ABSTRACT
Objective:
To evaluate the effectiveness of automated cleaning of 4 mm liposuction cannulas using ultrasonic washer machine, screening for dirt using a cannulate microscope device and the screening of viable strains of Staphylococcus aureus, with microbiological analysis.
Method:
Experimental study with 14 units of 4 mm liposuction cannulas performed at the Central Sterile Services Department and at the Microbiology Laboratory of a Hospital Complex, located in Porto Alegre, RS, Brazil, from October 2018 to April 2019.
Results:
Of the 14 liposuction cannulas that constituted the sample, 42.9% remained dirty despite automated cleaning, and all of them showed recovery of viable microrganisms in the microbiological laboratory.
Conclusion:
The study showed that it is not possible to ensure the cleaning efficacy of automated cleaning of 4 mm liposuction cannulas, especially due to the conformation of the material with internal spaces with accumulation of dirt.
Keywords:
Surgical instruments; Sterilization; Perioperative nursing