Acessibilidade / Reportar erro
Revista Brasileira de Terapia Intensiva, Volume: 26, Número: 1, Publicado: 2014
  • A equipe da UTI está satisfeita com o prontuário eletrônico do paciente? Um estudo transversal Artigos Originais

    Fumis, Renata Rego Lins; Costa, Eduardo Leite Vieira; Martins, Paulo Sergio; Pizzo, Vladimir; Souza, Ivens Augusto; Schettino, Guilherme de Paula Pinto

    Resumo em Português:

    Objetivo: Avaliar a satisfação da equipe da unidade de terapia intensiva com o prontuário eletrônico do paciente e comparar a relevância do conceito de registro eletrônico de ordens médicas entre os profissionais de saúde da unidade de terapia intensiva. Métodos: Estudo transversal de levantamento para avaliar a satisfação da equipe da unidade de terapia intensiva com o prontuário eletrônico do paciente em uma unidade de terapia intensiva clínica e cirúrgica para pacientes adultos com 30 leitos, utilizando um questionário de autopreenchimento. As questões utilizadas para graduar os níveis de satisfação foram respondidas segundo uma escala numérica, que variava de 1 (baixo grau de satisfação) a 10 pontos (elevado grau de satisfação). Resultados: As pessoas que responderam ao questionário (n=250) eram, em sua maioria, do gênero feminino (66%) com idades entre 30 e 35 anos (69%). O grau geral de satisfação com o prontuário eletrônico do paciente foi de 5,74±2,14 pontos. O grau de satisfação foi mais baixo entre os médicos (n=42) do que entre enfermeiros, técnicos de enfermagem, terapeutas respiratórios, farmacêuticos clínicos e nutricionistas (4,62±1,79 em comparação com 5,97±2,14; p<0,001); o grau de satisfação decresceu com a idade (p<0,001). Os médicos tiveram níveis mais baixos de satisfação com relação ao potencial do sistema de registro eletrônico de ordens médicas de melhorar a segurança do paciente (5,45±2,20 em comparação com 8,09±2,21; p<0,001) e facilidade de uso do sistema de registro eletrônico de ordens médicas (3,83±1,88 em comparação com 6,44±2,31; p<0,001). As características com associação independente com satisfação foram sistema amigável ao usuário, precisão, capacidade de fornecer informação clara, e tempo de resposta rápido. Conclusão: Depois de 6 meses da implantação do sistema, os profissionais de saúde estavam satisfeitos, embora não totalmente, com o prontuário eletrônico do paciente. O grau geral de satisfação entre os usuários do prontuário eletrônico do paciente foi mais baixo entre os médicos do que entre os demais profissionais de saúde. Os fatores associados com o grau de satisfação incluíram a crença de que a digitalização reduziria a carga de trabalho e contribuiria para qualidade da unidade de terapia intensiva com um sistema amigável e preciso para o usuário e que a digitalização proporcionaria informações concisas dentro de um período de tempo razoável.

    Resumo em Inglês:

    Objective: To evaluate the satisfaction of the intensive care unit staff with a computerized physician order entry and to compare the concept of the computerized physician order entry relevance among intensive care unit healthcare workers. Methods: We performed a cross-sectional survey to assess the satisfaction of the intensive care unit staff with the computerized physician order entry in a 30-bed medical/surgical adult intensive care unit using a self-administered questionnaire. The questions used for grading satisfaction levels were answered according to a numerical scale that ranged from 1 point (low satisfaction) to 10 points (high satisfaction). Results: The majority of the respondents (n=250) were female (66%) between the ages of 30 and 35 years of age (69%). The overall satisfaction with the computerized physician order entry scored 5.74±2.14 points. The satisfaction was lower among physicians (n=42) than among nurses, nurse technicians, respiratory therapists, clinical pharmacists and diet specialists (4.62±1.79 versus 5.97±2.14, p<0.001); satisfaction decreased with age (p<0.001). Physicians scored lower concerning the potential of the computerized physician order entry for improving patient safety (5.45±2.20 versus 8.09±2.21, p<0.001) and the ease of using the computerized physician order entry (3.83±1.88 versus 6.44±2.31, p<0.001). The characteristics independently associated with satisfaction were the system's user-friendliness, accuracy, capacity to provide clear information, and fast response time. Conclusion: Six months after its implementation, healthcare workers were satisfied, albeit not entirely, with the computerized physician order entry. The overall users' satisfaction with computerized physician order entry was lower among physicians compared to other healthcare professionals. The factors associated with satisfaction included the belief that digitalization decreased the workload and contributed to the intensive care unit quality with a user-friendly and accurate system and that digitalization provided concise information within a reasonable time frame.
  • Impacto de um programa de educação continuada na qualidade assistencial oferecida pela fisioterapia em terapia intensiva Artigos Originais

    Pinto, Walkyria Araújo Macedo; Rossetti, Heloisa Baccaro; Araújo, Abigail; Spósito Júnior, José Jonas; Salomão, Hellen; Mattos, Simone Siqueira; Rabelo, Melina Vieira; Machado, Flávia Ribeiro

    Resumo em Português:

    Objetivo: Avaliar o papel de indicadores de qualidade e registro de eventos adversos na qualidade assistencial da fisioterapia em terapia intensiva, bem como o impacto da implantação de protocolos de cuidado e treinamento profissional no processo de melhoria da qualidade. Métodos: Estudo prospectivo antes-depois para avaliar 15 indicadores de qualidade assistencial. Dados basais a respeito de adesão e eventos adversos foram coletados antes e após a implantação de protocolos de tratamento e treinamento da equipe. Resultados: Foram avaliados 89 pacientes, sendo 48 admitidos no período préintervenção e 41 no período pós-intervenção, com um total de 1.246 e 1.191 observações, respectivamente. Entre os indicadores relacionados à população global, houve melhora significativa no controle radiográfico, passagem de plantão, visita multiprofissional, assim como na adesão a essas decisões. Os indicadores relacionados com a população sob ventilação mecânica, obtidos por observação direta no leito, mostraram melhora significativa na adesão ao volume corrente de 6 a 8mL/kg, pressão platô <30cmH2O, adequação dos alarmes da ventilação mecânica, controle de umidificação da ventilação mecânica, troca dos equipos de umidificação, e posicionamento do tubo orotraqueal. Entre os indicadores de ventilação mecânica coletados por meio de registros da fisioterapia, ocorreu melhora significativa da adesão ao registro do volume corrente predito e ao registro da pressão do balonete. Houve redução significativa no número de eventos adversos. Não houve impacto na mortalidade na unidade de terapia intensiva, no tempo de internação, tempo de ventilação mecânica e no tempo livre da ventilação mecânica. Conclusão: É possível medir a qualidade do cuidado fisioterapêutico utilizando indicadores de controle de qualidade. A implantação de protocolos de cuidado e treinamento dos profissionais pode melhorar o desempenho da equipe.

    Resumo em Inglês:

    Objective: To evaluate the role of quality indicators and adverse events registering in the quality assessment of intensive care physiotherapy and to evaluate the impact of implementing protocolized care and professional training in the quality improvement process. Methods: A prospective before-after study was designed to assess 15 indicators of the quality of care. Baseline compliance and adverse events were collected before and after the implementation of treatment protocols and staff training. Results: Eighty-nine patients admitted, being 48 in the pre-intervention period and 41 in the post-intervention period with a total of 1246 and 1191 observations respectively. Among the indicators related to the global population, there was a significant improvement in chest x-ray control, multidisciplinary rounds and shift changes as well as in compliance with these decisions. Indicators related to the population under mechanical ventilation, obtained by direct observation at bedside, showed a significant improvement in the compliance with the tidal volume of 6-8mL/Kg, plateau pressure <30cmH2O, adequate mechanical ventilation alarm setting, mechanical ventilation humidification control, adequate humidification line exchange and orotracheal tube position. Among the mechanical ventilation indicators collected through the physiotherapy records, there was significantly improved compliance with the predicted tidal volume registry and cuff pressure registry. There was a significant reduction in the number of adverse events. There was no impact on intensive care unit mortality, length of stay, duration of mechanical ventilation and ventilator-free days. Conclusion: It is possible to measure the quality of physiotherapy care using indicators of quality control. The implementation of care protocols and training of the professionals can improve team performance.
  • Incremento da depuração renal em pacientes gravemente enfermos: incidência, fatores associados e efeitos no tratamento com vancomicina Artigos Originais

    Campassi, María Luz; Gonzalez, María Cecilia; Masevicius, Fabio Daniel; Vazquez, Alejandro Risso; Moseinco, Miriam; Navarro, Noelia Cintia; Previgliano, Luciana; Rubatto, Nahuel Paolo; Benites, Martín Hernán; Estenssoro, Elisa; Dubin, Arnaldo

    Resumo em Português:

    Objetivo: Foi descrito um incremento da depuração renal em alguns grupos de pacientes gravemente enfermos, o qual pode induzir à eliminação de concentrações de fármacos por filtração glomerular aquém do ideal, principalmente no caso de antibióticos. Sua ocorrência e os fatores determinantes têm sido pouco estudados. Nossos objetivos foram determinar a incidência e os fatores associados ao incremento da depuração renal, bem como seus efeitos nas concentrações e na posologia de vancomicina em uma série de pacientes em unidade de terapia intensiva. Métodos: Estudamos, de forma prospectiva, 363 pacientes admitidos durante 1 ano em uma unidade de terapia intensiva clínico-cirúrgica. Foram excluídos pacientes que tivessem nível de creatinina sérica >1,3mg/dL. A depuração de creatinina foi calculada a partir da coleta de urina de 24 horas. Os pacientes foram agrupados segundo a presença de incremento da depuração renal (depuração de creatinina >120mL/min/1,73m2), e os possíveis fatores de risco foram analisados por meio de análise bivariada e logística. Em pacientes tratados com vancomicina, foram registradas a posologia e as concentrações plasmáticas. Resultados: O incremento da depuração renal esteve presente em 103 pacientes (28%), os quais eram mais jovens (48±15 versus 65±17 anos; p<0,0001), tinham mais frequentemente admissões obstétricas (16 versus 7%; p=0,0006) e por trauma (10 versus 3%; p=0,016), e menos comorbidades. Os únicos determinantes independentes para o desenvolvimento de incremento da depuração renal foram idade (OR=0,95; IC95%=0,93-0,96; p<0,0001;) e ausência de diabetes (OR 0,34; IC95% 0,12-0,92; p=0,03). Doze dos 46 pacientes que receberam vancomicina tinham incremento da depuração renal e, apesar das doses elevadas, tinham concentrações plasmáticas de vancomicina mais baixas. Conclusões: Nessa coorte de pacientes gravemente enfermos, foi frequente o achado de incremento da depuração renal. Idade e ausência de diabetes foram os únicos determinantes independentes. Assim, pacientes jovens e previamente saudáveis podem necessitar de doses mais elevadas de vancomicina.

    Resumo em Inglês:

    Objective: An augmented renal clearance has been described in some groups of critically ill patients, and it might induce sub-optimal concentrations of drugs eliminated by glomerular filtration, mainly antibiotics. Studies on its occurrence and determinants are lacking. Our goals were to determine the incidence and associated factors of augmented renal clearance and the effects on vancomycin concentrations and dosing in a series of intensive care unit patients. Methods: We prospectively studied 363 patients admitted during 1 year to a clinical-surgical intensive care unit. Patients with serum creatinine >1.3mg/dL were excluded. Creatinine clearance was calculated from a 24-hour urine collection. Patients were grouped according to the presence of augmented renal clearance (creatinine clearance >120mL/min/1.73m2), and possible risk factors were analyzed with bivariate and logistic regression analysis. In patients treated with vancomycin, dosage and plasma concentrations were registered. Results: Augmented renal clearance was present in 103 patients (28%); they were younger (48±15 versus 65±17 years, p<0.0001), had more frequent obstetric (16 versus 7%, p=0.0006) and trauma admissions (10 versus 3%, p=0.016) and fewer comorbidities. The only independent determinants for the development of augmented renal clearance were age (OR 0.95; p<0.0001; 95%CI 0.93-0.96) and absence of diabetes (OR 0.34; p=0.03; 95%CI 0.12-0.92). Twelve of the 46 patients who received vancomycin had augmented renal clearance and despite higher doses, had lower concentrations. Conclusions: In this cohort of critically ill patients, augmented renal clearance was a common finding. Age and absence of diabetes were the only independent determinants. Therefore, younger and previously healthy patients might require larger vancomycin dosing.
  • Perfil de doadores efetivos do serviço de procura de órgãos e tecidos Artigos Originais

    Rodrigues, Simey de Lima Lopes; Ferraz Neto, Jose Ben-Hur de Escobar; Sardinha, Luiz Antonio da Costa; Araujo, Sebastião; Zambelli, Helder Jose Lessa; Boin, Ilka de Fátima Santana Ferreira; Athayde, Maria Valeria de Omena; Montone, Eliete Bombarda Bachega; Panunto, Marcia Raquel

    Resumo em Português:

    Objetivo: Caracterizar o perfil dos doadores efetivos de órgãos e tecidos além de conhecer quais órgãos e tecidos foram doados para transplantes. Métodos: Estudo quantitativo, descritivo, exploratório e retrospectivo, analisando-se os dados de prontuários de 305 doadores, entre janeiro de 2006 a dezembro de 2010, os quais foram submetidos à análise descritiva com confecção de tabelas de frequência, medidas de posição (média, mínimo e máximo) e dispersão (desvio-padrão) para os dados de caráter social e clínico. Resultados: Houve predomínio de indivíduos brancos (72%), do gênero masculino (55%), idade entre 41 e 60 anos (44%), sendo a principal causa de morte encefálica o acidente vascular encefálico (55%). Quanto aos antecedentes, 31% foram classificados na categoria de sobrepeso, seguidos de hipertensão arterial sistêmica (27%) e o diabetes mellitus encontrado em apenas 4,3% dos doadores. O uso de drogas vasoativas esteve presente em 92,7% dos doadores, e a principal droga utilizada foi a noradrenalina (81,6%). A hiperglicemia e a hipernatremia foram encontradas em 78% e em 71% dos doadores, respectivamente. Conclusão: Foram encontradas importantes alterações hemodinâmicas, e os resultados mostram o uso de drogas vasoativas como a principal estratégia para seu controle. Ademais, a maioria dos doadores apresentou hiperglicemia e hipernatremia, achados frequentes no quadro de morte encefálica, e que, por sua persistência, sugerem manutenção inadequada do doador de órgãos.

    Resumo em Inglês:

    Objective: To characterize the profile of effective organ and tissue donors and to understand which organs and tissues were donated for transplantation. Methods: This was a quantitative, descriptive, exploratory, retrospective study that analyzed clinical data from 305 donors between January 2006 to December 2010. The data were then analyzed using descriptive analyses, generating frequency tables, measures of position (mean, minimum and maximum) and measures of dispersion (standard deviation) for data that was social and clinical in nature. Results: There was an overall predominance of white (72%) and male (55%) individuals between the ages of 41 and 60 years (44%). The primary cause of brain death was cerebrovascular accident (55%). In the patient history, 31% of the patients were classified as overweight, 27% as hypertensive and only 4.3% as having diabetes mellitus. Vasoactive drugs were used in 92.7% of the donors, and the main drug of choice was noradrenaline (81.6%). Hyperglycemia and hypernatremia were diagnosed in 78% and 71% of the donors, respectively. Conclusion: Significant hemodynamic changes were found, and the results indicate that the use of vasoactive drugs was the main strategy used to control these changes. Furthermore, most donors presented with hyperglycemia and hypernatremia, which were frequently reported in association with brain death. The persistent nature of these findings suggests that the organ donors were inadequately maintained.
  • Tempo estímulo-resposta da equipe de saúde aos alarmes de monitorização na terapia intensiva: implicações para a segurança do paciente grave Artigos Originais

    Bridi, Adriana Carla; Silva, Roberto Carlos Lyra da; Farias, Carolina Correa Pinto de; Franco, Andrezza Serpa; Santos, Viviane de Lima Quintas dos

    Resumo em Português:

    Objetivo: Definir as características e mensurar o tempo estímulo-resposta da equipe de saúde aos alarmes de monitorização na terapia intensiva. Métodos: Estudo de abordagem quantitativa, observacional, descritivo, desenvolvido na unidade coronariana de um hospital público de cardiologia no Rio de Janeiro (RJ). Os dados foram extraídos de informações referentes aos pacientes, monitorização utilizada e da medição do tempo estímulo-resposta da equipe aos alarmes dos monitores multiparamétricos por observação de campo não participativa. Resultados: Acompanhamos 88 pacientes (49 no serviço diurno e 39 no serviço noturno). O número total de alarmes de monitorização foi de 227 nas 40 horas de observação (20 horas no serviço diurno e 20 horas no serviço noturno), 106 alarmes no serviço diurno e 121 no serviço noturno, numa média de 5,7 alarmes/hora. Foram observados 145 alarmes sem resposta da equipe, 68 (64,15%) alarmes no serviço diurno e 77 (63,64%) no serviço noturno. Demonstramos que mais de 60% dos alarmes excederam o tempo-resposta de 10 minutos, considerados alarmes sem resposta. Obtivemos uma mediana de temporesposta dos alarmes atendidos de 4 minutos e 54 segundos no serviço diurno e 4 minutos e 55 segundos no serviço noturno. A monitorização da respiração encontrava-se ativada em apenas 9 pacientes (23,07%) no serviço noturno. Em relação à habilitação dos alarmes dessas variáveis, o alarme de arritmia estava habilitado em somente 10 (20,40%) dos pacientes no serviço diurno e o alarme da respiração em 4 pacientes (44,44%) no serviço noturno. Conclusão: A programação e configuração de variáveis fisiológicas monitorizadas e parâmetros de alarmes na unidade foram inadequadas, houve retardo no tempo resposta e falta de resposta aos alarmes, sugerindo que alarmes relevantes podem ter sido ignorados pela equipe, comprometendo assim a segurança dos pacientes.

    Resumo em Inglês:

    Objective: To define the characteristics and measure the reaction time of a health care team monitoring alarms in the intensive care unit. Methods: A quantitative, observational, and descriptive study developed at the coronary care unit of a cardiology public hospital in Rio de Janeiro state (RJ). Data were obtained from the information collected on the patients, the monitoring used, and the measurement of the team's reaction time to the alarms of multi-parameter monitors during a non-participatory field observation. Results: Eighty-eight patients were followed (49 during the day shift and 39 during the night shift). During the 40 hours of observation (20 hours during the day shift and 20 hours during the night shift), the total number of monitoring alarms was 227, with 106 alarms during the day shift and 121 during the night shift, an average of 5.7 alarms/hour. In total, 145 alarms unanswered by the team were observed, with 68 occurring during the day shift (64.15%) and 77 during the night shift (63.64%). This study demonstrated that the reaction time was longer than 10 minutes in more than 60% of the alarms, which were considered as unanswered alarms. The median reaction time of the answered alarms was 4 minutes and 54 seconds during the day shift and 4 minutes and 55 seconds during the night shift. The respiration monitoring was activated in only nine patients (23.07%) during the night shift. Regarding the alarm quality of these variables, the arrhythmia alarm was qualified in only 10 (20.40%) of the day-shift patients and the respiration alarm in four night-shift patients (44.44%). Conclusion: The programming and configuration of the physiological variables monitored and the parameters of alarms in the intensive care unit were inadequate; there was a delay and lack of response to the alarms, suggesting that relevant alarms may have been ignored by the health care team, thus compromising the patient safety.
  • Aplicação de escores para estimar carga de trabalho de enfermagem em unidade de terapia intensiva pediátrica Artigos Originais

    Campagner, Andriza Oliveira Moschetta; Garcia, Pedro Celiny Ramos; Piva, Jefferson Pedro

    Resumo em Português:

    Objetivo: Avaliar o desempenho do Nursing Activities Score na unidade de terapia intensiva pediátrica, comparar os resultados do tempo de atividades de enfermagem obtidos com esse escore com o tempo obtido pelo o Simplified Therapeutic Intervention Scoring System, e associar tais índices à gravidade, morbidade e mortalidade. Métodos: Estudo de coorte prospectivo observacional e analítico realizado em uma unidade de terapia intensiva pediátrica geral do tipo III. A amostra foi constituída por todas as crianças com idade entre 29 dias e 12 anos completos, que foram hospitalizadas na unidade de terapia intensiva pediátrica no período entre agosto de 2008 a fevereiro de 2009. Resultados: Estudaram-se 545 admissões com 2.951 observações. O valor médio para todas as observações do Simplified Therapeutic Intervention Scoring System foi de 28,79±10,37 pontos (915±330 minutos) e do Nursing Activities Score foi de 55,67±11,82 pontos (802±161 minutos). Os minutos obtidos a partir da conversão do escore Simplified Therapeutic Intervention Scoring System foram superiores aos obtidos com a conversão da pontuação do Nursing Activities Score em todas as observações (p<0,001). Os dois índices apresentaram uma correlação significante, direta, positiva e moderada, com R=0,564. Conclusões: Observaram-se boa concordância entre os índices e boa capacidade de discriminação para mortalidade, com melhor ponto de corte de 16 horas/paciente de trabalho de enfermagem por dia.

    Resumo em Inglês:

    Objective: To assess the performance of the Nursing Activities Score in a pediatric intensive care unit, compare its scores expressed as time spent on nursing activities to the corresponding ones calculated using the Simplified Therapeutic Intervention Scoring System, and correlate the results obtained by both instruments with severity, morbidity and mortality. Methods: Prospective, observational, and analytical cohort study conducted at a type III general pediatric intensive care unit. The study participants were all the children aged 29 days to 12 years admitted to the investigated pediatric intensive care unit from August 2008 to February 2009. Results: A total of 545 patients were studied, which corresponded to 2,951 assessments. The average score of the Simplified Therapeutic Intervention Scoring System was 28.79±10.37 (915±330 minutes), and that of the Nursing Activities Score was 55.6±11.82 (802±161 minutes). The number of minutes that resulted from the conversion of the Simplified Therapeutic Intervention Scoring System score was higher compared to that resulting from the Nursing Activities Score for all the assessments (p<0.001). The correlation between the instruments was significant, direct, positive, and moderate (R=0.564). Conclusions: The agreement between the investigated instruments was satisfactory, and both instruments also exhibited satisfactory discrimination of mortality; for that purpose, the best cutoff point was 16 nursing hours/patient day.
  • Desempenho do Pediatric Index of Mortality 2 em unidade de cuidados intensivos pediátrica Artigos Originais

    Lima Netto, Antônio; Muniz, Virginia Maria; Zandonade, Eliana; Maciel, Ethel Leonor Noia; Bortolozzo, Rodrigo Nichio; Costa, Nélio Ferreira; Limongi, Rosane da Silva de Araujo

    Resumo em Português:

    Objetivo: Avaliar a discriminação e a calibração do Pediatric Index of Mortality 2 em pacientes de uma unidade de cuidados intensivos pediátrica. Métodos: Estudo de coorte contemporânea realizado no período de novembro de 2005 a novembro de 2006. Os limites de idade foram 29 dias de vida e 18 anos. Excluídos aqueles com óbito em menos de 12 horas após admissão e readmissões. Para o desempenho do Pediatric Index of Mortality 2, foram aplicados o teste de Hosmer-Lemeshow, o índice padronizado de mortalidade standardized mortality ratio e área sob a curva ROC, intervalo de confiança de 95%. O nível de significância foi de 5%. Resultados: Foram estudadas 276 admissões de pacientes. A taxa de mortalidade foi de 14,13%, com eficiência de admissão de 0,88%. A mediana de idade foi de 42,22 meses, havendo predomínio do gênero masculino com 60,1%. O setor de emergência foi responsável por 48,91% das admissões. Tempo de permanência foi de 6,43±5,23 dias (média). As admissões clínicas corresponderam a 72,46% e associaram-se ao óbito (odds ratio: 2,9; intervalo de confiança de 95%: 1,09-7,74; p=0,017). O Pediatric Index of Mortality 2 apresentou calibração com qui-quadrado de 12,2686 (p=0,1396) no teste de Hosmer-Lemeshow, e índice padronizado de morte de 1,0. A discriminação relacionada à área abaixo da curva ROC foi de 0,778. Conclusão: O escore Pediatric Index of Mortality 2 apresentou desempenho satisfatório.

    Resumo em Inglês:

    Objective: To assess the discrimination and calibration of the Pediatric Index of Mortality 2 in patients admitted to a pediatric intensive care unit. Methods: The study was conducted with a contemporary cohort from November 2005 to November 2006. Patients aged 29 days to 18 years were included in the study. Patients who died within 12 hours of admission and cases of readmission were excluded from the study. The performance of the Pediatric Index of Mortality 2 was assessed by means of the Hosmer-Lemeshow goodness-of-fit test, the standardized mortality ratio and the area under receiver operating characteristic (ROC) curve with 95% confidence interval. The significance level was established as 5%. Results: A total of 276 admissions to the pediatric intensive care unit were included in the analysis. The mortality rate was 14.13%, and the efficiency of admission 0.88%. The median age of the sample was 42.22 months, and most participants were male (60.1%). Most admissions were referrals from the emergency department. The mean duration of stay in pediatric intensive care unit was 6.43±5.23 days. Approximately 72.46% of admissions were for clinical reasons and exhibited an association with the outcome death (odds ratio: 2.9; 95%CI: 1.09-7.74; p=0.017). Calibration of the Pediatric Index of Mortality 2 with the chi-square statistic was 12.2686 (p=0.1396) in the Hosmer-Lemeshow goodness-of-fit test, and the standardized mortality ratio was 1.0. The area under the ROC curve assessing model discrimination was 0.778. Conclusion: Pediatric Index of Mortality 2 exhibited satisfactory performance.
  • Fatores preditivos para falha de extubação e reintubação de recém-nascidos submetidos à ventilação pulmonar mecânica Artigos Originais

    Costa, Ana Cristina de Oliveira; Schettino, Renata de Carvalho; Ferreira, Sandra Clecêncio

    Resumo em Português:

    Objetivo: Identificar os fatores de risco para falha de extubação e reintubação em recém-nascidos submetidos à ventilação pulmonar mecânica, e determinar se parâmetros ventilatórios e dados gasométricos são fatores preditores desses eventos. Métodos: Estudo prospectivo, realizado no período entre maio a novembro de 2011, em uma unidade de terapia intensiva neonatal. Foram avaliados 176 recém-nascidos de ambos os gêneros, submetidos à ventilação pulmonar mecânica posterior à extubação. Considerou-se falha na extubação se o retorno à ventilação pulmonar mecânica ocorresse antes de 72 horas. A reintubação ocorreu quando, em algum momento após as 72 horas, os recém-nascidos necessitassem de ser reintubados. Resultados: Na análise univariada, idade gestacional <28 semanas, peso <1.000g e valores baixos de Apgar estiveram associados a falha de extubação e a reintubação. Já na análise multivariada, as variáveis que se mantiveram associadas à falha na extubação foram dias de ventilação mecânica, potencial hidrogeniônico e pressão parcial de oxigênio, e, para a reintubação, foram Apagar no 5º minuto e idade na extubação. Conclusão: Menores Apgar no 5º minuto, idade na extubação e tempo de ventilação mecânica, além da presença de distúrbios ácido-base e hiperóxia foram variáveis que apresentaram relação com os eventos analisados.

    Resumo em Inglês:

    Objective: To identify risk factors for extubation failure and reintubation in newborn infants subjected to mechanical ventilation and to establish whether ventilation parameters and blood gas analysis behave as predictors of those outcomes. Methods: Prospective study conducted at a neonatal intensive care unit from May to November 2011. A total of 176 infants of both genders subjected to mechanical ventilation were assessed after extubation. Extubation failure was defined as the need to resume mechanical ventilation within less than 72 hours. Reintubation was defined as the need to reintubate the infants any time after the first 72 hours. Results: Based on the univariate analysis, the variables gestational age <28 weeks, birth weight <1,000g and low Apgar scores were associated with extubation failure and reintubation. Based on the multivariate analysis, the variables length of mechanical ventilation (days), potential of hydrogen (pH) and partial pressure of oxygen (pO2) remained associated with extubation failure, and the five-minute Apgar score and age at extubation were associated with reintubation. Conclusion: Low five-minute Apgar scores, age at extubation, length of mechanical ventilation, acid-base disorders and hyperoxia exhibited associations with the investigated outcomes of extubation failure and reintubation.
  • Disponibilidade de assistência fisioterapêutica em unidades de terapia intensiva neonatal na cidade de São Paulo Artigos Originais

    Liberali, Joyce; Davidson, Josy; Santos, Amelia Miyashiro Nunes dos

    Resumo em Português:

    Objetivo: Descrever as características da assistência fisioterapêutica prestada a neonatos e delinear o perfil dos fisioterapeutas que trabalham em unidades de terapia intensiva na cidade de São Paulo. Métodos: Estudo transversal realizado em todos os hospitais da cidade de São Paulo que tinham registro de pelo menos um leito de terapia intensiva para neonatos, segundo o Cadastro Nacional de Estabelecimentos de Saúde em 2010. Em cada unidade, foram incluídos três categorias de fisioterapeutas: um executivo, responsável pelo serviço de fisioterapia do hospital (chefe da fisioterapia); um fisioterapeuta responsável pela assistência fisioterapêutica na unidade neonatal (fisioterapeuta de referência); e um selecionado ao acaso e diretamente envolvido no cuidado ao recém-nascido (fisioterapeuta assistencial). Resultados: Dentre os 67 hospitais elegíveis para o estudo, 63 (94,0%) dispunham de um serviço de fisioterapia. Três (4,8%) desses hospitais recusaram-se a participar. Assim, foram entrevistados 60 chefes da fisioterapia, 53 fisioterapeutas de referência e 44 fisioterapeutas assistenciais. Durante os turnos diurnos, noturnos e de finais de semana/feriados, respectivamente, não havia fisioterapeutas disponíveis em 1,7%, 45,0% e 13,3% das unidades de terapia intensiva. A assistência fisioterapêutica estava disponível por 17,8±7,2 horas/dia, e cada fisioterapeuta cuidava de 9,4±2,6 neonatos durante um turno de 6 horas. A maioria dos profissionais havia concluído pelo menos um curso de especialização. Conclusão: A maioria as unidades de terapia intensiva neonatal da cidade de São Paulo tinha fisioterapeutas atuando durante o turno diurno. Entretanto, os demais turnos tinham equipes incompletas e menos de 18 horas de assistência fisioterapêutica disponível ao dia.

    Resumo em Inglês:

    Objective: To describe the characteristics of physical therapy assistance to newborns and to provide a profile of physical therapists working in intensive care units in the city of São Paulo, Brazil. Methods: This cross-sectional study was conducted in every hospital in São Paulo city that had at least one intensive care unit bed for newborns registered at the National Registry of Health Establishments in 2010. In each unit, three types of physical therapists were included: an executive who was responsible for the physical therapy service in that hospital (chief-physical therapists), a physical therapist who was responsible for the physical therapy assistance in the neonatal unit (reference-physical therapists), and a randomly selected physical therapist who was directly involved in the neonatal care (care-physical therapists). Results: Among the 67 hospitals eligible for the study, 63 (94.0%) had a physical therapy service. Of those hospitals, three (4.8%) refused to participate. Thus, 60 chief-PTs, 52 reference-physical therapists, and 44 care-physical therapists were interviewed. During day shifts, night shifts, and weekends/holidays, there were no physical therapists in 1.7%, 45.0%, and 13.3% of the intensive care units, respectively. Physical therapy assistance was available for 17.8±7.2 hours/day, and each physical therapist cared for 9.4±2.6 newborns during six working hours. Most professionals had completed at least one specialization course. Conclusion: Most neonatal intensive care units in the city of São Paulo had physical therapists working on the day shift. However, other shifts had incomplete staff with less than 18 hours of available physical therapy assistance per day.
  • Impacto do internamento em unidade de cuidados intensivos na amplitude de movimento de pacientes graves: estudo piloto Artigos Originais

    Nepomuceno Júnior, Balbino Rivail Ventura; Martinez, Bruno Prata; Gomes Neto, Mansueto

    Resumo em Português:

    Objetivo: Aferir a amplitude de movimento articular de pacientes graves durante o internamento numa unidade de cuidados intensivos. Métodos: Estudo prospectivo e longitudinal, realizado em uma unidade de cuidados intensivos de um hospital público da cidade de Salvador (BA), no período de setembro a novembro de 2010. A principal variável avaliada foi a amplitude de movimento articular passiva, por meio da goniometria dos cotovelos, joelhos e tornozelos, no momento da admissão e na alta. Todos os pacientes internados no período foram incluídos, sendo excluídos aqueles com tempo de internamento <72 horas e com reduções da amplitude de movimento articular na admissão. Resultados: A amostra foi composta por 22 indivíduos, com idade média de 53,5±17,6 anos, tempo de internamento na unidade de cuidados intensivos de 13,0±6,0 e de ventilação mecânica de 12,0±6,3 dias. O APACHE II foi 28,5±7,3, sendo que a maioria dos pacientes era independente funcional previamente ao internamento, com índice de Barthel prévio de 88,8±19. As perdas de amplitude de movimento articular foram 11,1±2,1°; 11,0±2,2°; 8,4±1,7°; 9,2±1,6°; 5,8±0,9° e 5,1±1,0°; para cotovelos, joelhos e tornozelos, respectivamente do lado direito e esquerdo (p<0,001). Conclusão: Houve uma tendência de decréscimo nas amplitudes de movimento de grandes articulações, como tornozelo, joelho e cotovelo, durante o internamento em unidade de cuidados intensivos.

    Resumo em Inglês:

    Objective: To evaluate the joint range of motion of critically ill patients during hospitalization in the intensive care unit. Methods: This work was a prospective longitudinal study conducted in a critical care unit of a public hospital in the city of Salvador (BA) from September to November 2010. The main variable evaluated was the passive joint range of motion. A goniometer was used to measure the elbows, knees and ankles at the time of admission and at discharge. All patients admitted in the period were included other than patients with length of stay <72 hours and patients with reduced joint range of motion on admission. Results: The sample consisted of 22 subjects with a mean age of 53.5±17.6 years, duration of stay in the intensive care unit of 13.0±6.0 days and time on mechanical ventilation of 12.0±6.3 days. The APACHE II score was 28.5±7.3, and the majority of patients had functional independence at admission with a prior Barthel index of 88.8±19. The losses of joint range of motion were 11.1±2.1°, 11.0±2.2°, 8.4±1.7°, 9.2±1.6°, 5.8±0.9° and 5.1±1.0°, for the right and left elbows, knees and ankles, respectively (p<0.001). Conclusion: There was a tendency towards decreased range of motion of large joints such as the ankle, knee and elbow during hospitalization in the intensive care unit.
  • Avaliação e tratamento da hiperglicemia em pacientes graves Artigo De Revisão

    Viana, Marina Verçoza; Moraes, Rafael Barberena; Fabbrin, Amanda Rodrigues; Santos, Manoella Freitas; Gerchman, Fernando

    Resumo em Português:

    A hiperglicemia é um problema frequentemente encontrado em pacientes graves em ambiente de terapia intensiva. Sua presença se associa ao aumento da morbidade e da mortalidade, independentemente da causa da admissão (infarto agudo do miocárdio, condição após cirurgia cardiovascular, acidente vascular cerebral e sepse). Entretanto, permanecem muitas dúvidas com relação à fisiopatologia e, particularmente, em relação ao tratamento da hiperglicemia no paciente graves. Na prática clínica, devem ser levados em consideração diversos aspectos para o controle desses pacientes, inclusive os alvos de glicemia, o histórico de diabetes mellitus, a via de nutrição (enteral ou parenteral) e o equipamento de monitoramento disponível, o que aumenta substancialmente a carga de trabalho dos profissionais envolvidos nesse tratamento. Esta revisão descreveu a epidemiologia, a fisiopatologia, o tratamento e o monitoramento da hiperglicemia no paciente adulto grave.

    Resumo em Inglês:

    Hyperglycemia is a commonly encountered issue in critically ill patients in the intensive care setting. The presence of hyperglycemia is associated with increased morbidity and mortality, regardless of the reason for admission (e.g., acute myocardial infarction, status post-cardiovascular surgery, stroke, sepsis). However, the pathophysiology and, in particular, the treatment of hyperglycemia in the critically ill patient remain controversial. In clinical practice, several aspects must be taken into account in the management of these patients, including blood glucose targets, history of diabetes mellitus, the route of nutrition (enteral or parenteral), and available monitoring equipment, which substantially increases the workload of providers involved in the patients' care. This review describes the epidemiology, pathophysiology, management, and monitoring of hyperglycemia in the critically ill adult patient.
Associação de Medicina Intensiva Brasileira - AMIB Rua Arminda, 93 - Vila Olímpia, CEP 04545-100 - São Paulo - SP - Brasil, Tel.: (11) 5089-2642 - São Paulo - SP - Brazil
E-mail: rbti.artigos@amib.com.br