A shortcut in phage screening technique

Abstract

A simple modification of the traditional Benton & Davis technique for phage screening is presented that avoids the tedious sample dilutions of putative spots/phages towards the second screening. With the use of a sole agar plate and nylon filter, the modification distinguishes a true positive recombinant from a false positive, with high probability of success.

phage screening; shortcut for Benton & Davis technique; single agar-plate


GENETICS OF MICROORGANISMS

SHORT COMMUNICATION

A shortcut in phage screening technique

Alexandre de AndradeI, II, * * These authors contributed equally to this work. ; Paula Rezende TeixeiraI, II, * * These authors contributed equally to this work. ; Fábio SivieroI, II; Roberto Vicente SantelliI

IUniversidade de São Paulo, Instituto de Química, Departamento de Bioquímica, São Paulo, SP, Brazil

IIUniversidade de São Paulo, Instituto de Ciências Biomédicas, Departamento de Biologia Celular e do Desenvolvimento, São Paulo, SP, Brazil

Correspondence Correspondence to Paula Rezende Teixeira Universidade de São Paulo, Instituto de Ciências Biomédicas, Departamento de Biologia Celular e do Desenvolvimento Avenida Lineu Prestes 1524 05508-900 São Paulo, SP, Brazil E-mail: paularez@usp.br

ABSTRACT

A simple modification of the traditional Benton & Davis technique for phage screening is presented that avoids the tedious sample dilutions of putative spots/phages towards the second screening. With the use of a sole agar plate and nylon filter, the modification distinguishes a true positive recombinant from a false positive, with high probability of success.

Key words: phage screening, shortcut for Benton & Davis technique, single agar-plate/nylon filter.

We have been working with phages for a long time, and a simplified CsCl protocol for lambda DNA purification was recently proposed by us. It avoids the enzymatic step, as well as the need for preliminary phage titration. This modification, requiring less steps and fewer solutions to prepare, produces a DNA suitable for further manipulation like digestion, ligation, labelling, subcloning, etc. (Santelli and Navarro-Cattapan, 2000). Now we are proposing a shortcut for the Benton & Davis technique (Benton and Davis, 1977). The screening of recombinant phages by this traditional technique is extremely efficient, but the confirmation of true positives in the second round frequently results in some false positives. This implies a waste of time and material. To diminish the frequency of these false recombinants, we conceived a modification of the original technique (Sambrook and Russell, 2001). This new approach has allowed us to distinguish, with great accuracy, a true positive spot from a false one, using a single agar-plate/nylon filter for a previously selected collection of potential positive phages (spots).

The technique consist of exposing the nylon filters to a PhosphorImager system (Storm, Molecular Dynamics) after the hybridization of the first screening and printing the results. Then, the image is printed to a transparency sheet. This makes the superposition of the transparency against the filters and agar plates easier, allowing a precise co-localization of the chosen spots on the agar plates. With the help of the wide side (diameter of approximately 4 mm) of a Pasteur pipette, the agar plugs corresponding to each spot are transferred to tubes containing 0.5 mL of lambda buffer (Tris pH 7.5 10 mM - MgCl2 10 mM) and a drop of chloroform. After approximately 2 h, 5 mL of each suspension are placed onto a fresh agarose upper layer made with competent bacteria (DL 538 E. coli strain) as usual. At least eight samples can be positioned on a sole agar plate. The next day, the plate with several individual large lysis plaques is covered with a nylon filter, and DNA transfer is performed according to the traditional procedure, devised by the above cited authors (Benton and Davis, 1977). Finally, the filter is hybridized using the same probe solution used in the original screening.

After many experiments using this technique, we observed that positive phages develop darker spots than the control (a plug removed from another region of the same plate). Experiment duplicates confirmed the reproducibility of the method. The most frequent result that distinguishes a positive recombinant from a false one is the presence of some dark mini-spots over the gray background area, resembling the labeling of an isolated phage plate (see Figure 1).


We have applied this simple modification with great success to the isolation of phages from a genomic library of the insect Rhynchosciara americana, as compared to the positivity estimate by the traditional methods (Table 1). This modification is less tedious than the plating of several dilutions of putative samples normally used in the second screening round. Another obvious advantage is that it avoids the waste of several expensive nylon filters.

Acknowledgments

This work was supported by FAPESP.

Received: October 8, 2003; Accepted: August 16, 2004.

Associate Editor: Sérgio Olavo Pinto da Costa

  • Benton WD and Davis RW (1977) Screening lambda gt recombinant clones by hybridization to single plaques in situ Science 196:180-182.
  • Sambrook J and Russell DW (2001) Molecular Cloning: A Laboratory Manual. 3nd ed. Cold Spring Harbor Laboratory Press, Cold Spring Harbor, New York, pp 2.90-2.100.
  • Santelli RV and Navarro-Cattapan LD (2000). A simplified CsCl protocol for lambda DNA purification: No enzymatic treatment/one phenol extraction. Genetics and Molecular Biology 23:65-66.
  • Correspondence to
    Paula Rezende Teixeira
    Universidade de São Paulo, Instituto de Ciências Biomédicas, Departamento de Biologia Celular e do Desenvolvimento
    Avenida Lineu Prestes 1524
    05508-900 São Paulo, SP, Brazil
    E-mail:
  • *
    These authors contributed equally to this work.
  • Publication Dates

    • Publication in this collection
      08 Sept 2005
    • Date of issue
      Mar 2005

    History

    • Received
      08 Oct 2003
    • Accepted
      16 Aug 2004
    Sociedade Brasileira de Genética Rua Cap. Adelmio Norberto da Silva, 736, 14025-670 Ribeirão Preto SP Brazil, Tel.: (55 16) 3911-4130 / Fax.: (55 16) 3621-3552 - Ribeirão Preto - SP - Brazil
    E-mail: editor@gmb.org.br