Acessibilidade / Reportar erro

The Impact of Routine Transvaginal Ultrasound Measurement of the Cervical Length on the Prediction of Preterm Birth: A Retrospective Study in a Tertiary Hospital

O impacto da medição por rotina do comprimento cervical por ecografia transvaginal na predição de parto pré-termo: Um estudo retrospetivo num hospital terciário

Abstract

Pretermbirth (PTB) is a major obstetric problem associated with high rates of neonatal morbidity and mortality. The prevalence of PTB has not changed in the last decade; thus, the establishment of a screening test and effective treatment are warranted. Transvaginal ultrasoundmeasurement of the cervical length (TUCL) has been proposed as an effective method to screen pregnant women at a higher risk of experiencing PTB.

Objective

To evaluate the applicability and usefulness of second-trimester TUCL to predict PTB in a cohort of Portuguese pregnant women.

Methods

Retrospective cross-sectional cohort study including all singleton pregnant women who performed their second-trimester ultrasound (between weeks 18 and 22þ6 days) from January 2013 to October 2017 at Centro Hospitalar Universitário São João.

Results

Our cohort included 4,481 women. The prevalence of spontaneous PTB was of 4.0%, with 0.7% occurring before the 34th week of gestation. The mean TUCL was of 33.8mm,and percentiles 3, 5 and 10 corresponded toTUCLs of 25.0mm, 27.0mmand 29.0mmrespectively. The multiple logistic regression analysis, including maternal age, previous PTB and cervical surgery showed a significant negative association between TUCL and PTB, with an odds ratio (OR) of 0.92 (95% confidence interval [95%CI]: 0.90-0.95; p<0.001). The use of a TUCL of 20mm is the best cut-off, when compared with the 25-mm cut-off, improving the prediction of risk.

Conclusion

The present study showed an inverse association between TUCL and PTB, and that the inclusion of other risk factors like maternal age, previous PTB and cervical surgery can improve the screening algorithm. Furthermore, it emphasizes that the TUCL cut-off that defines short cervix can differ according to the population.

Keywords:
preterm birth; preterm birth screening; transvaginal ultrasound cervical length; cervical length cut-off

Federação Brasileira das Sociedades de Ginecologia e Obstetrícia Av. Brigadeiro Luís Antônio, 3421, sala 903 - Jardim Paulista, 01401-001 São Paulo SP - Brasil, Tel. (55 11) 5573-4919 - Rio de Janeiro - RJ - Brazil
E-mail: editorial.office@febrasgo.org.br