Hardness correlation length in a self-compacting concrete

Comprimento de correlação da dureza em um concreto autoadensável

ABSTRACT:

This paper presents an experimental study of spatial variation of hardness or indentation strength of a self-compacting concrete. With the pourpose of validation, the comparison between the used methodologies with the values obtained by numerical simulation is presented. The correlation length (Lcor) obtained on the semivariogram using a Gaussian model is similar to the numerically simulated value, especially when the distance between the measurements is less than the sought Lcor. Using sclerometry, it was possible to infer that to find the value of concrete correlation length it is necessary to measure nearby points, at ca. 2cm apart. With this scheme, the value of Lcor found is close to the obtained using macro-indentation, a more complex and time-consuming procedure. Finally, for the studied self-compacting concrete, the correlation length is equivalent to a value between 5 to 6 times the maximum aggregate size.

Keywords:
spatial distribution; self-compacting concrete; hardness; indentation

IBRACON - Instituto Brasileiro do Concreto Instituto Brasileiro do Concreto (IBRACON), Av. Queiroz Filho, nº 1700 sala 407/408 Torre D, Villa Lobos Office Park, CEP 05319-000, São Paulo, SP - Brasil, Tel. (55 11) 3735-0202, Fax: (55 11) 3733-2190 - São Paulo - SP - Brazil