Acessibilidade / Reportar erro

Osteosynthesis of proximal humeral end fractures with fixed angle plate and locking screws: technique and results

OBJECTIVE: Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD: Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fractures, 11 patients had three-part proximal humerus fractures, and nine patients had two-part proximal humerus fractures. Clinical evaluation was performed using the University of California at Los Angeles (UCLA) criteria. RESULTS: The mean UCLA score was 30 points (17-34). All fractures showed union. Three patients showed fracture union at varus position. The mean UCLA score for these patients was 27 points. CONCLUSION: Osteosynthesis with Philos plate provides a stable fixation method with good functional outcome.

Humeral fractures; Fracture fixation, Internal; Cohort studies; Prospective studies


Sociedade Brasileira de Ortopedia e Traumatologia Al. Lorena, 427 14º andar, 01424-000 São Paulo - SP - Brasil, Tel.: 55 11 2137-5400 - São Paulo - SP - Brazil
E-mail: rbo@sbot.org.br