Department, Universidade Federal de São Paulo (UNIFESP), São Paulo (SP), Brazil
  • Sources of funding: No funding was received for this study

Publication Dates

  • Publication in this collection
    14 June 2021
  • Date of issue
    Jul-Aug 2021

History

  • Received
    07 July 2020
  • Reviewed
    14 Feb 2021
  • Accepted
    19 Feb 2021
Associação Paulista de Medicina - APM APM / Publicações Científicas, Av. Brigadeiro Luís Antonio, 278 - 7º and., 01318-901 São Paulo SP - Brazil, Tel.: +55 11 3188-4310 / 3188-4311, Fax: +55 11 3188-4255 - São Paulo - SP - Brazil
E-mail: revistas@apm.org.br