Acessibilidade / Reportar erro

Determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry

A method for the determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry, using the Zeeman effect background correction and the STPF conditions is proposed. The effect of iron (III) on the phosphorus signal was studied. It was verified, through the pyrolysis temperature curves, that iron (III) is an efficient chemical modifier, thermically stabilizing phosphorus up to 1400ºC. The phosphorus signal increases with the iron (III) concentration, but in the range, which corresponds to the usual concentrations of iron in the sample solutions, the increase is small. Phosphorus was determined in three standard reference materials, after its dissolution in a mixture of hydrochloric and perchloric acids in a PTFE bomb. The agreement with the certified concentration values was excellent. Iron (III) was added to the reference analytical solutions prepared in the blank of the dissolution, while the sample solutions were measured directly, since they already contained the modifier. The detection limit (k = 2) was 0.0042% of phosphorus in the steel sample.

graphite furnace atomic absorption spectrometry; steel; phosphorus


Sociedade Brasileira de Química Secretaria Executiva, Av. Prof. Lineu Prestes, 748 - bloco 3 - Superior, 05508-000 São Paulo SP - Brazil, C.P. 26.037 - 05599-970, Tel.: +55 11 3032.2299, Fax: +55 11 3814.3602 - São Paulo - SP - Brazil