Acessibilidade / Reportar erro

Synthesis and Characterization of Nanopore MoVI-Imprinted Polymer and Its Application as Solid Phase for Extraction, Separation and Preconcentration of Molybdenum Ions from Water Samples

Abstract

The purpose of this study is to prepare a new ion imprinted polymer for MoVI with high selectivity. Ion-imprinted polymer (IIP) particles were synthesized by thermally copolymerization. For the synthesis of the ion imprinted polymer, the ion pair of (MoVI-thiocyanate) and NR4+ was used. The ion pair was precipitated in an aqueous phase and then dissolved in acetonitrile as a porogen. The imprinted ion was removed using 10% (v/v) methanol in HCl (0.5 mol L-1). The unleached and leached IIP particles were characterized by infrared spectroscopy, thermogravimetric analysis, surface area analysis, scanning electron microscopy and energy dispersive X-ray analysis. The use of the new MoVI-IIP in solid phase extraction revealed a maximum adsorption capacity of 3.77 mg MoVIper gram of MoVI-IIP in optimum conditions of extraction. The selectivity coefficients of the IIP for Mo in comparison with other metal ions were also evaluated. The proposed Mo-IIP was successfully applied for MoVI determination in different types of water samples.

Keywords:
ion imprinted polymer; molybdenum(VI); thermal copolymerization; solid phase extraction


Introduction

Molybdenum is a biologically important trace element, which occurs in various oxidation states in minerals rather than as free metal. Molybdenum in real water exists in the form of MoO42− ion and this form (MoVI) is generally assumed to be the dominant oxidation state in oxic natural waters, while MoV is thermodynamically stable in reducing waters.11 Du, J. X.; Li, J. J.; Yang, L. J.; Lu, J. R.; Anal. Chim. Acta 2003, 481, 239.,22 Wang, D.; Aller, R. C.; Sanudo-Wilhelmyc, S. A.; Mar. Chem. 2009, 113, 250. Molybdenum ions play an important role in enzymatic processes, and stimulate the synthesis of proteins and nucleic acids.33 Schindelin, H.; Kisker, C.; Hilton, J.; Rajagopalan, K. V.; Rees, D. C.; Science 1996, 272, 1615. Its deficiency may results in reduced growth or yield loss and even death due to accumulating nitrate, reducing amino acid concentration and falling level of vitamin metabolism in plant tissue.44 Llamas, A.; Tejada-Jimenez, M.; Fernandez, E.; Galvan, A.; Metallomics 2011, 3, 578. It is, however, toxic at high concentrations for both plant and human causing bone deformation and disturbances in the metabolism of fats and proteins in human.55 Marczenko, Z.; Lobinski, R.; Pure Appl. Chem. 1991, 63, 1627. Molybdenum is used as a component in glass, fertilizer, catalyst, lubricant and alloy of steel. As a result, industrial effluents contain excess of molybdenum that causes detrimental effects in animals and human beings. Very low concentrations of MoVI can be found in water supplies such as river, spring and well water. Therefore, it is important to develop a sensitive and selective method of Mo environmental monitoring to know the exposure level of this element. Mo limit in drinking water declared by environmental protection agency (EPA) is 90 µg L-1. For the determination of trace amount of Mo, a separation and a preconcentration step are usually required before its analysis. This is due to its low concentration and matrix effect in environmental samples. One of the most common methods for preconcentration and separation of analytes is solid phase extraction (SPE). Solid phase extraction is an attractive technique based on the use of a sorbent that retains the analytes. The analytes are eluted from the sorbent using a suitable solvent. SPE technique reduces solvent consumption and exposure along with, disposal cost and extraction time. Recently, imprinting polymers have been successfully utilized for the preconcentration and separation of trace analytes from water samples.

Molecular imprinted polymers (MIPs) have been developed over the years for carbohydrate, amino acids and their derivatives.66 Haupt, K.; Mosbach, K.; Chem. Rev. 2000, 100, 2495. Molecular imprinting is a technique for preparing polymeric materials that are capable of high molecular recognition. The resultant imprints possess a steric and chemical memory for the template. In molecular imprinting process, selected functional monomers are polymerized around a target molecule (template) in presence of a crosslinking agent.77 Shea, K. J.; Trends Polym. Sci. 1994, 2, 166.

8 Wulff, G.; Angew Chem., Int. Ed. 1995, 34, 1812.
-99 Takeuchi, T.; Haginaka, J.; J. Chromatogr. B: Biomed. Sci. Appl. 1999, 728, 1. After removal of the template trapped in a highly crosslinked polymeric matrix, selective cavities together with the shape of the template are created.1010 Segatelli, M. G.; Santos, V. S.; Presotto, A. B. T.; Yoshide, I. V. P.; Tarley, C. R. T.; React. Funct. Polym. 2010, 70, 325. For metal ions, molecular imprinting can be interpreted as an ionic imprinting. Ion imprinted polymers (IIPs) are similar to MIPs, but they recognize inorganic ions after imprinting.1111 Dekova, I.; Karadjova, I.; Ivanov, I.; Georgieva, V.; Eutimova, B.; Georgiev, G.; Anal. Chim. Acta 2007, 584, 196.

12 Birlik, E.; Ersz, A.; Denizli, A.; Say, R.; Anal. Chim. Acta 2006, 565, 145.
-1313 Chang, X.; Jiang, N.; Zheng, H.; He, Q.; Hu, Z.; Zhai, Y.; Cui, Y.; Talanta 2007, 71, 38. The selectivity of an ion imprinted polymer is based on the metal ion interaction with a specific ligand, coordination geometry, metal ion coordination number, charge and size.1414 Mages, A. G.; Whitcombe, M. J.; Adv. Drug Delivery Rev. 2005, 57, 1742.

15 Dakova, I.; Karadjova, I.; Georgieva, V. S.; Geargiev, G.; Talanta 2009, 78, 523.

16 Hande, P. E.; Samui, A. B.; Kulkarni, P. S.; Environ. Sci. Pollut. Res. 2015, 22, 7375.
-1717 Fu, J.; Chen, L.; Li, J.; Zhang, Z.; J. Mater. Chem. A 2015, 3, 13598.

There are some reports on the nanopore IIP preparation and their applications as the solid phase extraction (SPE) sorbent for the preconcentration of the analytes present in trace amounts or their separation from other coexisting species in complex matrix.1818 Shirvani-Arani, S.; Ahmadi, J.; Bahrami-Samani, A.; Ghannadi-Maragheh, M.; Anal. Chim. Acta 2008, 623, 82.

19 Shakerian, F.; Dadfarnia, S.; Haji Shabani, A. M.; Food Chem. 2012, 134, 488.
-2020 Arab-zavar, M. H.; Chamsaz, M.; Zohuri, G.; J. Hazard. Mater. 2011, 185, 38. MoVI oxy ion imprinted particle was prepared firstly by the surface metal ion imprinting technique with a sol-gel process on the surface of amino-silica by Ren et al.2121 Ren, Y.; Liu, P.; Ma, J.; Wen, Q.; Zhang, M.; Chem. Eng. J. 2013, 219, 286. They used MoVI oxy ion-imprinted as an adsorbent for preconcentration and separation of MoVI trace amounts from the water samples.

In this work nanopore molybdenum(VI)-imprinted and non-imprinted copolymers were synthesized by using methacrylic acid (MAA) as a monomer, ethylene glycoldimethacrylate (EGDMA), as crosslinking agent, and 2,2'-azobisisobutyronitrile (AIBN) as initiator, after removal of MoVI ions, MoVI-imprinted polymer was used for solid phase extraction and preconcentration of MoVI from aqueous solutions. The different parameters affected on the extraction of Mo ions were optimized by using one variable at a time and chemometric tools (central composite design, CCD). Finally, the analytical application and selectivity behavior of the synthesized materials were described and discussed.

Experimental

Instrumentation

A PerkinElmer (Kentucky, USA) 7300 DV Optima model inductively coupled plasma-atomic emission spectroscopy (ICP-AES) was used for the determination of metal ion. The argon gas with 99.999% (v/v) purity for ICP-AES was purchased from Roham Gas Co. Measurement was made in triplicate under the operating conditions listed in Table 1.

Table 1
Optimized conditions for ICP determination of the Mo ion

The infrared (IR) spectra (400-4000 cm-1) in KBr were recorded with the aid of a Vertex 70 spectrometer (Bruker, Billerica, USA). Thermogravimetric analysis was carried out using the Rheometric scientific simultaneous thermal analyzer (London, England). Nitrogen sorption studies were made by a Quantachrome NOVA instrument (Florida, USA). The morphology of the unleached and leached IIP particles were examined by scanning electron microscopy (SEM), using a Philips XL-30 scanning electron microscope. A peristaltic pump model PD-5101 (Heidolph, Germany) was used in the SPE process. A Metrohm model 744 digital pH meter (Herisau, Switzerland), equipped with a combined glass-calomel electrode was employed for the pH adjustments. A Hettich centrifuge model EBA 20 (Oxford, England) was employed for phase separation.

Chemicals and reagents

Ethylene glycoldimethacrylate (Merck, Darmstadt, Germany), 2,2'-azobisisobutyronitrile (98%, m/m, Acros, USA), methacrylic acid (Sigma-Aldrich, Steinheim, Germany) and tetra-n-butylammonium hydroxide (20%, m/m, Merck, Darmstadt, Germany) were applied for the synthesis of polymers with analytical reagent grades. Hydrochloric acid was obtained from Sigma-Aldrich (Steinheim, Germany). All other chemicals were of analytical reagent grades and they were purchased from Merck (Darmstadt, Germany). Na2MoO4.2H2O (Merck, 99%, m/m) was used as the source of MoVI and nitrate or chloride salts of other cations (all from Merck) were of the highest purity available and were used without any further purification. Stock solution of MoVI (100 µg mL-1) was prepared by dissolving appropriate amounts of Na2MoO4.2H2O in deionized water in a 100 mL volumetric flask. Dilute solutions were prepared by appropriate dilution of the stock solution in deionized water.

Ion-imprinted polymer (IIP) preparation

The synthesis of poly(ethylene glycoldimethacrylate-co-methacrylic acid) was based on the bulk polymerization method. In the first step, the inorganic complex was formed between MoVI and thiocyanate (SCN) in aqueous solution, thereafter the ion pair formed between the Mo-SCN inorganic complex as a bulk anion and tetrabutylammonium (NR4 +) as a bulk cation. For this task, the aqueous solution 1.25 mol L-1 of HCl (500 mL), containing 5.2 × 10-3 mol L-1 of MoVIand 0.1 mol L-1 NaSCN was prepared. Then, 8.2 mL from NR4OH (20%, m/m) was added into the Mo solution. The ion pair was formed and precipitated completely. The red precipitate was separated after 2 days, and it was dissolved in 52 mL acetonitrile. In order to obtain the amount of Mo in acetonitrile, the aqueous solution was analyzed before and after precipitation. The amount of Mo calculated was about 2.3 mmol. 20 mL acetonitrile solution containing 0.9 mmol of molybdenum ion pair, 3 mmol of MAA, 20 mmol of EGDMA and 0.1 g AIBN was transferred into polymerization reactor. Following this procedure, the solution was purged thoroughly with argon gas for 2 min and the reaction flask was sealed immediately. The mixture was subsequently polymerized at 80 ºC for 48 hours. The resulting red solid polymer was dried in an oven at 70 ºC for 4 hours. The IIP was grounded in a mechanical mortar and then it was sieved (≤ 100 µm). The residuary (e.g., unconverted monomer, initiator and solvent) was removed using water/methanol solution (20%, v/v). In order to remove the Mo ions confined in the selective cavity of the polymer, it was washed successively with 10% (v/v) methanol in HCl (0.5 mol L-1) and monitored simultaneously by ICP-AES. Finally, the particles were washed by distilled water and dried in an oven at 70 ºC for 3 hours. To evaluate the imprinting effect of the Mo-imprinted polymer, the same procedure was adopted, in absence of Mo ion pair, which was designed as an non-imprinted polymer (NIP). The IIP and NIP polymers were further characterized by infrared spectroscopy (IR), thermal gravimetric analysis (TGA), SEM, X-ray and Brunauer-Emmett-Teller (BET) techniques.

Solid-phase extraction of MoVI

A total 200 mg of Mo-imprinted polymer was packed into a SPE column (6.0 × 1.0 cm internal diameter), made of polyethylene, a polyethylene frit was placed at both ends to prevent the loss of the polymer during the sample loading. Before loading the sample, SPE cartridge was conditioned by passing 20 mL deionized water at a flow rate of 1.5 mL min-1. Then, 35 mL of the sample containing MoVI, SCN NR4 + in the HCl 3 mol L-1 was passed through the column at flow rate of 1.5 mL min-1 (controlled by a peristaltic pump). In this solution, number of moles of SCN and NR4 + were 600 and 50 moles per each mole of Mo. The column was washed with 7 mL distilled water at a flow rate of 1.5 mL min-1.

Loading capacity

To investigate the loading capacity of IIP, 200 mg of IIP was packed into the SPE column and 20 mL of the sample containing 50 mg L-1 MoVI, and equivalent of each Mo mole, 600 moles of SCN and 70 moles of NR4+ in the HCl 3 mol L-1 media was passed through the column at flow rate of 1.5 mL min-1. The Mo content of the sample was passed through the IIP column measured by ICP. Loading capacity of the polymer was calculated by the following equation:

(1)

where Q is the loading capacity of the polymer (mg g-1); Ci and Cf are the concentrations of the ions in the initial solution and in the aqueous phase after passing through the IIP column, respectively (mg L-1); V is the volume of the aqueous phase (L) and W is the amount of polymer (g).2222 Saraji, M.; Yousefi, H.; J. Hazard. Mater. 2009, 167, 1152.

Selectivity experiments

In order to evaluate the selectivity of the imprinted adsorbent, 20 mg of IIP and NIP were packed into the SPE columns. 2 mL of the aqueous solutions (HCl 3 mol L-1) including MoVI and other metallic ions (Cu2+, Cr3+, Cd2+, Pb2+, Zn2+, Mg2+, Co2+, Fe3+, Mn2+ and U6+) binary mixtures containing 0.25 mg L-1 of Mo and different amount from each metallic ions with 600 moles of SCN and 70 moles of NR4+ equivalent of each mole of Mo were passed through the IIP and NIP columns at the flow rate of 1.5 mL min-1. The concentration of Mo ions in the transit solution through the IIP column was measured by ICP. The parameters related to the selective performance of sorbents, such as distribution (Kd) and selectivity (k) coefficients were determined according to the literature data.2323 Andac, M.; Say, R.; Denizli, A.; J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. 2004, 811, 119. Distribution coefficient was calculated according to:

(2)

where Ci, Cf and Vs represent the initial, final solution concentrations and the volume of the solution, respectively. The selectivity coefficient is defined as the ratio between the distribution coefficient for MoVI ions and the distribution coefficient for interfering ions as k.

(3)

Results and Discussion

Characterization studies

The MoVI-IIP particles were characterized by different characterization techniques. The IR spectra of the NIP, unleached IIP and leached IIP particles were recorded by the KBr pellet method using a vertex spectrometer. The absence of bands in the region of 1638-1648 cm-1 indicates the absence of vinyl groups in the polymer particles. This observation could be possibly attributed to the polymerization of both MAA and EGDMA (Figure 1). The three peaks at 1108, 2042 and 2354 cm-1, just in the spectra of unleached polymer (UIIP), could be attributed to νC-N (in tetrabuthylamonium), νSCN and νC≡N (in SCN) respectively, illustrating that the ion pair was removed completely during the leaching process (LIIP). The IR spectra of NIP and leached IIP were found to be almost similar indicating that all the polymer particles have similar backbones. The C=O stretching vibration at 1728 cm-1in the NIP was shifted to 1722 cm-1 in the UIIP and to 1730 in the LIIP material, showing that the oxygen of C=O group is involved in the Mo interaction.

Figure 1
IR spectra of the (a) NIP; (b) unleached IIP; (c) leached IIP particles.

Figure 2 shows the thermal degradation behaviors of unleached IIP, leached IIP and NIP particles. Unleached IIP presented four main weight loss steps in the ranges: 131-231 ºC, 231-350 ºC, 350-414 ºC and 450-532ºC. Leached IIP presented three main weight loss steps in the ranges: 150-236 ºC, 255-393 ºC and 393-550 ºC, also NIP presented two main weight loss steps in the ranges 255-393 ºC and 432-532 ºC. The first step for unleached IIP in the range of 131-231 ºC and for leached IIP in the range of 150-236 ºC are due to the presence of physisorbed water. In the second step, two pronounced weight losses were observed in unleached IIP within the ranges of 231-350 ºC and 450-532 ºC with maximum degradation temperatures (Tmax) of 341 and 490 ºC respectively, in leached IIP within the ranges of 255-393 ºC and 393-550 ºC with Tmax of 352 and 518 ºC and in NIP within the ranges of 255-393 ºC and 432-532 ºC with Tmax of 332 and 507 ºC which was attributed to the decomposition of poly(EGDMA) segment. The third step, for unleached IIP with Tmax 386 ºC corresponds to the decomposition of the ion pair. For NIP, the end product has higher residual yield (12.5%) when compared with the unleached IIP (5.8%) and leached IIP (0.625%). This difference could be related to the absence of coordination between EGDMA and MAA with the ion pair during synthesis, which can lead to additional interactions between the monomers, resulting in higher residual yield (12.5%) for NIP.

Figure 2
TG and DTG curve for (a) leached IIP; (b) unleached IIP; (c) NIP particles.

The synthesized IIP particles were characterized using nitrogen sorption studies, in order to know the surface properties of the leached IIP, unleached IIP and NIP particles. The surface area was determined by applying the BET equation. The data are recorded in Table 2 for the leached, unleached and non-imprinted polymer particles. It is clearly seen that porosity changes after the removal of molybdenum ions from the IIP particles. A comparison between the surface properties of synthesized IIP and other SPE materials for the extraction and determination of Mo is presented in Table 2.

Table 2
Nitrogen sorption data for leached IIP, unleached IIP and NIP particle

The morphology of the polymers was assessed by SEM. The respective micrographs shown in Figures 3a and 3b, illustrate that the porosity is changed after the removal of the molybdenum ions. In addition, it is clear that the pore size in the leached polymers was in the nano-range, corresponding to the ion size.

Figure 3
SEM images of the (a) unleached; (b) leached IIP particles.

The energy dispersive X-ray (EDX) spectra for the unleached and leached polymer particles confirmed that the absence of molybdenum in EDX spectrum of the leached polymer particles illustrates the complete removal of molybdenum from the polymer matrix in leaching step.

Optimization of sorption and elution of MoVI ions from the IIP particles in the column

The critical variables (e.g., concentrations of HCl, NR4 +, and SCN in the sample and elution condition) affected the extraction of molybdenum ions from water samples and their variation ranges were first selected based on a preliminary one variable at a time (OVAT) procedure, and further optimization was then performed by response surface methodology (RSM), based on rotaTable face central composite design (FCCD).

According to the results obtained by OVAT method, there are several factors such as complex formation time, HCl, SCN and NR4+ concentration in the sample, which may affect the extraction process. To find the optimum condition on the extraction of molybdenum ions from water samples, and to investigate the probable interaction between variables, RSM based on rotatable FCCD was used.

Preliminary OVAT procedure

Various experimental parameters such as concentrations of HCl, NR4 +, SCN in the sample and elution condition which may effect on the extraction of MoVI ions were investigated. 200 mg IIP was packed in the column. The created conditions were chosen by preliminary tests as follows: 20 mL solution containing 1 mg L-1 MoVI, and equivalent of each Mo mol, 400 moles of SCN and 50 moles of NR4+ was prepared. The flow rate of the sample solution through the column was chosen 0.74 mL min-1. In order to elute MoVI from IIP, 10 mL HCl 0.5 mol L-1 was passed through the column at flow rate of 0.26 mL min-1.

HCl concentration effect

The effect of HCl concentration was investigated in the range of 0.15-2 mol L-1 (Figure 4). The maximum percentage of recovery of Mo ions was determined at HCl 2 mol L-1.

Figure 4
Effect of concentration of HCl (?) experimental conditions: sample; 20 mL containing concentration of Mo: 1 mg mL-1; mole of SCN per mole of Mo: 400; mole of NR4+ per mole of Mo: 50; eluent: 10 mL HCl 0.5 mol L-1; sample flow rate: 0.74 mL min-1; eluent flow rate: 0.26 mL min-1. Concentration of SCN (?) experimental conditions: sample; 20 mL containing concentration of Mo: 1 mg mL-1 in HCl 2 mol L-1other conditions are similar on the adsorption of MoVI on the MoVI-imprinted polymer.

NR4+ concentration effect

In these series of experiments, the concentrations of all reagents and conditions were kept constant while the concentration of NR4+ was varied between 0 to 50 moles of NR4+ equivalent of each mole of Mo. Based on the results, 50 moles of NR4+equivalent of Mo mole have the maximum recovery of MoVI from sample waters.

SCN concentration effect

The effect of SCN concentration on the extraction was also examined (Figure 4). In this series of experiments, only the SCN concentration varied in the range 10-500 moles of SCN equivalent of Mo mole. The recovery percentage of MoVI was significantly affected by the concentration of SCN.

Effect of flow rate

The effect of sample and eluent solution flow rate through the column on the retention and recovery of Mo ions was investigated in the range of 0.25 to 1.5 mL min-1. It was found that the adsorption and elution of the metal ions were reproducible in the flow rate range of 0.25 to 1.5 mL min-1. Thus, the flow rates of the sample and eluent solution were adjusted 1.5 mL min-1 throughout the further studies.

Choice of eluent

In order to choose the most effective eluent for quantitative stripping of the retained Mo ions from the column, different eluents such as, HCl (0.5 mol L-1), HCl (0.1 mol L-1), NaOH (0.1 mol L-1) and water was chosen. According to the results, distilled water turned out to be the most effective eluent for quantitative elution. The decrease in elution of Mo at acidic media (pH < 7) is due to the existence of molybdenum in the form of Mo6+. This form of ion is suitable for interaction with SPE pore. At higher pH, molybdenum is converted to MoO42−, so elution was well done. In order to find optimum volume of the elution solvent, different volumes of distilled water from 1 to 10 mL were used; the results are displayed in Figure 5. As seen, quantitative elution was attained using volumes more than 6 mL.

Figure 5
The effect of volume eluent on elution of Mo adsorbed on IIP (experimental conditions: sample; 20 mL containing concentration of Mo: 1 mg mL-1; mole of SCN- per mole of Mo: 500; mole of NR4+ per mole of Mo: 50 in HCl 2 mol L-1; eluent: 10 mL water; sample flow rate: 1.4 mL min-1; eluent flow rate: 1.4 mL min-1).

Response surface methodology

In order to obtain a high recovery and enrichment factor, the effect of different parameters such as time of complex formation, concentration of HCl, amount of SCN and NR4+ in the sample, were analyzed. Response surface methodology including face-center central composite approach was utilized to find the optimum values of effective variables involved in the system.

The design was built up of four factors at three levels (Table 3) with 16 axial points (α = 1). In order to estimate the experimental error, eight replicas at the central point were applied. The design was rotatable, this means that the design had equidistant points from the center. This procedure led to 32 experiments (Table 4), where the experimental results were analyzed by a regression procedure based on the RSM.2525 Deyhimi, F.; Arabieh, M.; Parvin, L.; Biocatal. Biotransform. 2006, 24, 263. Composite design is well known as a useful method to describe the curvature dependency of a typical response to its variables, which needed to explain a non-linear variation behavior. The model that can be fitted to a composite design is an empirical function, determined by the statistical correlation suitability of the observed responses and experimental factors. For this purpose, a second-order four variable-polynomial model equation is usually used (equation 4).2626 Deyhimi, F.; Ahangari, R. S.; Arabieh, M.; Parvin, L.; Int. J. Environ. Anal. Chem. 2006, 86, 1151.

(4)
Table 3
The experimental variables and levels of the FCCD (face central composite design)
Table 4
Design table showing the randomized run order of the experiment, and the uncoded values of the different variables in the experimental design for the determination of the modeled response (equation 4)

where Y is the predicted response. The response here is the percentage of molybdenum ion extraction (Table 3). x1, x2, x3 and x4 are the independent variables or the experimental factors. The linear coefficients a1-a4 express the linear effect of each variable; a11, a22, a33 and a44 coefficients express the quadratic effects; a12-a14, a23-a24 and a34, coefficients express interactive effects between the variables and a0 is a constant corresponding to the central point of experimental variables. The statistical design, data analysis and various plots were obtained by using Minitab statistical software.

The coefficients of the empirical model equation 1 and their statistical characteristics were evaluated (Table 5).

Table 5
Estimated regression coefficients for the quadratic response (equation 4)

The estimated value of the determination coefficient (R2), expressed as a percentage, indicates that the model fits 97.6% of the experimental raw data. The quality of the regression, estimated by the analysis of variance (ANOVA), is shown in Table 6. If the model were a strong predictor of the experimental data, the computed F-value would be higher than the tabular F-value. Generally, the p-levels can be used as a tool to check the significance of each of the regression coefficients. This information is necessary to explain the correlation of the mutual interaction between the factors. The smaller the magnitude of the p, the more significant is the corresponding coefficient. The p-values in Table 6 reveal that one of the interaction terms in model (equation 4) at the 95% confidence level is significant (p < 0.05), while all of the linear, square terms and the remaining of the interaction terms are not significant (p > 0.05). This matter is a confirmation being necessity for a significant correction regarding the number of terms in the model equation 1 and must be regards as ignored terms.

Table 6
Analysis of variance for the quadratic response (equation 4)

Table 6 also shows that, in the model obtained with total terms, "lack of fit F-value" (= 0.031) is also significant with correction regarding the number of terms in model equation 4, when eliminated from time, NR4+ and square term, as well as the obtained ANOVA Table (Table 7) show an improvement in "lack of fit F-value" (= 0.063).

Table 7
Analysis of variance for the quadratic response (equation 4)

A point of maximum response could visually be determined from Figure 6. As demonstrated, the maximum point on the response surfaces has been located in the following values of variables: concentration of HCl = 3 mol L-1 and 600 moles of SCN equivalent of each Mo mole. According to the results of OVAT tests, 70 moles of NR4+ equivalent of each Mo mole is needed to ensure complete extraction of MoVI.

Figure 6
Three-dimensional response surface plots.

Test of optimized extraction

The SPE columns were packed with 20 mg of IIP and NIP. 20 mL HCl solution (3 mol L-1) containing MoVI (0.25 mg L-1), 600 moles of SCN and 70 moles of NR4+ equivalent of each Mo mole was prepared and passed through the columns. The molybdenum ions were eluted from the IIP particles by using 10 mL distilled water. The solution and eluent were passed through the column at flow rate of 1.5 mL min-1. Their content in the eluent were determined by ICP (Table 8).

Table 8
Distributions coefficients of IIP and NIP for MoVI ions under optimum conditions

Loading capacity

The loading capacity is an important factor to evaluate the IIPs. In order to investigate the adsorption capacity of molybdenum on the imprinted polymer particles, 200 mg of polymer particles was packed in a column and a solution of molybdenum under the optimum conditions was passed through the column. The adsorption capacity of the imprinted sorbent calculated was 3.77 mg g-1.

Selectivity studies

The selectivity coefficient (k) is an indicator to express an adsorption affinity of recognition sites for MoVI. Competitive adsorptions of Mo/metal foreign ions in binary mixture solutions were also investigated in column studies. Table 9 summarizes Kd and k values for metal ions of interest with respect to MoVI. All of the cations examined did not interfere with the extraction of MoVI. Since the chloride and nitrate salts employed in this study were without any interference. One important result is that Mo is separated from uranium with the IIP. This feature can be used for Mo remove from uranium in the production process of nuclear fuel.

Table 9
Selectivity parameters (Kd and k) and recovery of 0.25 mg L-1 MoVI from aqueous binary mixture of Mo/metal ions solution by the IIP polymer

Breakthrough volume study

As may be known, breakthrough volume is sample volume that adsorption of analyte is completely performed. To find out breakthrough volume, different volumes (20, 35, 40, 50, 100, 200, 250 and 350 mL) of solution HCl 3 mol L-1 containing 20 µg MoVI and 600 moles of SCN and 70 moles of NR4+ equivalent of each mole of Mo were passed through the IIP (200 mg) column at the flow rate 1.5 mL min-1. Elution of the SPE column was performed with 10 mL of distilled water at the flow rate 1.5 mL min-1. As shown in Figure 7, the recovery value of molybdenum(VI) was quantitative (> 95%) in the sample volume range of 20-35 mL.

Figure 7
Effect of breakthrough volume on the adsorption of MoVI on the IIP particles.

Analytical performance of the method

In order to evaluate the analytical applicability of the polymer particles, SPE method was applied to the extraction and determination of Mo in real water samples. The linearity of the method was evaluated utilizing standard samples at six different concentration levels of molybdenum ions from 10 to 1000 µg L-1. A good linearity with squared correlation coefficient (r2) 0.999 was obtained for calibration curve. Three determination replicates of 500 µg L-1 molybdenum solutions resulted in a relative standard deviation of 4.6%. The limits of detection (LODs) were calculated as the analytes concentration three times the standard deviation of the blank signal, after solid phase extraction of six blank sample with average intensity 10.7 in ICP-AES, divided by the slope of calibration curve (8.66 µg L-1). The enhancement factor, which was calculated from ratio of the slopes of calibration curves obtained with and without solid phase preconcentration method is 2.89 (the linearity of the calibration curve without preconcentration was 200-1000 µg L-1). Tap water and Anzali lake water were tested to check the possible matrix effects and investigate the applicability of the method for real sample analysis. 72 h after sampling in polyethylene containers, the sample was filtered with filter paper (0.45 micron). The samples were divided into three aliquots and the analysis was carried out under the optimal conditions (Table 10). Since no Mo was found in the sample, the water samples were spiked with the Mo (300 µg L-1) to determine the relative recoveries of developed method. These results indicated the ability of the MoVI-imprinted polymer for selective SPE and determination of MoVI in environmental water samples. A comparison between the proposed method and other SPE methods for the extraction and determination of Mo is presented in Table 11. The proposed method has a quantification limit is much less than references 2424 Kononova, O. N.; Kachin, S. V.; Chaikovskaya, A. E.; Kholmogorov, A. G.; Kalyakina, O. P.; Turk. J. Chem. 2004, 28, 193. and 2727 Hayati, F.; Aksu, D.; Apak, R.; Boz, I.; Sens. Actuators, B 2009, 141, 491.. Moreover, the preconcentration factor is equal with reference 2828 Kalal, H. S.; Panahi, H. A.; Framarzi, N.; Moniri, E.; Naeemy, A.; Hoveidi, H.; Abhari, A.; Int. J. Environ. Sci. Technol. 2011, 8, 501. but is less than reference 2929 Jimmy, C. Y.; Chan, S. M.; Chen, Z.; Anal. Bioanal. Chem. 2003, 376, 728..

Table 10
Determination of molybdenum ions in real water samples
Table 11
Comparison of the proposed method with other methods for MoVI determination in water samples

Conclusions

In the present study, MoVI ions imprinted polymers was synthesized by thermal copolymerization of methacrylic acid and ethylene glycol dimethacrylate. For MoVI-IIP synthesis the ion pair between (MoVI-SCN-) and NR4+ was precipitated into aqueous sample and was dissolved into the acetonitrile as a porogen. Various parameters affecting the adsorption of Mo with polymer particles were evaluated and the best conditions for adsorption were found. The selectivity factor of polymer particles for MoVI relative to CrIII, PbII, CdII, MgII, ZnII, CoII, FeIII, MnII and UVI was determined. Due to the high selectivity shown by this new material toward molybdenum ions, it has been successfully employed for the selective separation and preconcentration of molybdenum ions from aqueous systems. In addition, the synthesized Mo-IIP is highly recommended for removing and separating Mo ions from uranium ions.

Acknowledgments

Financial support by Nuclear Fuel Cycle Research School, Nuclear Science & Technology Research Institute (Tehran, Iran) during the period of this research is gratefully acknowledged.

References

  • 1
    Du, J. X.; Li, J. J.; Yang, L. J.; Lu, J. R.; Anal. Chim. Acta 2003, 481, 239.
  • 2
    Wang, D.; Aller, R. C.; Sanudo-Wilhelmyc, S. A.; Mar. Chem. 2009, 113, 250.
  • 3
    Schindelin, H.; Kisker, C.; Hilton, J.; Rajagopalan, K. V.; Rees, D. C.; Science 1996, 272, 1615.
  • 4
    Llamas, A.; Tejada-Jimenez, M.; Fernandez, E.; Galvan, A.; Metallomics 2011, 3, 578.
  • 5
    Marczenko, Z.; Lobinski, R.; Pure Appl. Chem. 1991, 63, 1627.
  • 6
    Haupt, K.; Mosbach, K.; Chem. Rev. 2000, 100, 2495.
  • 7
    Shea, K. J.; Trends Polym. Sci. 1994, 2, 166.
  • 8
    Wulff, G.; Angew Chem., Int. Ed. 1995, 34, 1812.
  • 9
    Takeuchi, T.; Haginaka, J.; J. Chromatogr. B: Biomed. Sci. Appl. 1999, 728, 1.
  • 10
    Segatelli, M. G.; Santos, V. S.; Presotto, A. B. T.; Yoshide, I. V. P.; Tarley, C. R. T.; React. Funct. Polym. 2010, 70, 325.
  • 11
    Dekova, I.; Karadjova, I.; Ivanov, I.; Georgieva, V.; Eutimova, B.; Georgiev, G.; Anal. Chim. Acta 2007, 584, 196.
  • 12
    Birlik, E.; Ersz, A.; Denizli, A.; Say, R.; Anal. Chim. Acta 2006, 565, 145.
  • 13
    Chang, X.; Jiang, N.; Zheng, H.; He, Q.; Hu, Z.; Zhai, Y.; Cui, Y.; Talanta 2007, 71, 38.
  • 14
    Mages, A. G.; Whitcombe, M. J.; Adv. Drug Delivery Rev. 2005, 57, 1742.
  • 15
    Dakova, I.; Karadjova, I.; Georgieva, V. S.; Geargiev, G.; Talanta 2009, 78, 523.
  • 16
    Hande, P. E.; Samui, A. B.; Kulkarni, P. S.; Environ. Sci. Pollut. Res. 2015, 22, 7375.
  • 17
    Fu, J.; Chen, L.; Li, J.; Zhang, Z.; J. Mater. Chem. A 2015, 3, 13598.
  • 18
    Shirvani-Arani, S.; Ahmadi, J.; Bahrami-Samani, A.; Ghannadi-Maragheh, M.; Anal. Chim. Acta 2008, 623, 82.
  • 19
    Shakerian, F.; Dadfarnia, S.; Haji Shabani, A. M.; Food Chem. 2012, 134, 488.
  • 20
    Arab-zavar, M. H.; Chamsaz, M.; Zohuri, G.; J. Hazard. Mater. 2011, 185, 38.
  • 21
    Ren, Y.; Liu, P.; Ma, J.; Wen, Q.; Zhang, M.; Chem. Eng. J. 2013, 219, 286.
  • 22
    Saraji, M.; Yousefi, H.; J. Hazard. Mater. 2009, 167, 1152.
  • 23
    Andac, M.; Say, R.; Denizli, A.; J. Chromatogr. B: Anal. Technol. Biomed. Life Sci. 2004, 811, 119.
  • 24
    Kononova, O. N.; Kachin, S. V.; Chaikovskaya, A. E.; Kholmogorov, A. G.; Kalyakina, O. P.; Turk. J. Chem. 2004, 28, 193.
  • 25
    Deyhimi, F.; Arabieh, M.; Parvin, L.; Biocatal. Biotransform. 2006, 24, 263.
  • 26
    Deyhimi, F.; Ahangari, R. S.; Arabieh, M.; Parvin, L.; Int. J. Environ. Anal. Chem. 2006, 86, 1151.
  • 27
    Hayati, F.; Aksu, D.; Apak, R.; Boz, I.; Sens. Actuators, B 2009, 141, 491.
  • 28
    Kalal, H. S.; Panahi, H. A.; Framarzi, N.; Moniri, E.; Naeemy, A.; Hoveidi, H.; Abhari, A.; Int. J. Environ. Sci. Technol. 2011, 8, 501.
  • 29
    Jimmy, C. Y.; Chan, S. M.; Chen, Z.; Anal. Bioanal. Chem. 2003, 376, 728.

Publication Dates

  • Publication in this collection
    July 2016

History

  • Received
    17 Sept 2015
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br