Acessibilidade / Reportar erro

Determination of plasma temperature by a semi-empirical method

Abstract

Doppler or Stark line broadening effects are generally used to determinate plasma temperature. These methods are difficult to apply to spectra of highly ionized atoms due to the short wavelengths involved. It is not at all easy to achieve sufficient wavelength resolution in this spectral range. In this case, a spectroscopic technique based on the relative intensities of lines must be used to measure the electron temperature in a plasma. However the relation of the measure of relative line intensity and the plasma electron temperature is complex and a number of issues must be examined for the diagnostic. In simple cases, only a two levels system need be considered. Here we introduce a semi-empirical method to determine the plasma temperature that takes into account multiple levels structure. In the theoretical model we consider a local thermodynamic equilibrium(LTE). The greatest difficult in the determination of plasma temperature using a multiple levels approach is overcome by calculating the transition probabilities in terms of the oscillator strength parameters. To check the method we calculated the oscillator strengths for the Cu I using a multi-configurational Hartree-Fock relativistic (HFR) approach. The electrostatic parameters were optimized by a least-squares procedure, in order to obtain the best fitting to the experimental energy levels. This method produces gf- values that are in better agreement with their experimental values than the produced by the ab initio calculation. The temperature obtained was 5739.3 K, what is compatible with direct measurements made for cupper DC discharge.


Determination of plasma temperature by a semi-empirical method

F. O. Borges; G. H. Cavalcanti; A. G. Trigueiros

Laboratório de Plasma e Espectroscopia, Instituto de Física, Universidade Federal Fluminense, UFF Campus da Praia Vermelha-Gragoatá, 24210-340 Niterói, Rio de Janeiro, Brazil

ABSTRACT

Doppler or Stark line broadening effects are generally used to determinate plasma temperature. These methods are difficult to apply to spectra of highly ionized atoms due to the short wavelengths involved. It is not at all easy to achieve sufficient wavelength resolution in this spectral range. In this case, a spectroscopic technique based on the relative intensities of lines must be used to measure the electron temperature in a plasma. However the relation of the measure of relative line intensity and the plasma electron temperature is complex and a number of issues must be examined for the diagnostic. In simple cases, only a two levels system need be considered. Here we introduce a semi-empirical method to determine the plasma temperature that takes into account multiple levels structure. In the theoretical model we consider a local thermodynamic equilibrium(LTE). The greatest difficult in the determination of plasma temperature using a multiple levels approach is overcome by calculating the transition probabilities in terms of the oscillator strength parameters. To check the method we calculated the oscillator strengths for the Cu I using a multi-configurational Hartree-Fock relativistic (HFR) approach. The electrostatic parameters were optimized by a least-squares procedure, in order to obtain the best fitting to the experimental energy levels. This method produces gf- values that are in better agreement with their experimental values than the produced by the ab initio calculation. The temperature obtained was 5739.3 K, what is compatible with direct measurements made for cupper DC discharge.

1 Determination of plasma temperature

The plasma temperature may be estimated through the relative emission intensities of spectral lines. From the theory of atomic structure and spectra [1], the relative intensities of the spectral lines, considering a Boltzmann distribution, are given by the equation

where I, l and f are the relative intensity, wavelength, and oscillator strength respectively. Eu is the energy of the upper level and g is the statistic weight of the lower level; kB is the Boltzmann constant, T is the temperature and b a constant parameter for all ion lines considered. In a few cases, g, f and Eu can be obtained from the handbook of the spectroscopic constants, chemistry and physics.

The equation(1) gives the plasma temperature in the case of LTE approximation. To increase the precision a large number of spectral lines must be used to determine plasma temperature. For a given spectrum, a plot of the logarithmic term in the right hand of equation(1) versus Eu yields a straight line whose slope is equal to 1/kBT. Thus we can obtain the plasma temperature from the slope a. Using

We apply the above mentioned method to some copper lines which spectroscopic constants are listed in Table 2. The major difficult here, is to obtain the oscillator strengths for the observed lines which are absent in the literature. Therefore to obtain the plasma temperature and overcome this diffcult it is necessary to obtain this data in a semi-empirical way.

2 Semi-empirical gf calculation

The oscillator strength f(gg¢) is a physical quantity related to line intensity I and transition probability W(gg¢). According to Sobelman [2] it may be writen as:

where m is the electron mass, e is the electron charge, g is the initial quantum state, w = (E(g)-E(g¢))/, E(g) is the energy of initial state, g = (2J +1) is the number of degenerate quantum states with angular momentum J (in the formula for the initial state). Quantities with primes refer to the final state. The intensity proportionality may be expressed as:

In the equation above, the weighted oscillator strength, gf, is given by Cowan [3] as:

where s = |E(g) - E(g¢)| /hc, h is the Planck's constant, c is the light velocity, and a0 is the Bohr radius, and the electric dipole line strength is defined by:

This quantity is a measure of the total strength of the spectral line, including all the possible transitions between m, m' different Jz eigenstates. The tensor operator P1 (first order) in the reduced matrix element is the classical dipole moment for the atom in units of ea0.

To obtain gf we need to calculate S first or its square root through:

In a multi-configurational calculation it is necessary to expand the wavefunction ½ gJ > in terms of single configuration wavefunctions, ½ bJ > , for both upper and lower levels. The wavefunctions may be expressed as:

Therefore the multiconfigurational expression for in this case is

The probability per unit time of an atom in a specific state ½ gJ > to make a spontaneous transition to any state with lower energy is

where A(gJ, g¢J¢) is the Einstein spontaneous emission transition probability rate for a transition from the ½ gJ> to the ½ g¢J¢ > state. The sum is over all ½ g¢J¢ > states with E( g¢J¢) < E(gJ).

According to Cowan [3] the Einstein probability rate is related to gf through the following relation:

In order to obtain better values for oscillator strengths, we calculated the reduced matrix elements P1 by using optimized values of energy parameters which were adjusted from a least-squares procedure. In the adjustment, the code tries to fit the energy values to experimental ones by varying the electrostatic parameters. After, the improved wavenumbers are used in eq. (4) and and coefficients are used in eq. (8). The theoretical predictions for the energy levels of the configurations were obtained by diagonalizing of the energy matrices with appropriate option Hartree-Fock relativistic (HFR) using the computer code developed by Cowan [3].

The energy level values were determined from the observed wavelengths by an interactive optimization procedure using the program ELCALC(Energy Level Calculations), where the individual wavelengths are weighted according to their uncertainties [4]. The energy levels adjusted by this method were used to optimize the electrostatic parameters by a least-squares procedure, and finally these optimized parameters were used to calculate the gf-values. This method produces gf-values that are in better agreement with the line intensity observed, compared with gf exclusively theoretical.

3 Results and discussion

We have calculated the theoretical Hartree-Fock values for atomic parameters of some Cu I configurations. The picture we used to perform the theoretical calculations: for even-parity configurations, the 3d104s, 3d94s2, 3d104d, and 3d94s5s are involved and for odd-parity configurations, the 3d104p and 3d94s4p are studied. Due to the high configuration interaction value, we have also included the configurations 3d94p2 and 3d94p5p to improve the even-parity estimatives and configuration 3d105p into the theoretical calculation of the odd-parity states. Table 1 shows only the energy parameters for the configurations that are in focus of attention where appear some values for the configuration integral which are relevant in the present case. The Fig. 1 shows an illustration of a semi-empirical results for some Cu I lines, where we present a plot of oscillator strengths versus wavelengths. The figure represents the spectral intensity distribution for copper lines related to the array transitions studied here.


Baoming and Hongzhi [5] have studied experimentally some Cu I transitions that are used in this work. Measurement of relative intensities of cupper lines are listed in this work. The atomic parameters used to perform the coefficients calculation of equation (1) are shown in Table 2, where is showed the experimental transition probabilities and semi-empirical transition probabilities calculated here. The Fig. 2 shows the linear Boltzmann plot of equation (1) using the results of Baoming et al., that gives a plasma temperature of 5946.9 K. The Fig. 3 shows a similar result (T=5739.3 K) to plasma temperature using the semi-empirical atomic parameters determined here.



4 Conclusions

We hope that the semi-empirical method described in this work can be successfully applied to calculate electron temperature in plasmas. The semi-empirical oscillator strengths calculated by the fitting between theoretical and experimental energy levels produces very good values. This semi-empirical method produces a very good linear relationship between ln (Il3/gf ) and Eu. Its applicability goes beyond the visible range and may be used in vacuum ultra violet range too. We have made a study of some Cu I lines and determined the plasma temperature of a DC plasma discharge that are in acordance with expected. Also, our result is in a very good agreement with the result of Baoming and Hongzhi. The semi-empirical method of measuring temperature gave a difference of 3.5 %.

We present here the oscillator strengths for some known electric dipole transitions in Cu I. The present work is part of an ongoing program, whose goal is to obtain weighted oscillator strength, gf, and lifetimes for elements of astrophysical importance. The ions S VII [7], S IX and S X [8], have been concluded.

Acknowledgements

This work was financially supported by the Conselho Nacional de Desenvolvimento Científico e Tecnológico, CNPq (Brazil), Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES (Brazil), and by Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro, FAPERJ (Brazil).

Received on 26 January, 2004; revised version received on 28 April, 2004

  • [1] H. R. Griem, Plasma Spectroscopy, McGraw-Hill: New York (1964).
  • [2] I. Sobelman, Atomic Spectra and Radiative Transitions Springer: Berlin (1979).
  • [3] R. D. Cowan, The Theory of Atomic Structure and Spectra Berkeley, Univ California Press (1981).
  • [4] L. J. Radziemski and V. Kaufman, J. Opt. Soc. Am. 59, 424 (1969).
  • [5] Baoming Li and Hongzhi Li, 19th International Symposium of Ballistics, 7-11 May 2001, Interlaken, Switzerland.
  • [6] C. H. Corliss and W. R. Bozman, Experimental Transition Probabilities for Spectral Lines of Seventy Elementes, Washington: National Bureau of Standards Monograph S3, U. S. Government Printing Office (1962).
  • [7] F. O. Borges, G. H. Cavalcanti, A. G. Trigueiros, and C. Jupén, J. Quant. Spectrosc. Radiat. Transfer 83, 751 (2004).
  • [8] F. O. Borges, G. H. Cavalcanti, and A. G. Trigueiros, J. Quant. Spectrosc. Radiat. Transfer 78, 119 (2003).

Publication Dates

  • Publication in this collection
    01 Mar 2005
  • Date of issue
    Dec 2004

History

  • Accepted
    28 Apr 2004
  • Received
    26 Jan 2004
Sociedade Brasileira de Física Caixa Postal 66328, 05315-970 São Paulo SP - Brazil, Tel.: +55 11 3091-6922, Fax: (55 11) 3816-2063 - São Paulo - SP - Brazil
E-mail: sbfisica@sbfisica.org.br