Two-way ribbed flat slabs with shafts

The position of pipes and hoses for several installations still deserves special attention from designers mainly when the failure mode can be modified due to changes in behavior. This work compares experimental results of six two-way reinforced concrete ribbed flat slabs with rectangular holes close to the column and without shear reinforcement with the estimates obtained from codes ACI 318 and NBR 6118 equations. All slabs were casted and tested in the Civil Engineering Laboratory of UFPA and had dimensions of 1.800 mm x 1.800 mm x 150 mm and were submitted to central loading applied through 120 mm side square steel plates simulating the columns. EPS was used as inert material and the ribs were spaced 250 mm with 130 mm height and 75 mm average wide. The results showed that the codes' shear equations estimates agree when the ribs are considered as beam and also for punching shear, but trend to be safer when the slabs present two shafts.

flat slab; ribbed slab; shaft; holes; shear; punching


IBRACON - Instituto Brasileiro do Concreto Instituto Brasileiro do Concreto (IBRACON), Av. Queiroz Filho, nº 1700 sala 407/408 Torre D, Villa Lobos Office Park, CEP 05319-000, São Paulo, SP - Brasil, Tel. (55 11) 3735-0202, Fax: (55 11) 3733-2190 - São Paulo - SP - Brazil