Square-Wave Voltammetry Determination of Ciprofloxacin in Pharmaceutical Formulations and Milk Using a Reduced Graphene Oxide Sensor

Abstract

In this paper, a simple, sensitive and precise electroanalytical method was developed using a chemically-reduced graphene-oxide (CRGO)-modified glassy carbon electrode and square wave voltammetry (SWV) for determination of ciprofloxacin in pharmaceutical formulations (tablets) and milk samples. Advantages of this sensor include a potential displacement of 100 mV and a 5-fold current increase for the electrochemical oxidation of ciprofloxacin, which resulted in a highly sensitive sensor, when compared to unmodified electrode. The improved properties of the modified electrode are likely due to the formation of a porous surface evidenced by the change in electrode kinetics (thin-layer diffusion process). The proposed sensor is free from interference of sample matrix (pharmaceutical formulations and low/high-fat milk) avoiding cumbersome processes such as previous separations, solvent extraction, or sample filtration (samples were only diluted in Britton-Robinson buffer solution). The results by SWV showed a limit of detection of 0.21 µmol L-1 (correspondent to 0.069 mg L-1), which is lower than the ones obtained using other carbon-based electrodes, relative standard deviations lower than 12%, and satisfactory recoveries in the range from 84 to 109%. The results obtained were statistically similar (95% confidence level) with those performed through high-performance liquid chromatography (HPLC).

Keywords:
chemically-reduced graphene-oxide; ciprofloxacin; pharmaceutical formulations; milk; square wave voltammetry


Introduction

Ciprofloxacin (CIP) [1-cyclopropil-6-fluoro-4-oxo-7-piperazin-1-ylquinoline-3-carboxilic acid] is a synthetic chemotherapeutic agent used to treat severe and life-threatening bacterial infections.11 Pulgarin, J. A. M.; Molina, A. A.; Boras, N.; Anal. Methods 2012, 4, 3413.,22 Montes, R. H. O.; Marra, M. C.; Rodrigues, M. M.; Richter, E. M.; Muñoz, R. A. A.; Electroanalysis 2014, 26,432. CIP has been widely used in clinical practice because of its low toxicity, wide antibacterial spectrum and low ability to cause bacterial resistance.33 Anacleto, S. S.; Borges, M. M. C.; de Oliveira, H. L.; Vicente, A. R.; Figueiredo, E. C.; de Oliveira, M. A. L; Borges, B. J. P.; de Oliveira, M. A.; Borges, W. S.; Borges, K. B.; J. Pharm. Anal. 2018, 8, 168. It provides effective treatment for a variety of infections particularly those of the urinary tract, respiratory tract, gastrointestinal tract, skin and soft tissues.44 Vella, J.; Busuttil, F.; Bartolo, N. S.; Sammut, C.; Ferrito, V.; Serracino-Inglott, A.; Azzopardi, L. M.; LaFerla, G.; J. Chromatogr. B: Biomed. Sci. Appl. 2015, 989, 80.

The use of CIP in veterinary practices is widespread not only for the therapeutic treatment of livestock, but also for the prevention and etiology of microbial diseases.55 Kalunke, R. M.; Grasso, G.; D'Ovidio, R.; Dragone, R.; Frazzoli, C.; Microchem. J. 2018, 136, 128. The presence of antibiotic residues is one of the main chemical contamination in milk and dairy products.66 Maluf, R. S.; Ribeiro, A.; SaBio - Revista de Saúde e Biologia 2012, 7, 30. The milk contaminated with antibiotics is considered inappropriate for human consumption and signifies a risk for public health. Besides, there is the possibility of interference in technological production processes.66 Maluf, R. S.; Ribeiro, A.; SaBio - Revista de Saúde e Biologia 2012, 7, 30.,77 Idowu, O. R.; Peggins, J. O.; J. Pharm. Biomed. Anal. 2004, 35,143. Hence, the use of antibiotics in cattle was strictly regulated, for example, in the European Union the maximum residue limit of CIP in milk is 0.1 mg L-1.88 Hu, X.; Goud, K. Y.; Kumar, V. S.; Catanante, G.; Li, Z.; Zhu, Z.; Marty, J. L.; Sens. Actuators, B 2018, 268, 278.

The literature shows different analytical methods for determination of CIP, including high-performance liquid chromatography (HPLC),44 Vella, J.; Busuttil, F.; Bartolo, N. S.; Sammut, C.; Ferrito, V.; Serracino-Inglott, A.; Azzopardi, L. M.; LaFerla, G.; J. Chromatogr. B: Biomed. Sci. Appl. 2015, 989, 80.,77 Idowu, O. R.; Peggins, J. O.; J. Pharm. Biomed. Anal. 2004, 35,143.,99 Szerkus, O.; Jacyna, J.; Gibas, A.; Sieczkowski, M.; Siluk, D.; Matuszewski, M.; Kaliszan, R.; Markuszewski, M. J.; J. Pharm. Biomed. Anal. 2017, 132, 173. spectrophotometry in the ultra-violet (UV) region,1010 Palamy, S.; Ruengsitagoon, W.; Spectrochim. Acta, Part A 2018, 190, 129. chemiluminescence,1111 Vakh, C.; Pochivalov, A.; Koronkiewicz, S.; Kalinowski, S.; Postnov, V.; Bulatov, A.; Food Chem. 2019, 270, 10. biosensor1212 Gil, E. S.; Melo, G. R.; Braz. J. Pharm. Sci. 2010, 46, 375. and capillary electrophoresis.1313 Bannefeld, K. H.; Stass, H.; Blaschke, G.; J. Chromatogr. B: Biomed. Sci. Appl. 1997, 692, 453.,1414 Michalska, K.; Pajchel, G.; Tyski, S.; J. Chromatogr. A 2004, 1051, 267. Electroanalytical methods were also reported for determination of CIP employing screen-printed electrodes1515 Reddy, K. R.; Brahman, P. K.; Suresh, L.; Measurement 2018, 127, 175.,1616 Stefano, J. S.; Cordeiro, D. S.; Marra, M. C.; Richter, E. M.; Munoz, R. A. A.; Electroanalysis 2015, 28, 350. and multiwalled carbon-nanotube modified electrodes.88 Hu, X.; Goud, K. Y.; Kumar, V. S.; Catanante, G.; Li, Z.; Zhu, Z.; Marty, J. L.; Sens. Actuators, B 2018, 268, 278.,1717 Fotouhi, L.; Alahyari, M.; Colloids Surf., B 2010, 81, 110.,1818 Gayen, P.; Chaplin, B. P.; ACS Appl. Mater. Interfaces 2016, 8, 1615. The need to include polymeric films associated with carbon nanotubes was reported for improving the selectivity of the sensor for the analysis of complex samples.1818 Gayen, P.; Chaplin, B. P.; ACS Appl. Mater. Interfaces 2016, 8, 1615. Alternatively, laborious extraction procedures have been described for CIP determination in milk samples to reduce sample matrix effects and for preconcentration.1919 Silva,W. P.; Oliveira, L. H.; Santos, A. L; Souza, V. F.; Trindade, M. A. G.; Food Chem. 2018, 250, 7.

A very explored strand in the development of electrochemical sensors is the chemical modification of the electrode surface, which provides unique characteristics to this material. Carbon materials have been widely used in electroanalysis due to some special features including low cost, wide potential window and low sensitivity to dissolved oxygen.2020 McCreery, R. L.; Chem. Rev. 2008, 108,2646. Since the nobel prize in 2010, graphene has been investigated in various applications.2121 Wang, C.-P.; Chou, C.-P.; Chang, T.-L.; Chou, C.-Y.; Microelectron. Eng. 2018, 189, 69.

22 Mahmoudi, T.; Wang, Y.; Hahn, Y.-B.; Nano Energy 2018 , 47, 51.
-2323 Justino, C. I. L.; Gomes, A. R.; Freitas, A. C.; Duarte, A. C.; Rocha-Santos, T. A. P.; TrAC, Trends in Analytical Chemistry 2017, 91, 53. Reduced graphene oxide (RGO) is a two-dimensional material formed of sp22 Montes, R. H. O.; Marra, M. C.; Rodrigues, M. M.; Richter, E. M.; Muñoz, R. A. A.; Electroanalysis 2014, 26,432. hybridized carbon atoms with a densely packed hexagonal structure and oxy-functional groups.2424 Geim, A. K.; Science 2009, 324,1530. The main properties of this material include excellent adsorptivity and conductivity, high strength and good flexibility for chemical modification and for this reason RGO has appeared as a relevant carbon material in the development of electrochemical sensors.2525 Wang, Z.; Li, L.; Liu, E.; Thin Solid Films 2013, 544, 362.,2626 Rocha, D. P.; Dornellas, R. M.; Cardoso, R. M.; Narcisio, L. C. D.; Silva, M. N. T.; Nossol, E.; Richter, E. M.; Munoz, R. A. A.; Sens. Actuators, B 2018, 254, 701. In recent years, the use of chemically modified electrodes with RGO dramatically increased as a result of the main advantages obtained with this material for sensing, such as gain in sensitivity and detectability compared with bare electrodes and even with other chemical modifiers, due to the electrocatalytic characteristic of graphene-based materials.2020 McCreery, R. L.; Chem. Rev. 2008, 108,2646.,2626 Rocha, D. P.; Dornellas, R. M.; Cardoso, R. M.; Narcisio, L. C. D.; Silva, M. N. T.; Nossol, E.; Richter, E. M.; Munoz, R. A. A.; Sens. Actuators, B 2018, 254, 701.

27 Pruneanu, S.; Biris, A. R.; Pogacean, F.; Socaci, C.; Coros, M.; Rosu, M. C.; Watanabe, F.; Biris, A. S.; Electrochim. Acta 2015, 154, 197.

28 Li, W.; Yang, Y. J.; J. Solid State Electrochem. 2014, 18, 1621.
-2929 Cesarino, I.; Simões, R. P.; Lavarda, F. C.; Batagin-Neto, A.; Electrochim. Acta 2016, 192, 8.

The aim of this work was to investigate the use of RGO in the development of a sensitive and stable electrochemical sensor for the determination of CIP in pharmaceutical formulations (tablets) and milk samples. Improved characteristics obtained with RGO allowed for the direct determination of CIP in a complex sample such as milk without a laborious sample preparation step, using square-wave voltammetry (SWV). For validation of the sensor, the samples were analyzed by high-performance liquid chromatography with UV detection (HPLC-UV).

Experimental

Reagents, solutions and samples

All aqueous solutions were prepared with deionized water with resistivity of at least 18 MΩ cm obtained by Milli-Q purification system (Millipore, Burlington, USA). Graphene oxide (GO) was obtained from Sigma Aldrich (St. Louis, USA) and for its chemical reduction sodium borohydride (Sigma Aldrich, St. Louis, USA) was employed. CIP analytical standard was obtained from Sigma Aldrich (St. Louis, USA). All solutions were freshly prepared just before use. CIP solutions were prepared daily using 10 mmol L-1 acetic acid, before the experiments. Britton-Robinson (BR) buffer solutions with pH values adjusted in the range from 2.0 to 10.0 were used. Two pharmaceutical formulations samples (tablets) were acquired in a local drugstore while four low and high-fat bovine milk samples were purchased in local supermarkets. The excipients present in the pharmaceutical formulations samples are microcrystalline cellulose, povidone, croscarmellose sodium, silicon dioxide, magnesium stearate, copolymer of polyvinyl alcohol polyethylene glycol, macrogol and titanium dioxide. The milk samples contained sodium triphosphate, sodium bisphosphate and sodium monophosphate as stabilizing agents.

Instrumentation

The electrochemical measurements, cyclic voltammetry and SWV were performed with µAutolab Type III potentiostat (Metrohm, Herisau, Switzerland) interfaced to a computer equipped with GPES software (version 4.9.007, Eco Chemie). The working electrode was a glassy carbon electrode (GCE) (Ø 3 mm, Metrohm, Herisau, Switzerland). An Ag/AgCl(sat) electrode and platinum wire were used as reference and auxiliary electrodes, respectively.

Raman spectra were obtained using a LabRAM HR evolution microscope (HORIBA, Kyoto, Japan) using a 532 nm Ar laser.

Synthesis of reduced graphene oxide

Chemically-reduced graphene-oxide (CRGO) from GO was obtained by the chemical reduction with sodium borohydride in the proportion of 1.0 mL of graphene oxide dispersion in water (1.0 mg mL-1) using sonication to 6.0 mg of sodium borohydride. The formation of a black solid was verified as a result of the reaction, identified as CRGO, which was filtered, washed with deionized water and then dried for 24 h in oven at 100 ºC.

Modification of the electrode with CRGO

Prior the modification, the GCE surface was polished in alumina suspension, followed by cleaning with the aid of sonication in deionized water to remove excess of alumina. Next, an aliquot of 10 µL of a dispersion of 1.0 mg mL-1 of CRGO in dimethylformamide was dropped over the GCE surface. The dispersion was sonicated using an ultrasonic bath for 30 min before the obtaining of the aliquot. After drop casting, the electrode was placed in oven at 50 ºC for 30 min to eliminate the solvent and then it was ready to use.

Electrochemical measurements

Preliminary study by cyclic voltammetry

The electroactive area of bare GCE and CRGO-modified GCE was determined by cyclic voltammetry using 1.02 mmol L-1 potassium ferricyanide solution in 0.1 mol L-1 KCl scanning from +0.7 to -0.2 V.

The pH of the supporting electrolyte (from 2.0 to 10.0) was investigated using a 0.04 mol L-1 BR buffer solution by cyclic voltammetry scanning from 0.0 to +1.4 V. The effect of scan rate on the electrochemical oxidation of CIP was investigated by cyclic voltammetry on bare and CRGO-modified electrode in the range between 25 and 200 mV s-1.

SWV determination of CIP

The SWV parameters selected for CIP determination were amplitude, frequency and potential step. A standard solution of CIP of 30 µmol L-1 was used in these studies. The selection was performed in univariate manner based on the highest analytical response, in the ranges from 5 to 85 mV of amplitude, 10 to 80 Hz of frequency and 1 to 12 mV of step potential. The selected parameters of SWV were applied in the determination of CIP in pharmaceutical formulations and milk using the CRGO-modified GCE.

Analytical curves with concentrations ranging from 6 to 40 µmol L-1 were prepared in BR buffer (0.04 mol L-1, pH 6.0) from a standard solution of 1000 µmol L-1 CIP.

The analysis was performed in an electrochemical cell containing 2.0 mL of supporting electrolyte (0.04 mol L-1 BR buffer solution pH 6.0), and the sample volumes were 500 µL for milk and 10 µL for pharmaceutical formulations. Recovery tests were also performed for all the samples in order to evaluate possible sample matrix effects.

Samples preparation for SWV determination

For each analysis of pharmaceutical formulations, one tablet was powdered in a mortar and a portion of 25 mg was weighted and dissolved in 0.04 mol L-1 BR buffer solution (pH 6.0) for the analysis. A filtration procedure was not necessary.

The analysis of milk samples with high and low-fat content was performed using 1.00 mL of sample which was transferred to a 10.00 mL volumetric flask followed by dilution with 0.04 mol L-1 BR buffer solution (pH 6.0).

HPLC analysis

High-performance liquid chromatography (HPLC) analyses were carried out in a Shimadzu LC-6AD (Kyoto, Japan) autosampler (SIL-10AF) equipped with an UV-Vis diode array detector (SPD-M20A) and a C18 column (250 mm × 4.60 mm, 5 µm, Phenomenex, Torrance, EUA). The mobile phase was composed of a mixture of 0.017 mol L-1 phosphate buffer and methanol (40:60, v/v) using the isocratic mode. The C18 column was used at 40 ºC, with a flow rate of 1.0 mL min-1, injection volume of 50 µL, and UV detection at the wavelength of 278 nm. Prior HPLC analyses, the pharmaceutical formulations samples were dissolved directly in the solvent, and filtrated with syringe filters of PTFE (polytetrafluoroethylene) membrane (0.45 µm porosity, Millipore, Burlington, MA, EUA).

Results and Discussion

Characterization of RGO

Figure 1 shows the Raman spectra of GO and CRGO materials. Two main bands (D and G) are observed, the first one related to disorder or defects in the structure (at 1350 cm-1), and second one (at 1580 cm-1) related to sp22 Montes, R. H. O.; Marra, M. C.; Rodrigues, M. M.; Richter, E. M.; Muñoz, R. A. A.; Electroanalysis 2014, 26,432. carbon.3030 Ambrosi, A. Pumera, M.; Chem. - Eur. J. 2015, 22, 153. After chemical reduction of GO with sodium borohydride to produce the CRGO, a decrease in the D/G ratio was verified which indicates the recovery of the sp22 Montes, R. H. O.; Marra, M. C.; Rodrigues, M. M.; Richter, E. M.; Muñoz, R. A. A.; Electroanalysis 2014, 26,432. carbon orientation due to the chemical reduction process that results in increase in electron conductivity.3131 Yigit, A.; Yardim, Y.; Çelebi, M.; Levent, A.; Senturk, Z.; Talanta 2016, 158, 21.

Figure 1
Raman spectrum of the CRGO and GO.

Electroactive area of unmodified and modified electrodes

The electroactive area was estimated using cyclic voltammetry (from +0.70 to -0.20 V) with an electrochemical cell containing 1.02 mmol L-1 K3[Fe(CN)6] in KCl (100 mmol L-1). Sequential measurements varying the scan rate (from 10 to 250 mv s-1) generated linear increases in the peak current. Applying the Randles Sevik equation, it was possible to determine the electroactive areas of the unmodified and modified electrode, which were (5.60 ± 0.34) and (7.05 ± 0.09) mm2, respectively. In this sense, it can be inferred that the modification with CRGO provided an increase of 26% in electroactive area.

Electrochemical behavior of CIP on unmodified and modified electrode

The electrochemical behavior of CIP was studied using cyclic voltammetry (0.0 to +1.4 V) and comparing both unmodified and modified electrodes. Figure 2A shows the cyclic voltammograms for the oxidation processes of a CIP standard solution (500 µmol L-1) in BR buffer (0.04 mol L-1, pH 6.0). The electrochemical oxidation of CIP using GCE is irreversible with a peak at +1.20 V. Using the CRGO-modified electrode, an irreversible peak at +1.10 V and a current gain of 5-fold was observed, showing a possible electrocatalytic effect of CRGO. Using GO as the chemical modifier, the analytical signal was not verified, due to the insulating property of the material, which made electron transfer difficult.3232 Dreyer, D. R.; Park, S.; Bielawski, C. W.; Ruoff, R. S. F.; Chem. Soc. Rev. 2010, 39, 228.

Figure 2
(A) Cyclic voltammograms of (a) GO/GCE, (b) bare GCE, (c) CRGO/GCE in CIP 500 μmol L−1 (scan rate: 100 mV s-1); (B) cyclic voltammograms of 200 μmol L−1 CIP at scan rate from 25-200 mV s-1 using CRGO. The reference electrode was Ag/AgCl(sat), the supporting electrolyte was BR buffer (0.04 mol L-1, pH 6.0).

The mass transport of CIP species onto the electrode surface was evaluated by cyclic voltammetry, performing experiments in the scan rate range from 25 to 200 mV s-1 in the presence of CIP (200 µmol L-1). The plots of peak current (Ip) vs scan rate showed good linearity (R2 > 0.99) for CIP obtained on the modified electrode CRGO (Figure 2B), indicating that the electrochemical process was controlled by adsorption of the electroactive species onto the CRGO-modified surface. A different behavior was verified on the unmodified GCE, as a plot of square root of scan rate presented a linear behavior with the peak current which indicates that the electrochemical oxidation of CIP is controlled by diffusion of the species to the electrode.

Therefore, the modification of the GCE surface with CRGO altered the mass transport regime to a thin-layer diffusional process, which may be explained by the formation of a porous thin layer of CRGO over the electrode surface that may confine the CIP species within the CRGO film. A similar result was already verified in the literature for CRGO-modified electrodes2626 Rocha, D. P.; Dornellas, R. M.; Cardoso, R. M.; Narcisio, L. C. D.; Silva, M. N. T.; Nossol, E.; Richter, E. M.; Munoz, R. A. A.; Sens. Actuators, B 2018, 254, 701. as well as carbon-nanotube modified electrodes1717 Fotouhi, L.; Alahyari, M.; Colloids Surf., B 2010, 81, 110.,3333 Sims, M. J.; Ress, N. V.; Dickinson, E. J.; Compton, R. G.; Sens. Actuators, B 2010, 144,158.,3434 Montes, R. H. O.; Stefano, J. S.; Richter, E. M.; Munoz, R. A. A.; Electroanalysis 2014, 26, 1449. and carbon black-modified electrodes.3535 dos Santos, W. T. P.; Amin, H. M. A.; Comptom, R. G.; Sens. Actuators, B 2019, 279, 433.

In the study of mass transport on the modified electrode, the shift of the peak potential (Ep) as the scan rate (v) varied was clearly verified, obtaining a linear relation between Ep and log v (Figure 3).

Figure 3
Study of Ep × log v of the oxidation process of the CIP using 200.0 μmol L−1, scan rate from 25-200 mV s-1 and CRGO electrode.

From the linear adjustment, equation 1 was obtained:

(1) Ep V = 1 . 145 + 0 . 064 log v Vs 1 R 2 = 0 . 987

which according to Laviron3636 Laviron, E.; J. Electroanal. Chem. 1979, 101, 19. can be described as follows (equation 2):

(2) Ep V = A + 2 . 303 RT 1 α nF log v

where A is a constant related to the formal electrode potential (E0) and standard rate constant at E0; a is the transfer coefficient that characterizes the effect of electrochemical potential on activation energy of an electrochemical reaction; n is the number of electrons involved in the rate-controlling step; R, T, and F are the gas constant, temperature and Faraday constants, respectively.

According to the slope of the linear adjustment, the calculated number of electrons was 1.84 (a = 0.5), suggesting that the electrochemical oxidation of CIP involved two electrons.

Preliminary tests employing cyclic voltammetry and the CRGO-modified electrode showed that the electrochemical process involving CIP is pH dependent. The effect of pH on the oxidation of CIP (200 µmol L-1) was investigated in a pH range between 2.00 and 10.00 using BR buffer solutions. The results in Figure 4 shows the investigation of potential (a) and current peak (b) as a function of five different pH values using the CRGO-modified electrode. It is observed that in values of pH 6.0, 8.0 and 10.0 there is a displacement of oxidation peak to more cathodic potentials. However, higher analytical signal was observed in BR buffer solution of pH 6.0, which was thus selected for further studies involving the determination of CIP.

Figure 4
(a) Study of Ep × pH and (b) Ip × pH on the oxidation process, in the pH range from 2 to 10, using 200 μmol L-1 of CIP and CRGO modified electrode.

Figure 4a shows the linear relationship between Ep and pH. The slope of the linear adjustment (Ep × pH) was equal to 50 mV ph-1, which is close to the theoretical value of 59 mV ph-1. Therefore the number of protons involved in the oxidation of CIP is equal to the number of electrons. Figure 5 shows the oxidation mechanism of CIP, which is consistent with other studies in the literature.1515 Reddy, K. R.; Brahman, P. K.; Suresh, L.; Measurement 2018, 127, 175.

Figure 5
Proposed reaction for the electrochemical oxidation of CIP.

SWV determination of CIP

Selection of the instrumental parameters

The SWV technique was selected due to higher sensitivity and speed. The selection of the SWV parameters (amplitude, step and frequency) were based on the highest analytical signal of CIP and precision. The studied ranges were 5-85 mV of amplitude, 1-10 mV of step and 10-80 Hz of frequency and the values selected for further SWV determination of CIP were 35 mV, 10 mV and 40 Hz, respectively, which resulted in the scan rate value of 400 mV s-1.

Figures of merit of the proposed sensor for CIP determination in pharmaceutical formulations and milk samples

Using the selected SWV parameters, a linear relationship between peak current and CIP concentration (R2 = 0.991) was obtained in a range of 6 and 40 µmol L-1 (Figure 6). The limit of detection (LOD) and quantification (LOQ) values were obtained from the standard deviation of blank and the slope of the analytical curve. The LOD and LOQ values were calculated as 0.21 and 0.70 µmol L-1, respectively. The repeatability and accuracy of the developed method was verified by triplicate analyses and recovery tests were performed.

Figure 6
Analytical curve of CIP in the range of 6-40 μmol L-1, (a) BR buffer (pH 6.0, 0.04 mol L-1), (f) 40 μmol L-1 of CIP. The inset presents the respective calibration plot.

The LOD of the sensor 0.21 µmol L-1 (corresponds to 0.069 mg L-1) is lower than the maximum level of CIP allowed in milk (0.1 mg L-1). In this sense, the sensor showed adequate detectability regarding the legislation for CIP content in milk samples.

An important characteristic observed for the modified electrode was its stability of at least 1 day under intense use in the presence of CIP standard. Electrode surface modification studies (n = 10) were performed and it was observed that for a fixed CIP concentration of 13 µmol L-1 using SWV, the relative standard deviation of the current measurement was 7%. Thus, a very repetitive signal was maintained proving the reproducible electrode modification with CRGO.

The developed sensor was compared to other sensors for the determination of CIP reported in the literature (Table 1). The CRGO-modified electrode presented improved detectability in comparison to BDD and most MWCNT-modified electrodes exception to the Nafion (Nafion, polymeric anion exchange modified electrode) and to the electrochemical impendance spectroscopy (EIS) detection, which requires a longer time for a single measurement. Moreover, the proposed sensor was satisfactory applied to milk and drug samples.

Table 1
Comparison of electrochemical sensors for determination of ciprofloxacin

Initially, two pharmaceutical formulations with a nominal CIP mass of 500 mg were analyzed. Table 2 shows the obtained mass, recovery values and comparison with HPLC.

Table 2
Results obtained by analysis of CIP in pharmaceutical formulations

The results obtained by the proposed method were in agreement with those obtained by HPLC. At the 95% confidence level, the calculated t-test values were smaller than the critical value (12.70), which indicates that there were no significant differences between the results.

The mass values obtained for CIP in the pharmaceutical formulations samples were in agreement with the nominal mass (500 mg), the relative standard deviations were below 12% and the recoveries were satisfactory, showing that the method was precise and accurate.

The CIP concentration in all milk samples was below the limit of detection. In this sense, to evaluate the accuracy of the developed method, all samples were spiked with 500 µmol L-1 of CIP, which corresponded to 10 µmol L-1 of CIP in the electrochemical cell. The milk samples were only diluted in supporting electrolyte before analysis. Figure 7 shows the voltammogram obtained for the analysis of high-fat milk 1 and Table 3 shows the obtained results.

Figure 7
Voltammogram obtained for analysis of high-fat milk 1 sample (a), and the high-fat milk 1 sample spiked with 500 μmol L-1 of CIP (b).

Table 3
Recovery values obtained in high and low-fat milk samples

It can be seen in Table 2 that the recovery values were satisfactory (84-109%), and thus it is noticed that constituents of milk samples did not interfere in the analysis. The relative standard deviations were lower than 12%, values that are acceptable considering the concentration level (10-20 µmol L-1) used in the electrochemical cell. Therefore, the proposed graphene-based sensor is able to monitor CIP after a simple dilution of milk samples not requiring a laborious extraction procedure or an additional polymeric film to maintain the electroactivity of the sensor.1818 Gayen, P.; Chaplin, B. P.; ACS Appl. Mater. Interfaces 2016, 8, 1615.,1919 Silva,W. P.; Oliveira, L. H.; Santos, A. L; Souza, V. F.; Trindade, M. A. G.; Food Chem. 2018, 250, 7.

Interference test with other antibiotics (chloramphenicol, amoxicillin, tetracycline, sulfachlorpyridazine) also used by veterinary medicine were not performed. However, it has been verified through literature studies using carbon-based sensors that these antibiotics respond at other potential ranges.4141 Kor, K.; Zarei, K.; J. Electroanal. Chem. 2014, 733,39.

42 Guo, G.; Zhuo, F.; Xiao, F.; Zeng, B.; Int. J. Electrochem. Sci. 2009, 4, 1365.

43 Rezaei, D.; Damiri, S.; Electroanalysis 2009, 21, 1577.
-4444 Aleixo, H.; Okumura, L. L.; Gurgel, A. F. S. S.; Diniz, J. A.; Anal. Methods 2019, 11, 1743.

Conclusions

In the present work, an electrochemical sensor (CRGO-modified electrode) was developed from the chemical reduction of graphene oxide, which conferred potential displacement and considerable gain of analytical signal (5-fold) to CIP detection. The proposed method using SWV and the CRGO-modified GCE was optimized and applied for the determination of CIP in pharmaceutical formulations and milk samples, with adequate detectability (LOD = 0.21 µmol L-1, 0.069 mg L-1), precision (RSD < 12%) and acceptable accuracy (recovery in the range of 84 and 109%). The analytical characteristics of the proposed sensor are superior in comparison with the ones obtained with other carbon materials previously reported in the literature. The concentrations of CIP in the milk samples were below the limit of detection, and the values determined in the pharmaceutical formulations ranged from 496 to 505 mg, which was consistent with the HPLC results and label values of the commercial drugs. In addition, the electrochemical method did not require time-consuming sample handling (simple dilution) or expensive instrumentation.

Acknowledgments

This research was supported by FAPEMIG (Research Support Foundation of the State of Minas Gerais) (process: APQ-02010-16), CNPq (National Council for Scientific and Technological Development, process: INCTBio 465389/2014-7 and 307271/2017-0), CAPES (Coordination for the Improvement of Higher Education Personnel, financial code 001) and PROPESQ/UFJF.

References

  • 1
    Pulgarin, J. A. M.; Molina, A. A.; Boras, N.; Anal. Methods 2012, 4, 3413.
  • 2
    Montes, R. H. O.; Marra, M. C.; Rodrigues, M. M.; Richter, E. M.; Muñoz, R. A. A.; Electroanalysis 2014, 26,432.
  • 3
    Anacleto, S. S.; Borges, M. M. C.; de Oliveira, H. L.; Vicente, A. R.; Figueiredo, E. C.; de Oliveira, M. A. L; Borges, B. J. P.; de Oliveira, M. A.; Borges, W. S.; Borges, K. B.; J. Pharm. Anal. 2018, 8, 168.
  • 4
    Vella, J.; Busuttil, F.; Bartolo, N. S.; Sammut, C.; Ferrito, V.; Serracino-Inglott, A.; Azzopardi, L. M.; LaFerla, G.; J. Chromatogr. B: Biomed. Sci. Appl. 2015, 989, 80.
  • 5
    Kalunke, R. M.; Grasso, G.; D'Ovidio, R.; Dragone, R.; Frazzoli, C.; Microchem. J. 2018, 136, 128.
  • 6
    Maluf, R. S.; Ribeiro, A.; SaBio - Revista de Saúde e Biologia 2012, 7, 30.
  • 7
    Idowu, O. R.; Peggins, J. O.; J. Pharm. Biomed. Anal. 2004, 35,143.
  • 8
    Hu, X.; Goud, K. Y.; Kumar, V. S.; Catanante, G.; Li, Z.; Zhu, Z.; Marty, J. L.; Sens. Actuators, B 2018, 268, 278.
  • 9
    Szerkus, O.; Jacyna, J.; Gibas, A.; Sieczkowski, M.; Siluk, D.; Matuszewski, M.; Kaliszan, R.; Markuszewski, M. J.; J. Pharm. Biomed. Anal. 2017, 132, 173.
  • 10
    Palamy, S.; Ruengsitagoon, W.; Spectrochim. Acta, Part A 2018, 190, 129.
  • 11
    Vakh, C.; Pochivalov, A.; Koronkiewicz, S.; Kalinowski, S.; Postnov, V.; Bulatov, A.; Food Chem. 2019, 270, 10.
  • 12
    Gil, E. S.; Melo, G. R.; Braz. J. Pharm. Sci. 2010, 46, 375.
  • 13
    Bannefeld, K. H.; Stass, H.; Blaschke, G.; J. Chromatogr. B: Biomed. Sci. Appl. 1997, 692, 453.
  • 14
    Michalska, K.; Pajchel, G.; Tyski, S.; J. Chromatogr. A 2004, 1051, 267.
  • 15
    Reddy, K. R.; Brahman, P. K.; Suresh, L.; Measurement 2018, 127, 175.
  • 16
    Stefano, J. S.; Cordeiro, D. S.; Marra, M. C.; Richter, E. M.; Munoz, R. A. A.; Electroanalysis 2015, 28, 350.
  • 17
    Fotouhi, L.; Alahyari, M.; Colloids Surf., B 2010, 81, 110.
  • 18
    Gayen, P.; Chaplin, B. P.; ACS Appl. Mater. Interfaces 2016, 8, 1615.
  • 19
    Silva,W. P.; Oliveira, L. H.; Santos, A. L; Souza, V. F.; Trindade, M. A. G.; Food Chem. 2018, 250, 7.
  • 20
    McCreery, R. L.; Chem. Rev. 2008, 108,2646.
  • 21
    Wang, C.-P.; Chou, C.-P.; Chang, T.-L.; Chou, C.-Y.; Microelectron. Eng. 2018, 189, 69.
  • 22
    Mahmoudi, T.; Wang, Y.; Hahn, Y.-B.; Nano Energy 2018 , 47, 51.
  • 23
    Justino, C. I. L.; Gomes, A. R.; Freitas, A. C.; Duarte, A. C.; Rocha-Santos, T. A. P.; TrAC, Trends in Analytical Chemistry 2017, 91, 53.
  • 24
    Geim, A. K.; Science 2009, 324,1530.
  • 25
    Wang, Z.; Li, L.; Liu, E.; Thin Solid Films 2013, 544, 362.
  • 26
    Rocha, D. P.; Dornellas, R. M.; Cardoso, R. M.; Narcisio, L. C. D.; Silva, M. N. T.; Nossol, E.; Richter, E. M.; Munoz, R. A. A.; Sens. Actuators, B 2018, 254, 701.
  • 27
    Pruneanu, S.; Biris, A. R.; Pogacean, F.; Socaci, C.; Coros, M.; Rosu, M. C.; Watanabe, F.; Biris, A. S.; Electrochim. Acta 2015, 154, 197.
  • 28
    Li, W.; Yang, Y. J.; J. Solid State Electrochem. 2014, 18, 1621.
  • 29
    Cesarino, I.; Simões, R. P.; Lavarda, F. C.; Batagin-Neto, A.; Electrochim. Acta 2016, 192, 8.
  • 30
    Ambrosi, A. Pumera, M.; Chem. - Eur. J. 2015, 22, 153.
  • 31
    Yigit, A.; Yardim, Y.; Çelebi, M.; Levent, A.; Senturk, Z.; Talanta 2016, 158, 21.
  • 32
    Dreyer, D. R.; Park, S.; Bielawski, C. W.; Ruoff, R. S. F.; Chem. Soc. Rev. 2010, 39, 228.
  • 33
    Sims, M. J.; Ress, N. V.; Dickinson, E. J.; Compton, R. G.; Sens. Actuators, B 2010, 144,158.
  • 34
    Montes, R. H. O.; Stefano, J. S.; Richter, E. M.; Munoz, R. A. A.; Electroanalysis 2014, 26, 1449.
  • 35
    dos Santos, W. T. P.; Amin, H. M. A.; Comptom, R. G.; Sens. Actuators, B 2019, 279, 433.
  • 36
    Laviron, E.; J. Electroanal. Chem. 1979, 101, 19.
  • 37
    Garbellini, G. S.; Rocha-Filho, R. C.; Fatibello-Filho, O.; Anal. Methods 2015, 7, 3411.
  • 38
    Silva, L. A. J.; Stefano, J. S.; Cardoso, R. M.; Prado, N. S.; Soares, P. H. T.; Nossol, E.; Munoz, R. A. A.; Angnes, L.; Richter, E. M.; J. Electroanal. Chem. 2019, 833, 560.
  • 39
    Ensafi, A. A.; Taei, M.; Khaymian, T.; Hasanpour, F.; Anal. Sci. 2010, 26, 803.
  • 40
    Al-Ghamdi, A. F.; Bani-Yassen, A. D.; Russ. J. Electrochem. 2014, 50, 355.
  • 41
    Kor, K.; Zarei, K.; J. Electroanal. Chem. 2014, 733,39.
  • 42
    Guo, G.; Zhuo, F.; Xiao, F.; Zeng, B.; Int. J. Electrochem. Sci. 2009, 4, 1365.
  • 43
    Rezaei, D.; Damiri, S.; Electroanalysis 2009, 21, 1577.
  • 44
    Aleixo, H.; Okumura, L. L.; Gurgel, A. F. S. S.; Diniz, J. A.; Anal. Methods 2019, 11, 1743.

Publication Dates

  • Publication in this collection
    16 Sept 2019
  • Date of issue
    Sept 2019

History

  • Received
    23 Feb 2019
  • Accepted
    22 May 2019
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br