An Electrochemiluminescence Biosensor for the Determination of Mercury Ion via Dual-Amplification Strategy

Abstract

A novel dual-signal amplificatory electrochemiluminescence (ECL) deoxyribonucleic acid (DNA) biosensor was designed for the determination of Hg2+. One amplification unit was gold nanoparticles (AuNPs) modified on a glassy carbon electrode, and the other was single-stranded DNA (ssDNA) (with amino at the 3’ terminal and thiol at the 5’ terminal) labeled with a carboxyl-functionalized Ru@SiO2 nanoparticles (Ru1@SiO2) as a nanoprobe. The ECL biosensor was obtained through a strong gold-sulfur bond between Au on AuNPs modified electrode and thiol in the nanoprobe. In the presence of Hg2+, the ECL signal reduced because the T-Hg2+-T existed between the ECL nanoprobe and the complementary DNA (c-DNA), which exhibited a sensing platform for the detection of Hg2+. The results revealed that the reduced ECL intensity was linearly proportional to the logarithm of the Hg2+ concentration in the range of 1.0 pmol L-1-100 nmol L-1 with limit of detection 0.02 pmol L-1. The proposed method was applied for the analysis of Hg2+ in the river water and the results were in good agreement with that obtained by atomic fluorescence spectroscopy.

Keywords:
electrochemiluminescence; Ru1@SiO2 nanoparticles; dual-amplification strategy; Hg2+


Introduction

Mercury is one of the most toxic metal pollutants in our environment. It can accumulate in ecosystems through biological cycles11 Monikh, F. A.; Karami, O.; Hosseini, M.; Karami, N.; Bastami, A. A.; Ghasemi, A. F.; Ecotoxicol. Environ. Saf. 2013, 94, 112. and pose serious problems to the immune system, nervous system, cardiovascular system and reproductive system.22 Wang, Q.; Kim, D.; Dionysiou, D. D.; Sorial, G. A.; Timberlake, D.; Environ. Pollut. 2004, 131, 323. Thus, the highly sensitive and selective determination of Hg2+ is increasingly important in the human health research.

The most traditional methods for Hg2+ detection can be realized by atomic absorption, atomic emission or atomic fluorescence spectrometry. Although these methods are highly sensitive, most of them require complex sample preparation and expensive instrumentation. Therefore, it is still necessary to study methods for Hg2+ detection with high specificity and sensitivity.

Biosensor is a kind of analytical device that converts biological signals combined with recognition molecules and target analytes into detectable signals, which is widely used in life analysis and environmental detection. It has been demonstrated that Hg2+ can specifically interact with the thymine-thymine (T-T) mismatch in deoxyribonucleic acid (DNA) duplexes to form a T-Hg2+-T complex.33 Li, L. Y.; Wen, Y. L.; Xu, L.; Xu, Q.; Song, S. P.; Zuo, X. L.; Yan, J.; Zhang, W. J.; Liu, G.; Biosens. Bioelectron. 2016, 75, 433. When other metal ions, such as Pb2+, Cu2+, Ni2+, Cd2+, Fe2+, Co2+, Zn2+ and Ca2+ are present, the stability of the T-Hg2+-T DNA duplex is not significantly affected.44 Miyake, Y.; Togashi, H.; Tashiro, M.; Yamaguchi, H.; Oda, S.; Kudo, M.; Tanaka, Y.; Kondo, Y.; Sawa, R.; Fujimoto, T.; Machinami, T.; Ono, A.; J. Am. Chem. Soc. 2006, 128, 2172. Based on this property of T-rich DNA sequences, T-Hg2+-T coordination chemistry has received extensive attention in the development of Hg2+ biosensors, using colorimetry,55 Chen, G. H.; Chen, W. Y.; Yen, Y. C.; Wang, C. W.; Chang, H. T.; Chen, C. F.; Anal. Chem. 2014, 86, 6843.

6 Shi, X.; Gao, X.; Zhang, L.; Li, Y.; Fan, L.; Yu, H. Z.; Analyst 2015, 140, 2608.

7 Deng, P. X.; Zheng, S.; Yun, W.; Zhang, W. L.; Yang, L. Z.; Spectrochim. Acta, Part A 2019, 210, 335.
-88 Yu, T.; Zhang, T. T.; Zhao, W.; Xu, J. J.; Chen, H. Y.; Talanta 2017, 165, 570. fluorescence99 Li, Z. H.; Sun, H. J.; Ma, X. Y.; Su, R. F.; Sun, R.; Yang, C. Y.; Sun, C. Y.; Anal. Chim. Acta 2020, 1099, 136.

10 Chen, T.; Tan, S.; Wei, L. I.; Anal. Sci. 2017, 33, 1333.

11 Kim, H. S.; Angupillai, S.; Jeong, Y. M.; Park, J. S.; Kim, C. H.; Son, Y. A.; Sens. Actuators, B 2017, 240, 1272.
-1212 Makam, P.; Shilpa, R.; Kandjani, A. E.; Periasamy, S. R.; Govindaraju, T.; Biosens. Bioelectron. 2018, 100, 556. and electrochemistry,1313 Hong, M. Q.; Wang, M. Y.; Wang, J.; Xu, X. Q.; Lin, Z. Y.; Biosens. Bioelectron. 2017, 94, 19.

14 He, L. L.; Cheng, L.; Lin, Y.; Cui, H. F.; Hong, N.; Peng, H.; Kong, D. R.; Chen, C. D.; Zhang, J.; Wei, G. B.; Fan, H.; J. Electroanal. Chem. 2018, 814, 161.

15 Xu, A.; Chao, L.; Xiao, H.; Sui, Y.; Liu, J.; Xie, Q.; Yao, S.; Biosens. Bioelectron. 2018, 104, 95.
-1616 Zhang, Y. Y.; Zhang, C.; Ma, R.; Du, X.; Dong, W. H.; Chen, Y.; Chen, Q.; Mater. Sci. Eng., C 2017, 75, 175. because T-T coordination has excellent selectivity to Hg2+.

Electrochemiluminescence (ECL) technology has received extensive attention for its simple instrumentation, high sensitivity, low background, and controllability of ECL reaction, and has a great application in biosensor detection. More recently, a series of ECL biosensors based on the specific binding of T-Hg2+-T principle have been used for the detection of Hg2+.1717 Cheng, L.; Wei, B. G.; He, L. L.; Mao, L.; Zhang, J.; Ceng, J. X.; Kong, D. R.; Chen, C. D.; Cui, H. F.; Hong, N.; Fan, H.; Anal. Biochem. 2017, 518, 46.

18 Huang, Y. Z.; Li, L.; Zhang, Y.; Zhang, L. N.; Ge, S. G.; Yua, J. H.; Biosens. Bioelectron. 2019, 126, 339.

19 Li, J.; Lu, L. P.; Kang, T. F.; Cheng, S. Y.; Biosens. Bioelectron. 2016, 7715, 740.

20 Wang, D. M.; Gai, Q. Q.; Huang, R. F.; Zheng, X. W.; Biosens. Bioelectron. 2017, 98, 134.

21 Huang, R. F.; Liu, H. X.; Gai, Q. Q.; Liu, G. J.; Wei, Z.; Biosens. Bioelectron. 2015, 71, 194.

22 Ma, F.; Chen, Y.; Zhu, Y. C.; Liu, J. W.; Talanta 2019, 194, 114.

23 Babamiri, B.; Salimi, A.; Hallaj, R.; Biosens. Bioelectron. 2018, 102, 328.
-2424 Tang, Y.; Li, J. J.; Guo, Q. F.; Nie, G. M.; Biosens. Bioelectron. 2019, 282, 824. With the development of nanotechnology, some nanomaterials, such as nano-TiO2,2525 Ma, X. G.; Wang, C.; Wu, F. X.; Guan, Y. R.; Xu, G. B.; Top. Curr. Chem. 2020, 378, 28. nano-Sm2O3,2626 Mesgari, F.; Beigi, S. M.; Hosseini, F. S. M.; Ganjali, M. R.; Inorg. Chem. Commun. 2019, 106, 240. polypyrrole-cerium oxide nanocomposite2727 Karimi, A.; Husain, S. W.; Hosseini, M.; Azar, P. A.; Ganjali, M. R.; Sens. Actuators, B 2018, 271, 90. and silver nanoparticle-decorated graphene dot2828 Salehnia, F.; Hosseini, M.; Ganjaliac, M. R.; Anal. Methods 2018, 10, 508. were used to improve the ECL probe sensitivity for its excellent optical and electrochemical properties. Silica nanoparticles, with a unique pore structure and good biocompatibility, have been proved to be a favorable matrix to fix high concentration of Ru(bpy)32+ (bpy = 2,2’-bipyridyl) and used as amplified ECL signal probe, which has realized the supersensitive analysis of nucleic acids,2929 Li, M.; Yang, H. M.; Yan, M. A.; Sens. Actuators, B 2014, 191, 377. proteins,3030 Chen, Z. H.; Liu, Y.; Li, J. H.; Anal. Chem. 2013, 85, 4431. and cells.3131 Huang, X.; Deng, X.; Qi, W.; Wu, D.; New J. Chem. 2018, 42, 13558. Gold nanoparticles (AuNPs) have also been widely utilized in ECL biosensors as signal-amplifying substances3232 Wang, X.; Wang, Y.; Jiang, M.; Shan, Y. Q.; Jin, X.; Gong, M.; Wang, X. N.; Anal. Biochem. 2018, 548, 15.,3333 Jiang, W. J.; Yin, H. S.; Zhou, Y. L.; Duan, J. L.; Ai, S. Y.; Sens. Actuators, B 2018, 274, 144. and carriers of proteins, such as enzymes and antibodies.3434 Cao, J. T.; Yang, J. J.; Zhao, L. Z.; Wang, Y. L.; Wang, H.; Liu, Y. M.; Ma, S. H.; Biosens. Bioelectron. 2018, 99, 92.,3535 Ma, X. X.; Fang, C.; Yan, J. L.; Zhao, Q.; Tu, Y. F.; Talanta 2018, 186, 206. Up to now, no ECL biosensors have been fabricated for Hg2+ based on Ru1@SiO2 nanoparticles as signal amplifying substance.

In this work, an ECL biosensor for Hg2+ was designed and implemented by integrating a carboxyl-functionalized Ru@SiO2 nanoparticles (Ru1@SiO2)-tagged single-stranded DNA (ssDNA) as an ECL nanoprobe. The ECL biosensor was obtained through a strong gold-sulfur bond between Au on a AuNPs-modified glassy carbon electrode and thiol in the nanoprobe. When Hg2+ was present, retained the T rich oligonucleotides (complementary DNA, c-DNA), the T-Hg2+-T hairpin structure was formed and this conformational resulted in the remarkable quencher of the ECL signal. So, the expression of Hg2+ could be evaluated by the reduced ECL signal (Figure 1). AuNPs in this work can be used for two purposes, one was to immobilize more ECL nanoprobe, and the other was to amplify the ECL signals. Meanwhile, Ru1@SiO2 nanoparticles were chosen instead of Ru(bpy)3, as Ru1@SiO2 nanoparticles can greatly improve the detection sensitivity for Hg2+.

Figure 1
The principle diagram of ECL biosensor for Hg2+.

Experimental

Reagents

Tris-(2,2’-bipyridyl)-dichlororuthenium(II) hexahydrate (Ru(bpy)3Cl2·6H2O), tripropylamine (TPA), N-1-(3-dimethylaminopropyl)-3-ethylcarbodiimide (EDC), hydroxysuccinimide (NHS), tetraethoxysilane (TEOS), vinyltriethoxysilane (VTES), Nafion, Triton X-100 and HgCl2 were obtained from Sigma-Aldrich (St. Louis, Missouri, USA). Sodium citrate, chloroauric acid, cyclohexane, n-hexanol, acetone, ethanol, potassium ferricyanide and potassium ferrocyanide were obtained from Xi’an Chemical Reagent Company (Xi’an, China). 0.1 mol L(-1) phosphate buffer saline (PBS, 0.1 mol L-1 KH2PO4/K2HPO4-0.1 mol L-1 KCl, pH 7.0) was used as washing solution. All aqueous solutions were prepared with ultrapure water (> 18.2 MΩ cm) supplied by a Milli-Q Lab system. The Hg2+ specific oligonucleotide1515 Xu, A.; Chao, L.; Xiao, H.; Sui, Y.; Liu, J.; Xie, Q.; Yao, S.; Biosens. Bioelectron. 2018, 104, 95. was synthesized by Shanghai Sangon Biotechnology Co. Ltd. (Shanghai, China). The sequences were as following: ssDNA: 5’-SH-(-CH2)6-TTGCTCTCTCGTT-(-CH2)6-NH2-3’, c-DNA: 5’-TTCGTGTGTGCTT-3’.

Apparatus

MPI-E ECL analyzer (Xi’an Remax Electronics, Xi’an, China), UV-1600PC spectrophotometer (Meipuda Instruments Co., Shanghai, China), F-4600 spectrofluorometer (Hitachi, Japan), 2100F transmission electron microscopy (Electronics Corporation, Tokyo, Japan). The three-electrode system included glassy carbon electrode (GCE, 3 mm) as the working electrode, Ag/AgCl (saturated KCl) as the reference electrode, platinum sheet as the counter electrode.

AuNPs preparation

AuNPs were prepared in accordance with previously described methods.3636 Zhang, Y. F.; Li, B. X.; Xu, C. L.; Analyst 2010, 135, 1579. First, 100 mL of 0.01% HAuCl4 was added to a conical flask, stirred, and heated to boiling. Second, 2.75 mL of 1% sodium citrate solution was introduced, and the solution was continuously stirred and boiled for 12 min. The color of the solution changed from fuchsia to wine red. Heating was stopped, and the solution was naturally cooled to room temperature. Then, the solution was stored in a brown bottle at 4 °C.

Ru1 @SiO2 nanoparticles preparation

The Ru1@SiO2 nanoparticles were prepared according to the literature reported before.3737 Jie, G. F.; Ge, J. J.; Gao, X. S.; Li, C. L.; Biosens. Bioelectron. 2018, 118, 115. Firstly, cyclohexane, Triton x-100 and 1-hexanol were mixed at a volume ratio of 4.2:1:1, together with 500 µL of ultrapure water, stirred for 30 min. Then, 50 µL of 0.01 mol L-1 Ru(bpy)32+ was added, and the pH of the solution was adjusted to neutral with NaOH. The solution was concurrently stirred for 1 h. Subsequently, polymerization was initiated, and hydrolysis was allowed by adding 90 µL of TEOS and 60 µL of NH4OH. This process was continued for 24 h. Lastly, emulsion was destroyed with acetone and centrifuged three times with ethanol and water to obtain the orange Ru@SiO2 nanoparticles.

Ru@SiO2 nanoparticles were dispersed in 1.0 mL of ethanol solution, mixed with 500 µL of VTES, and reacted under continuous stirring for 12 h. The received solution was dispersed in a mixture of 4.2 mg mL-1 NaIO4 and 0.1 mg mL-1 KMnO4 for 5 h. Lastly, the Ru1@SiO2 nanoparticles were obtained.

ECL nanoprobe preparation

Ru1@SiO2-ssDNA as an ECL probe was synthesized in accordance with a previously described method with some modifications.3838 Li, Z. J.; Qi, H. L.; Yang, H. Y.; Gao, Q.; Zhang, C. X.; Anal. Methods 2014, 6, 1317. Firstly, a newly prepared mixed solution containing 5 mg mL-1 NHS and 2 mg mL-1 EDC was added to the Ru1@SiO2 nanoparticles to activate the carboxyl groups in Ru1@SiO2 for 30 min. Secondly, the amino and thiol-binding ssDNA solution, which was prepared by dissolving 2.0 OD (optical density, about 66 µg) of ssDNA in 1.0 mL of 0.1 mol L-1 PBS (pH 7.0), was added and shaken at low speed for 24 h at room temperature. Then, 200 µL of 1.5 mol L-1 NaAc and 1.0 mL ethanol were added to the mixture above and reacted for 12 h at -20 °C in a refrigerator. Finally, the mixture was centrifuged for 30 min at 12000 r min-1 using a micro-centrifuge and the precipitate were rinsed with ethanol for three times. The dried precipitate was dissolved in 500 µL of 0.1 mol L-1 PBS (pH 7.0) and stored at -18 °C in refrigerator.

Preparation of the ECL biosensor

Before modification, the bare GCE was polished to a mirror-like surface with 0.3-0.05 µm alumina powder and thoroughly cleaned ultrasonically with ethanol and ultrapure water. Then, 0.5% Nafion solution and AuNP solution were mixed at a volume ratio of 1:2, and the mixture was ultrasonicated for 30 min. Afterward, 10 µL of the mixture solution (AuNPs with Nafion) was drop onto the surface of the pretreated GCE to form a AuNP/Nafion film-modified GCE. After the specimen was washed with water, the modified electrode was immersed in 200 µL of 1.7 µmol L-1 ECL nanoprobe for 90 min and washed with the washing buffer.

ECL measurements

The prepared ECL biosensor was immersed in 200 µL of different Hg2+ concentrations including 0.8 µmol L-1 of c-DNA for 70 min, washed with the washing buffer, and dried in air. The ECL signal was detected in 2.0 mL of 50 mmol L-1 TPA (0.1 mol L-1 PBS, pH = 7.0) at a constant potential of +1.28 V. The Hg2+ concentration was quantified in terms of a decrease in the ECL intensity by using the following formula: DIECL (DIECL = I0 − It), where I0 is the ECL intensity in the absence of Hg2+, and It is the ECL intensity in the presence of Hg2+. All experiments were conducted at room temperature (25 ± 1 °C).

Results and Discussion

Characterization of AuNPs

Transmission electron microscopy was conducted to characterize the size and morphology of AuNPs before ultrasonic treatment for 5 min. As shown in Figure 2a, the prepared AuNPs were spherical and had smooth surfaces, and their average size was about 13 nm in diameter. As illustrated in Figure 2b, the UV-Vis absorption spectra showed maximal absorption at 520 nm, and the AuNP concentration estimated through UV-Vis spectroscopy was 3.5 × 10-9 mol L-1 based on an extinction coefficient of 2.7× 108 mol L-1 cm-1 at λ = 520 nm for 13 nm particles.3636 Zhang, Y. F.; Li, B. X.; Xu, C. L.; Analyst 2010, 135, 1579.

Figure 2
TEM image (a) and UV-Vis spectra (b) of AuNPs.

Characterization of ECL nanoprobe

Figure 3A showed that the resultant Ru1@SiO2 had good dispersibility and an average diameter of about 50 nm. Figure 3B illustrated the UV-Visible spectra of Ru(bpy)32+, Ru1@SiO2, ssDNA, and Ru1@SiO2-ssDNA. The absorption spectra of the pure Ru(bpy)32+ (line a) and synthesized Ru1@SiO2 (line b) were largely similar, and two maximum absorption peaks were found at about 290 and 458 nm. A characteristic absorption peak at 260 nm was observed in the spectrum of ssDNA (line c). The Ru1@SiO2-ssDNA showed absorption peaks at 287, 457, and 246 nm (line d). In comparison with the peaks at 290 and 458 nm of Ru1@SiO2 and at 260 nm of the ssDNA, a blue shift occurred, indicating that the Ru1@SiO2-ssDNA was successfully synthesized. The UV-Visible absorption of Ru(bpy)32+ at 458 nm indicated that the concentration of the nanoprobes was estimated to be 9.2 × 10-6 mol L-1.3838 Li, Z. J.; Qi, H. L.; Yang, H. Y.; Gao, Q.; Zhang, C. X.; Anal. Methods 2014, 6, 1317. Figure 3C showed the fluorescence spectra of Ru(bpy)32+ and Ru1@SiO2-ssDNA, when the excitation wavelength was 458 nm. The maximum emission wavelength of Ru(bpy)32+ and Ru1@SiO2-ssDNA was 568 and 570 nm, respectively. This indicated the success of our nanoprobe preparation. Figure 3D presented the ECL intensity-potential curves of Ru(bpy)32+ and Ru1@SiO2-ssDNA in 50 mmol L-1 TPA (0.1 mol L-1 PBS, pH = 7.0), it can be calculated that a peak ECL intensity occurred at about 1.28 V at Ru1@SiO2-ssDNA, relative to 1.25 V of Ru(bpy)32+, there was a little shift, this indicated that the Ru1@SiO2-ssDNA could effectively do its ECL reaction, and the preparation of nanoprobe was successful.

Figure 3
(A) TEM images of Ru1@SiO2; (B) UV-Vis absorption spectra of Ru(bpy)32+ (a), Ru1@SiO2 (b), ssDNA (c) and Ru1@SiO2-ssDNA (d); (C) fluorescence spectra and (D) ECL intensity-potential profiles of Ru(bpy)32+ (a) and Ru1@SiO2-ssDNA (b).

Optimization of experimental conditions

According to the analytical principle, the experimental conditions were optimized, including the assembly time and the concentration of the ECL nanoprobe, the concentration of the c-DNA and the reaction time for T-Hg2+-T interaction.

The assembly time of the ECL nanoprobe with the AuNP was investigated (Figure 4a) after interaction with 10 pmol L-1 Hg2+. We can observe that ΔIECL increased as the assembly time was prolonged from 50 to 90 min. When the assembly time was further prolonged, ΔIECL slightly increased, indicating that the quantity of nanoprobes reached saturation. Thus, 90 min was chosen as the optimal assembly time.

Figure 4
Effect of the assembly time (a) and concentration (b) of the ECL nanoprobe, the concentration of c-DNA (c) and the reaction time for T-Hg2+-T (d) on the ECL intensity in 50 mmol L-1 TPA (0.1 mol L-1 PBS, pH = 7.0). Hg2+ in pmol L-1.

Figure 4b showed the effect of the concentration of the ECL nanoprobe on the ECL intensity. It can be seen that the ΔIECL increased with an increase of the concentration of the ECL nanoprobe from 1.0 to 1.7 µmol L-1 and then reached a plateau at 1.7 µmol L-1, which indicated that it was sufficient in the tested case. Therefore, 1.7 µmol L-1 ECL probe was employed in following experiments.

Figure 4c showed the ΔIECL increased as the concentration of c-DNA increased from 0.2 to 0.8 µmol L-1, thereafter, no obvious change has been observed in the ECL intensity after 0.8 µmol L-1. This indicates that the T-Hg2+-T reaction were complete when the concentration is 0.8 µmol L-1, so this concentration was chosen in the test.

As shown in Figure 4d, the ΔIECL increased dramatically with the increasing of the reaction time during the initial stages, and the increase was very slow after 50 min. Considering the fact that the reaction time was longer when the concentration of Hg2+ was lower. So, 70 min was chosen as the optimal reaction time for T-Hg2+-T interaction.

Performance of the biosensor for Hg2+

The ECL intensity was determined at different Hg2+ concentrations under the optimized conditions. DIECL increased as the Hg2+ concentration increased and was linearly proportional to the logarithm of the Hg2+ concentration with a linear range of 1.0 pmol L-1-100 nmol L-1 (Figure 5). The linear regression equation was ΔI = 3876.43 + 704.94 logC (nmol L-1), and the regression coefficient (R) was 0.9954. The limit of detection was defined as 0.02 pmol L-1 at a signal-to-noise ratio of 3. For comparison purposes, we summarized some biosensors previously reported for Hg2+ in Table 1. As shown in Table 1, the linear range of this method was wide and the limit of detection was lower than all the previous works.

Figure 5
ECL intensity-potential curves with different concentrations of Hg2+ at 100 mV s-1 in 50 mmol L-1 TPA (0.1 mol L-1 PBS, pH = 7.0). (a) 0, (b) 1.0 pmol L-1, (c) 10 pmol L-1, (d) 100 pmol L-1, (e) 1 nmol L-1, (f) 10 nmol L-1, (g) 100 nmol L-1. Inset: calibration curve for Hg2+.

Table 1
Detection for Hg2+ using different sensors

The reproducibility of the fabricated biosensor was measured using five individual biosensors with a standard deviation of 2.9%, and 3.3% for seven independent measurements using the same biosensor, take 10 pmol L-1 Hg2+ as a model. These results indicated that the fabricated biosensors had good reproducibility.

The storage performance of the ECL biosensor was also studied. After 1 week of storage at 4 °C in 0.1 mol L-1 PBS (pH 7.0), the average ECL value of the biosensor was 98.2% of the initial ECL value for 10 pmol L-1 Hg2+.

Interference experiments were conducted using N2+, Co2+, Cu2+, Cd2+, Pb2+, Mn2+ and Zn2+ to investigate the selectivity of the ECL biosensor (Figure 6). The results showed that Hg2+ had significant ECL strength, whereas 1000-fold of the seven other metal ions had weak emissions comparable with the blank strength. The selectivity of the biosensor was also examined in a mixture containing Hg2+ and the metal ion. The signals obtained from the mixture were similar to those obtained from the pure Hg2+ solution. These results indicated that the specificity of the biosensor for Hg2+ was high.

Figure 6
Selectivity of the ECL biosensor to 10 pmol L-1 Hg2+ by comparing it to the interfering metal ions, 10 nmol L-1 Ni2+, Co2+, Cu2+, Cd2+, Pb2+, Mn2+ and Zn2+. The black was individual metal ion alone and red was coexistence of Hg2+ and the metal ion.

The application of the ECL biosensor was also investigated. Lake water samples were collected from Danjiang River in Shangluo City of China and filtered through 0.2 µm membranes to remove impurities. The real sample was prepared by spiking different Hg2+ concentrations into lake water samples. The Hg2+ concentration was estimated with the proposed ECL biosensor, as well with the atomic fluorescent spectrometry (AFS). The experimental results are shown in Table 2. The RSD of each sample was less than 3.71% for five parallel detections, and recovery varied from 96.8% to 106.9%. The results were in good agreement with those obtained by AFS, showing the potential practicality of the biosensor for real samples.

Table 2
Recovery results of the proposed biosensors in real serum samples (n = 5)

Conclusions

A novel ECL biosensor was designed through a dual-amplification strategy to detect Hg2+. The Ru1@SiO2-ssDNA composite acted as an ECL nanoprobe, and AuNPs acted as nanocarriers to immobilize a large number of signal probes. Sensitivity could be further improved by employing the dual-amplification strategy.

This approach has been successfully applied to the monitoring of Hg2+ in river water samples. Furthermore, it could be extended to the development of other ECL and electrochemical biosensing methods for other metal ions.

Acknowledgments

This project was supported by the National Natural Science Foundation of China (No. 30970696), the Science and Technology Planning Project (2012KTDZ 02-02) and the Natural Science Basic Research Plan in ShaanXi Province of China (2018JM2040).

References

  • 1
    Monikh, F. A.; Karami, O.; Hosseini, M.; Karami, N.; Bastami, A. A.; Ghasemi, A. F.; Ecotoxicol. Environ. Saf. 2013, 94, 112.
  • 2
    Wang, Q.; Kim, D.; Dionysiou, D. D.; Sorial, G. A.; Timberlake, D.; Environ. Pollut. 2004, 131, 323.
  • 3
    Li, L. Y.; Wen, Y. L.; Xu, L.; Xu, Q.; Song, S. P.; Zuo, X. L.; Yan, J.; Zhang, W. J.; Liu, G.; Biosens. Bioelectron. 2016, 75, 433.
  • 4
    Miyake, Y.; Togashi, H.; Tashiro, M.; Yamaguchi, H.; Oda, S.; Kudo, M.; Tanaka, Y.; Kondo, Y.; Sawa, R.; Fujimoto, T.; Machinami, T.; Ono, A.; J. Am. Chem. Soc. 2006, 128, 2172.
  • 5
    Chen, G. H.; Chen, W. Y.; Yen, Y. C.; Wang, C. W.; Chang, H. T.; Chen, C. F.; Anal. Chem. 2014, 86, 6843.
  • 6
    Shi, X.; Gao, X.; Zhang, L.; Li, Y.; Fan, L.; Yu, H. Z.; Analyst 2015, 140, 2608.
  • 7
    Deng, P. X.; Zheng, S.; Yun, W.; Zhang, W. L.; Yang, L. Z.; Spectrochim. Acta, Part A 2019, 210, 335.
  • 8
    Yu, T.; Zhang, T. T.; Zhao, W.; Xu, J. J.; Chen, H. Y.; Talanta 2017, 165, 570.
  • 9
    Li, Z. H.; Sun, H. J.; Ma, X. Y.; Su, R. F.; Sun, R.; Yang, C. Y.; Sun, C. Y.; Anal. Chim. Acta 2020, 1099, 136.
  • 10
    Chen, T.; Tan, S.; Wei, L. I.; Anal. Sci. 2017, 33, 1333.
  • 11
    Kim, H. S.; Angupillai, S.; Jeong, Y. M.; Park, J. S.; Kim, C. H.; Son, Y. A.; Sens. Actuators, B 2017, 240, 1272.
  • 12
    Makam, P.; Shilpa, R.; Kandjani, A. E.; Periasamy, S. R.; Govindaraju, T.; Biosens. Bioelectron. 2018, 100, 556.
  • 13
    Hong, M. Q.; Wang, M. Y.; Wang, J.; Xu, X. Q.; Lin, Z. Y.; Biosens. Bioelectron. 2017, 94, 19.
  • 14
    He, L. L.; Cheng, L.; Lin, Y.; Cui, H. F.; Hong, N.; Peng, H.; Kong, D. R.; Chen, C. D.; Zhang, J.; Wei, G. B.; Fan, H.; J. Electroanal. Chem. 2018, 814, 161.
  • 15
    Xu, A.; Chao, L.; Xiao, H.; Sui, Y.; Liu, J.; Xie, Q.; Yao, S.; Biosens. Bioelectron. 2018, 104, 95.
  • 16
    Zhang, Y. Y.; Zhang, C.; Ma, R.; Du, X.; Dong, W. H.; Chen, Y.; Chen, Q.; Mater. Sci. Eng., C 2017, 75, 175.
  • 17
    Cheng, L.; Wei, B. G.; He, L. L.; Mao, L.; Zhang, J.; Ceng, J. X.; Kong, D. R.; Chen, C. D.; Cui, H. F.; Hong, N.; Fan, H.; Anal. Biochem. 2017, 518, 46.
  • 18
    Huang, Y. Z.; Li, L.; Zhang, Y.; Zhang, L. N.; Ge, S. G.; Yua, J. H.; Biosens. Bioelectron. 2019, 126, 339.
  • 19
    Li, J.; Lu, L. P.; Kang, T. F.; Cheng, S. Y.; Biosens. Bioelectron. 2016, 7715, 740.
  • 20
    Wang, D. M.; Gai, Q. Q.; Huang, R. F.; Zheng, X. W.; Biosens. Bioelectron. 2017, 98, 134.
  • 21
    Huang, R. F.; Liu, H. X.; Gai, Q. Q.; Liu, G. J.; Wei, Z.; Biosens. Bioelectron. 2015, 71, 194.
  • 22
    Ma, F.; Chen, Y.; Zhu, Y. C.; Liu, J. W.; Talanta 2019, 194, 114.
  • 23
    Babamiri, B.; Salimi, A.; Hallaj, R.; Biosens. Bioelectron. 2018, 102, 328.
  • 24
    Tang, Y.; Li, J. J.; Guo, Q. F.; Nie, G. M.; Biosens. Bioelectron. 2019, 282, 824.
  • 25
    Ma, X. G.; Wang, C.; Wu, F. X.; Guan, Y. R.; Xu, G. B.; Top. Curr. Chem. 2020, 378, 28.
  • 26
    Mesgari, F.; Beigi, S. M.; Hosseini, F. S. M.; Ganjali, M. R.; Inorg. Chem. Commun. 2019, 106, 240.
  • 27
    Karimi, A.; Husain, S. W.; Hosseini, M.; Azar, P. A.; Ganjali, M. R.; Sens. Actuators, B 2018, 271, 90.
  • 28
    Salehnia, F.; Hosseini, M.; Ganjaliac, M. R.; Anal. Methods 2018, 10, 508.
  • 29
    Li, M.; Yang, H. M.; Yan, M. A.; Sens. Actuators, B 2014, 191, 377.
  • 30
    Chen, Z. H.; Liu, Y.; Li, J. H.; Anal. Chem. 2013, 85, 4431.
  • 31
    Huang, X.; Deng, X.; Qi, W.; Wu, D.; New J. Chem. 2018, 42, 13558.
  • 32
    Wang, X.; Wang, Y.; Jiang, M.; Shan, Y. Q.; Jin, X.; Gong, M.; Wang, X. N.; Anal. Biochem. 2018, 548, 15.
  • 33
    Jiang, W. J.; Yin, H. S.; Zhou, Y. L.; Duan, J. L.; Ai, S. Y.; Sens. Actuators, B 2018, 274, 144.
  • 34
    Cao, J. T.; Yang, J. J.; Zhao, L. Z.; Wang, Y. L.; Wang, H.; Liu, Y. M.; Ma, S. H.; Biosens. Bioelectron. 2018, 99, 92.
  • 35
    Ma, X. X.; Fang, C.; Yan, J. L.; Zhao, Q.; Tu, Y. F.; Talanta 2018, 186, 206.
  • 36
    Zhang, Y. F.; Li, B. X.; Xu, C. L.; Analyst 2010, 135, 1579.
  • 37
    Jie, G. F.; Ge, J. J.; Gao, X. S.; Li, C. L.; Biosens. Bioelectron 2018, 118, 115.
  • 38
    Li, Z. J.; Qi, H. L.; Yang, H. Y.; Gao, Q.; Zhang, C. X.; Anal. Methods 2014, 6, 1317.

Publication Dates

  • Publication in this collection
    14 Dec 2020
  • Date of issue
    Dec 2020

History

  • Received
    21 Mar 2020
  • Accepted
    17 July 2020
Sociedade Brasileira de Química Instituto de Química - UNICAMP, Caixa Postal 6154, 13083-970 Campinas SP - Brazil, Tel./FAX.: +55 19 3521-3151 - São Paulo - SP - Brazil
E-mail: office@jbcs.sbq.org.br