Acessibilidade / Reportar erro

Quantitative determination of acetaminophen, phenylephrine and carbinoxamine in tablets by high-performance liquid chromatography

Abstract

An alternative methodology for analysis of acetaminophen (Ace), phenylephrine (Phe) and carbinoxamine (Car) in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm) and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1) added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.

acetaminophen; phenylephrine; carbinoxamine


NOTA TÉCNICA

Quantitative determination of acetaminophen, phenylephrine and carbinoxamine in tablets by high-performance liquid chromatography

Carina de A. Bastos; Marcone A. L. de Oliveira* * e-mail: marcone.oliveira@ufjf.edu.br

Departamento de Química, Universidade Federal de Juiz de Fora , 36036-330 Juiz de Fora - MG, Brasil

ABSTRACT

An alternative methodology for analysis of acetaminophen (Ace), phenylephrine (Phe) and carbinoxamine (Car) in tablets by ion-pair reversed phase high performance liquid chromatography was validated. The pharmaceutical preparations were analyzed by using a C18 column (5 μm, 300 mm, 3.9 mm) and mobile phase consisting of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1) added with 1 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate. Isocratic analysis was performed under direct UV detection at 220 nm for Phe and Car and at 300 nm for Ace within 5 min.

Keywords: acetaminophen; phenylephrine; carbinoxamine.

INTRODUCTION

Common colds are a viral disease caused mainly by rhinovirus and coronavirus, consisting of an acute infection of the upper respiratory system mucosa. Infection occurs mainly through direct contact and rarely through sputter, sneezing and cough. Infected people spread the etiologic agent by respiratory secretion such as nasal mucus, which infects hands and objects. The common cold is normally harmless and generally disappears within one or two weeks unless secondary bacterial infection is diagnosed. Once no specific treatment can be given, the usual procedure consists of alleviating the symptoms. The symptomatic treatment is based on the prescription of drugs that alleviate the nasal congestion, dry the mucous membranes and reduce both temperature and pain. This is achieved through drug combination since no single drugs can have all these effects. The pharmaceutical association is often used as they offer a more convenient treatment than single ones.1 Some drugs currently available combine three pharmaceuticals: acetaminophen (Ace), an analgesic and antipyretic; phenylephrine hydrochloride (Phe), a nasal decongestant; and carbinoxamine maleate (Car), an anti-histamine. Figure 1 shows the chemical structure for the three compounds.


Among the classical analytical methodologies used for analysing these pharmaceuticals are: titrimetry,2 spectrometry UV-Visible,2,3 capillary electrophoresis4-6 and high performance liquid chromatography (HPLC).7-18

As regards HPLC methodologies, Barbas et al.16 developed a method for the determination of acetaminophen, phenylephrine hydrochloride and chlorpheniramine maleate using two cyanopropyl columns, a constant proportion of aqueous organic solvent (95:5, v/v) under a gradient of pH from 7.5 to 2.0 with analysis time of 14 min. Shervington et al.18 optimized a method for the determination of acetaminophen and five of its substituted derivatives by reversed phase chromatography system in isocratic mode using mobile phase constituted of water and acetonitrile (70:30, v/v). Erk et al.13 proposed an alternative methodology for determining chorpheniramine maleate and phenylephrine hydrochloride using UV detection at 269 nm and reversed phase in isocratic mode. Lau and Mok14 developed a method for the determination of eight active ingredients in cough-cold syrups, including phenylephrine hydrochloride, using a cyano column and water, acetonitrile and ethanol (36:60:2) containing 1 mmol L-1 perchloric acid as the mobile phase within 22 min.

To our knowledge, the methods described in the literature do not cover the analysis of the association Ace/ Phe and Car/Ace. Therefore, the main contribution of this work was to develop a single separation method for analyzing two different pharmaceutical associations. This method can also be used as a tool in the quality control process of pharmaceutical industry or as an alternative analytical monitoring procedure, which can be used by the supervisory agencies such as Agência Nacional de Vigilância Sanitária (ANVISA). Within this context, a simple alternative methodology for determination of these drugs in tablets using an isocratic chromatographic mode in analysis time of 5 min was proposed. After parameter validation, the method proved to be successful and was applied to the analysis of commercial products containing these active ingredients.

EXPERIMENTAL

Material

Reagents and chemicals

Methanol was of chromatographic grade and all other chemicals were of analytical grade. Phosphoric acid, potassium phosphate monobasic, methanol, ethanol, triethylamine and sodium lauryl sulfate were purchased from Vetec (Rio de Janeiro, RJ, Brazil). Water was purified with Milli-Q®, Milipore System. All solvents and solutions were filtered through a 0.45 μm millipore filter (Milipore® millex-HV filter units) (São Paulo, SP, Brazil).

The following excipients were purchased from Medquímica (Juiz de Fora, MG, Brazil): pregelatinized starch, povidone, stearic acid, microcrystalline cellulose 102, glycolate starch sodium, opadry II 85F19193 translucent, titanium dioxide and 10 yellow dye lacquer (commercial product 1) and pregelatinized starch, povidone, stearic acid, microcrystalline cellulose 102, opadry II 85F19193 translucent, titanium dioxide and yellow dye lacquer 06 (commercial product 2).

Phenylephrine hydrochloride (Phe) (99.9%) and carbinoxamine maleate (Car) (100.0%) were purchased from American Pharmacopoeia (Rockville, MD, USA). Acetaminophen (Ace) (99.8%) was purchased from Brazilian Pharmacopoeia (Rio de Janeiro, RJ, Brazil).

Samples

Twenty tablets of commercial product 1 (CP1) (20.0 mg Phe and 400.0 mg Ace) and commercial product 2 (CP2) (4.0 mg Car and 400.0 mg Ace) were purchased from local pharmacies (Juiz de Fora, MG, Brazil).

Instrumentation

HPLC system: The experiments were performed in a high performance liquid chromatography model Waters 1525 (Milford, (MA), USA) equipped with a photo diode array detector model 2996, a temperature control device maintained at 27 °C and data acquisition and treatment software (Empower Build 1154).

Column: The analytical column was a reversed phase Luna Phenomenex C18 (5 μm, 300 mm x 3.9 mm) (Torrance, CA, USA).

Methods

Sample preparations

Twenty tablets of CP1 and CP2 purchased from local pharmacies were separately weighed and ground to homogeneously fine powders. The powder corresponding to CP1 (20.0 mg Phe and 400.0 mg Ace) and CP2 (4.0 mg Car and 400.0 mg Ace) were weighed and dissolved with 100.0 mL of mobile phase in a separate volumetric flask. Five mL of these solutions were diluted again with mobile phase in another 50 mL volumetric flask and filtered through a 0.45 μm millipore filter in order to obtain clear solutions.

Chromatographic conditions

All analyses were performed at room temperature (about 25 °C) under isocratic conditions. A mobile phase consisted of 60% methanol and 40% potassium monobasic phosphate aqueous solution (62.46 mmol L-1) added with 1.0 mL phosphoric acid, 0.50 mL triethylamine and 0.25 g sodium lauryl sulfate (pH of the whole mixture equal 4.10). Flow rate was 1.0 mL min-1 and volume injection was 50 μL. The UV detection was set at 220 for Car and Phe and at 300 nm for Ace. At the beginning of the day, mobile phase was pumped through the HPLC system during 30 min until achieving baseline stability.

Wavelength selection

The wavelength selection was based on UV-Visible spectra obtained for each compound by means of diode array detector in HPLC system. The wavelengths were selected at 220 for Phe and Car and at 300 nm for Ace (Ace at 220 nm present offset peak signal saturated), as the three compounds presented acceptable peak signal for sample analysis in these wavelengths.

Standard solution preparation

Accurately weighed amounts of standards of Car and Phe equivalent to 40.0 and 50.0 mg were transferred to separate volumetric flasks containing volume of 100.0 (solution 1) and 50.0 (solution 2) mL, respectively; 40.0 mg of Ace accurately weighed were transferred to volumetric flask of 100.0 mL containing 1.0 mL of the solution 1 and 2.0 mL of the solution 2, forming the standard solution. All volumes were completed with mobile phase. Final concentrations were 4.0, 20.0 and 400.0 mg L-1 for Car, Phe and Ace, respectively. Standard solution was filtered through a 0.45 μm millipore filter and diluted with mobile phase in order to obtain clear solutions.

Calibration curves

The following concentrations levels for: Car (3.2, 3.6, 4.0, 4.4 and 4.8 mg L-1); Phe (16.0, 18.0, 20.0, 22.0, 24.0 mg L-1) and Ace (320.0, 360.0, 400.0, 440.0, 480.0 mg L-1) were obtained from each standard solution, conveniently diluted with mobile phase in presence of the excipients. Each solution was injected in the chromatographic system (n=3) and mean values of peak areas were plotted against concentration. The curves were fitted by linear regression with least mean square method.

RESULTS AND DISCUSSION

Preliminary study

In order to investigate the method for drug analysis in pharmaceutical formulations, preliminary tests were performed to select optimal conditions. Parameters such as detection wavelength, ideal mobile phase and their proportions, optimum pH and standard solution concentration were exhaustively studied. Several binary or ternary eluents were tested using different proportions of solvent, such as acetonitrile, methanol and water. However, satisfactory results were achieved through the ion-pair reversed phase liquid chromatography (IRPLC) using sodium lauryl sulfate as ionic pair reagent. IRPLC was investigated as an alternative, based on the work described in the American Pharmacopeia for chlorpheniramine maleate analysis associated with phenylpropanolamine hydrochloride.7 In the present case, potassium phosphate monobasic and phosphoric acid were used for pH adjustment (≈ 4.10) and to promote ionic pair formation of the basic solutes with the counter ion. Methanol was used as an organic modifier and triethylamine was employed to reduce the tailing factor of the basic solutes, caused by the interaction between these compounds and the free silanol groups in the C18 surface column.

Figure 2 shows the chromatogram for standard mixture obtained through the optimized variables in accordance with the features described above. The baseline separation of standard mixture through isocratic mode within 5 min was achieved. The sample loop size was set at 50 μL in order to optimize the Car signal, which was in a concentration much smaller than Ace in the sample. Mobile phase flow was adjusted at 1.0 mL min-1 in order to maintain pressure within the acceptable limit of the chromatographic system.


Table 1 shows analytical parameters such as resolution (R), efficiency (N), asymmetry (A/B), and relative retention (α) obtained for the optimal conditions.

Validation procedures

After adjusting the chromatography conditions, some validation parameters for CP1 and CP2, such as selectivity, linearity, precision, limit of detection (LOD), limit of quantification (LOQ), accuracy and robustness, were determined, as Resolution ANVISA RE nº 899, of 29/05/2003.19

Selectivity and linearity

Method selectivity was assessed by the peak purity test (comparison between analyte peak and auto threshold in the purity plot) using diode array detector. The analyte chromatographic peak was not found to be attributable to more than one component.19,20

Linearity was evaluated taking into account the correlation coefficient (r). The correlation coefficient equal to or higher than 0.99 is considered evidence of ideal data fitting to line regression performed through least-square treatment.19 In order to evaluate lack of fit of the regression, Shapiro-Wilk Normality Test was performed for the residues.21 As the p-value calculated was higher than 0.05, the residue distribution is considered normal and the model is linear within the range evaluated (Table 2).

Precision, limit of detection (LOD) and limit of quantification (LOQ)

Precision can be determined through the estimate of the relative standard deviation (RSD).19 The precision in the validation of this optimized method was performed at two levels: repeatability and intermediate precision.

Repeatability (n=6) in sample area was carried out for 100.0% of the test concentration. In the present case, concentrations at 4.0, 20.0 and 400.0 mg L-1 for Car, Phe and Ace, respectively were used. Intermediate precision (n=6) was performed on different days. All results presented acceptable precision values (not exceeding 5.00%)19 as shown in Table 3.

LOD and LOQ were calculated by means of the standard deviation ratio of the intercept of three calibration curves obtained from linearity by means of the slopes of the respective curves multiplied by 3 and 10, respectively.19 LOD and LOQ obtained presented acceptable values for sample analysis as presented in Table 3.

Accuracy

Accuracy, in the present case, was calculated as the percentage of recovery by the assay of the known added amount of analyte in the sample.19,20 Thus, recovery tests were performed by adding known amounts of standard in the sample at five levels of concentrations for each drug, as shown in Table 5. For accuracy test, mean recovery percentage (R%) was 100.0 ± 2.0% and single R% concentration was 100.0 ± 5.0% (Table 4). The results obtained show that the method presents acceptable accuracy.

Robustness

The robustness was evaluated by intentional minor modifications in the chromatographic conditions in the proposed methodology.19 Within this context, the parameters selected to evaluate robustness were: mobile phase, flow rate and pH. Table 6 shows the experiments performed for robustness evaluation. It is important to remember that for commercial product 1 the maximum flow rate was set at 1.0 ml min-1 in order to maintain pressure lower than 3000 psi. All parameters were performed in six replicates. For the robustness test, the recovery achieved remained within the interval of 100.0 ± 5.0% as shown in Table 5. Therefore, little variations in the chromatographic parameters such as mobile phase, flow rate and pH were found to be acceptable values in relation to the reference value.

Quantitative determination in pharmaceutical preparations purchased from local pharmacies

After evaluating some validation parameters, the optimized method was applied to the sample analysis obtaining 19.9 mg (± 7.1 x10-2%) of Phe and 396,1 mg (± 4.0 x10-3%) of Ace for CP1 and 3,9 mg (± 1.8 x 10-1%) of Car and 402,4 mg (± 9.0 x 10-2%) of Ace for CP2 as results. Figure 3 shows the chromatograms obtained to samples analyzed.


CONCLUSIONS

The simultaneous separation of Ace, Phe and Car by isocratic ion-pair reversed phase liquid chromatography has been achieved. All validation parameters of the method optimized have obeyed the variation limits permitted. Therefore, the validated method can be useful for quality assurance in the pharmaceutical industry of these preparations, presenting a simple mobile phase system, short analysis time, and simple step of sample preparation as advantages in comparison with the methods described in the literature.

ACKNOWLEDGMENTS

The authors wish to acknowledge the Medquímica Indústria Farmacêutica Ltda, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES), Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq - 476386/2007-1 and 300593/2008-2) and Fundação de Amparo à Pesquisa do Estado de Minas Gerais of Brazil (FAPEMIG - CEX-APQ 1906-5.02-07 and CEX-APQ 01837/08) for fellowships and financial support.

Recebido em 30/9/08; aceito em 27/3/09; publicado na web em 10/8/09

  • 1. Korolkovas, A.: França, F. F. A. C.; Dicionário Terapêutico Guanabara, 15th ed., Guanabara Koogan S.A.: Rio de Janeiro, 2008.
  • 2
    Brazilian Pharmacopeia, 3rd ed., Andrei: São Paulo, 1977.
  • 3
    Brazilian Pharmacopeia, 4th ed., Atheneu: São Paulo, 1988.
  • 4. Marin, A.; Barbas, C.; J. Pharm. Biomed. Anal 2004, 35, 769.
  • 5. Marchesini, A. F.; Williner, M. R.; Mantovani, V. E.; Robles, J. C.; Goicoechea, H. C.; J. Pharm. Biomed. Anal. 2003, 31, 39.
  • 6. Okamoto, H.; Nakajima, T.; Ito, Y.; Aketo, T.; Shimada, K.; Yamato, S.; J. Pharm. Biomed. Anal. 2005, 37, 517.
  • 7. United States Pharmacopeia, 29th ed., United States Pharmacopeial Convention: Rockville, 2005.
  • 8. Marín, A.; García, E.; García, A.; Barbas, C.; J. Pharm. Biomed. Anal. 2002, 29, 701.
  • 9. Ravisankar, S.; Vasudevan, M.; Gandhimathi, M.; Suresh B.; Talanta 1998, 46, 1577.
  • 10. Marín, A.; Espada, A.; Vidal, P.; Barbas, C.; Anal. Chem. 2005, 77, 471.
  • 11. Gil-Agustí, M.; Garcia-Alvarez-Coque, M. C.; Esteve-Romero, J.; Anal. Chim. Acta 2000, 421, 45.
  • 12. Qi, M.; Wang, P.; Chen, J.; Chromatographia 2004, 60, 105.
  • 13. Erk, N.; Kartal, M.; l Fármaco 1998, 53, 617.
  • 14. Lau, O.; Mok, C.; J. Chromatogr., A 1995, 693, 45.
  • 15. García, A.; Rupérez, F. J.; Marín, A.; Maza, A. D. L.; Barbas, C.; J. Chromatogr., B 2003, 785, 237.
  • 16. Olmo, B.; García, A.; Marín, A.; Barbas, C.; J. Chromatogr., B 2005, 817, 159.
  • 17. Gumbhir, K.; Mason, W. D.; J. Pharm. Biomed. Anal. 1996, 14, 623.
  • 18. Shervington, L. A.; Sakhnini, N.; J. Pharm. Biomed. Anal. 2000, 24, 43.
  • 19
    Agência Nacional de Vigilância Sanitária (ANVISA); Resolução RE nº 899, de 29/05/2003.
  • 20
    International Conference Harmonisation (ICH); Validation of Analytical Procedures: Methodology, Q2B (CPMP/ICH/281/95), 1995.
  • 21. Montgomery, D. C.; Design and Analysis of Experiments, 6th ed., Wiley, 2005.
  • *
    e-mail:
  • Publication Dates

    • Publication in this collection
      22 Oct 2009
    • Date of issue
      2009

    History

    • Received
      30 Sept 2008
    • Accepted
      27 Mar 2009
    Sociedade Brasileira de Química Secretaria Executiva, Av. Prof. Lineu Prestes, 748 - bloco 3 - Superior, 05508-000 São Paulo SP - Brazil, C.P. 26.037 - 05599-970, Tel.: +55 11 3032.2299, Fax: +55 11 3814.3602 - São Paulo - SP - Brazil
    E-mail: quimicanova@sbq.org.br