Acessibilidade / Reportar erro

Central sterile services department: screening of automated cleaning in liposuction cannulae

Central de material y esterilización: seguimento de limpeza automatizado en las cánulas de liposucción

ABSTRACT

Objective:

To evaluate the effectiveness of automated cleaning of 4 mm liposuction cannulas using ultrasonic washer machine, screening for dirt using a cannulate microscope device and the screening of viable strains of Staphylococcus aureus, with microbiological analysis.

Method:

Experimental study with 14 units of 4 mm liposuction cannulas performed at the Central Sterile Services Department and at the Microbiology Laboratory of a Hospital Complex, located in Porto Alegre, RS, Brazil, from October 2018 to April 2019.

Results:

Of the 14 liposuction cannulas that constituted the sample, 42.9% remained dirty despite automated cleaning, and all of them showed recovery of viable microrganisms in the microbiological laboratory.

Conclusion:

The study showed that it is not possible to ensure the cleaning efficacy of automated cleaning of 4 mm liposuction cannulas, especially due to the conformation of the material with internal spaces with accumulation of dirt.

Keywords:
Surgical instruments; Sterilization; Perioperative nursing

Universidade Federal do Rio Grande do Sul. Escola de Enfermagem Rua São Manoel, 963 -Campus da Saúde , 90.620-110 - Porto Alegre - RS - Brasil, Fone: (55 51) 3308-5242 / Fax: (55 51) 3308-5436 - Porto Alegre - RS - Brazil
E-mail: revista@enf.ufrgs.br