Evaluation of The Three-Dimensional Endoscopy in Basic and Extended Nasal Procedures: A Clinical and Cadaveric Study

Abstract

Introduction

The three-dimensional (3D) endoscope is considered a new surgical tool used in different approaches in intranasal and anterior skull base surgical procedures. There are many advantages of 3D over two-dimensional (2D) endoscopy that have been demonstrated in clinical applications, surgical training, and different experimental studies.

Objective

To show the difference between using the 3D and 2D endoscopes during endonasal and anterior skull base surgery and its importance.

Methods

Our study is divided into two phases (clinical and cadaveric phases). In the clinical study we, have performed 52 endonasal and anterior skull base surgical procedures (26 study cases and 26 control cases). We recorded accuracy, duration, and intraoperative complication for each case. The cadaveric study was performed on three cadavers. Differences in accuracy and dissection time were recorded using 3D and 2D endoscopy for each side chosen by randomization.

Results

In the clinical study, the cases done by 3D endoscope were significantly faster and more accurate with less intraoperative complications compared with cases done using 2D endoscope. In cadaveric dissection, while using 3D endoscope, there was better depth of perception regarding the anatomical landmarks compared with 2D endoscope.

Conclusion

Three-dimensional endoscopy is an advanced instrument that allows better training for the coming generation of ear, nose, and throat surgeons. Both clinical and cadaveric studies offer a promising outcome in both endonasal and anterior skull base surgery.

Keywords
three-dimensional endoscopy; skull base surgery; endoscopic sinus surgery

Introduction

Despite advancements in new equipment and surgical instruments, it is only recently that three-dimensional (3D) endoscopes have been used in endonasal and anterior skull base surgery. Previous publications have shown the importance, advantages and limitations of 3D endoscopy either in endonasal or skull base surgical approaches.11 Brown SM, Tabaee A, Singh A, Schwartz TH, Anand VK. Three-dimensional endoscopic sinus surgery: feasibility and technical aspects. Otolaryngol Head Neck Surg 2008;138(03):400-402,22 Shah RN, Leight WD, Patel MR, et al. A controlled laboratory and clinical evaluation of a three-dimensional endoscope for endonasal sinus and skull base surgery. Am J Rhinol Allergy 2011;25 (03):141-144 The endoscopes used in the present study incorporate dual ‘chip-on-the-tip’ technology in which two video chips create two different digital images which are displayed ontoa3Dscreen. Polarizing glasses are worn to project a different image to each eye.33 Szold A. Seeing is believing: visualization systems in endoscopic surgery (video, HDTV, stereoscopy, and beyond). Surg Endosc 2005;19(05): 730-733

Extended endoscopic endonasal approaches are increasingly applied in the management of various intracranial and cranial base pathologies. On one end of the complexity spectrum, lie lesions such as pituitary adenomas and encephaloceles of the cribriform plate, which can be more easily approached through the endonasal corridor.44 Cappabianca P, Cavallo LM, Colao A, et al. Endoscopic endonasal transsphenoidal approach: outcome analysis of 100 consecutive procedures. Minim Invasive Neurosurg 2002;45(04):193-200,55 de Divitiis E, Cappabianca P, Gangemi M, Cavallo LM. The role of the endoscopic transsphenoidal approach in pediatric neurosurgery. Childs Nerv Syst 2000;16(10-11):692-696,66 Dehdashti AR, Ganna A, Karabatsou K, Gentili F. Pure endoscopic endonasal approach for pituitary adenomas: early surgical results in 200 patients and comparison with previous microsurgical series. Neurosurgery 2008;62(05):1006–1015, discussion 1015– 1017

There are many advantages of the endoscope; however, it does not achieve binocular vision. Monocular endoscopes create a 2D image during the operative view which lack the depth of perception, size orientation, and hand-to-eye coordination.77 Hofmeister J, Frank TG, Cuschieri A, Wade NJ. Perceptual aspects of two-dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems. Semin Laparosc Surg 2001;8(01):12–24,88 Taffinder N, Smith SG, Huber J, Russell RC, Darzi A. The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc 1999;13(11): 1087–1092 Human kinematic studies proved that longer movement times are required by monocularcues to estimate the distance between variable surgical landmarks.99 Tabaee A, Anand VK, Fraser JF, Brown SM, Singh A, Schwartz TH. Three-dimensional endoscopic pituitary surgery. Neurosurgery 2009; 64(5, Suppl 2)288–293, discussion 294–295

Many binocular cues are essential to gain the depth of perception like convergence, stereopsis, and vertical disparities which are the main features of the 3D technology. To achieve stereopsis, two meticulously different retinal images obtained from different angles and directions are required, and then the human cortex superimposes these two images to give stereopsis. Like the majority of stereoscopic systems that provide a 3D display of the surgical field by production of minimally different images, then displayed separately to each eye, so the two generated images are the concept of stereopsis which named the dual channel and the shutter mechanism technologies.77 Hofmeister J, Frank TG, Cuschieri A, Wade NJ. Perceptual aspects of two-dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems. Semin Laparosc Surg 2001;8(01):12–24

Patients and Methods

The present study has been performed in two phases: clinical and cadaveric parts.

Clinical Study

The clinical study was performed on patients admitted to the University Hospital during 1 calendar year. All patients gave informed consent after the nature of the research had been fully explained to them and the research was approved by the Institutional Review Board of the faculty according to the Helsinki declaration (ethical research number 0201021). We used the Karl Storz second generation 3D HD endoscope (Karl Storz GmbH & Co., Tuttlingen, Germany) that utilizes the ‘dual chip-on-the-tip’ technology with two lenses on the tip of the endoscope, Medtronic navigation system (Medtconic PLC, Minnesota, USA, Model: Stealth Station™) and Panasonic 3D polarizing glasses (Panasonic, Osaka, Japan. Model: TY-EP3D20) that filter less light than conventional polarizing glasses, so the operating room was not required to be dark. The 3D polarizing glasses fit over normal glasses worn by surgeons. This phase was performed on 52 endonasal and anterior skull base cases (26 control cases using 2D endoscope and 26 study cases using 3D endoscope (►Fig. 1). Duration of surgery, accuracy (frequency of navigation system use), intraoperative complications, and surgeon discomfort were recorded.

Fig. 1
3D intra-operative view after resection of anterior skull base tumor (double images created by the 3D endoscope).

Cadaveric Dissection Study

This study was performed on three fresh frozen cadavers (six sides in total) using Karl Storz 2nd generation 3D HD endoscope (Karl Storz GmbH 81 Co., Tuttlingen, Germany) to dissect the different anatomical landmarks and regions in advanced endonasal and anterior skull base surgery. We used this endoscope for both 2D and 3D visualization using different settings on the endoscope, and this ensured minimal influence from optical variables that could arise from using two different endoscopes, making the intervention purely 3D and thus resulting in a more controlled design. Time was recorded in each side from first touching the vestibule of the nose until completing the sphenoidotomy and entering the sphenoid sinus cavity in the cadavers (uncinectomy, middle meatal antrostomy, ethmoidectomy, and sphenoidotomy were done on each side). Also, identification of various intranasal dissection sites and anatomical landmarks were done for illustrative, educational, and training purposes (►Fig. 2).

Fig. 2
3D cadaveric view inside the sphenoid sinus after removal of bone over the pituitary gland, the planum sphenoidale, and both carotid arteries.

Results

A range of operative procedures undertaken using 2D and 3D endoscope was performed. The majority of cases in 2 two groups were pituitary adenomas, (12 cases in each group 46.2%), followed by recurrent pituitary adenomas (6 cases in each group), as shown in ►Table 1.

Table 1
Comparison between the studied groups according to the pathology of operative cases

In the clinical study, the operative time was recorded for each case starting from touching the skin of the patient until the end of each operative procedure. The mean operative time in the 2D group was 2.92 ± 1.51 hours, while in 3D it was 1.88 ± 0.65 hours. Comparing the two groups regarding the operative time, there was a highly significant increase in operative time in the 2D group compared with the 3D group (p < 0.05) as shown in ►Table 2.

Table 2
Comparison between the studied groups according to operative time

Regarding the frequency of navigation system use intra-operatively, the mean frequency of using the navigation system in the 2D group was 5.0 ± 3.31, while in the 3D group it was 2.50 ±2.04. Consequently, there was a highly significant increase in the number of navigation system utilizations in the 2D group compared with the 3D group (p < 0.05) as demonstrated in ►Table 3.

Table 3
Comparison between the studied groups according to the frequency of navigation system use

The incidence of intraoperative complications during use of the 2D endoscope was higher than intraoperative complications while using the 3D endoscope which was not statistically significant. The most common complications reported in the 2D group were cavernous bleeding in 11 cases (42.3%) followed by cerebrospinal fluid (CSF) leak in 6 patients (23.1%), while in the 3D group there were 7 cases of CSF leak (26.9%) followed by cavernous bleeding in 5 patients (19.2%).

There was no reported discomfort to the surgeon while using the 2D endoscope; however, 3 surgeons reported headache/migraine while using the 3D endoscope. This was not statistically significant (p > 0.05).

In the cadaveric study, the mean time while using 2D endoscopy was 19.67 ±1.53 minutes, while 3D endoscopy it was 21.33 ± 4.93 minutes. This did not reach statistical significance.

Discussion

Endoscopic sinus surgery (ESS) is considered the gold standard for the management of most sinus pathologies. Improvements and updates in image quality and angled scopes have resulted in advances in ESS with the expansion of use of the endoscopic approach in skull base surgical interventions.1010 Govindaraj S, Adappa ND, Kennedy DW. Endoscopic sinus surgery: evolution and technical innovations. J Laryngol Otol 2010; 124(03):242–250

The three dimensional (3D) endoscopes have been utilized for endonasal surgery, and recent publications have shown the advantages and several limitations in using 3D endoscopes in endonasal sinus surgery or skull base surgical approaches.22 Shah RN, Leight WD, Patel MR, et al. A controlled laboratory and clinical evaluation of a three-dimensional endoscope for endonasal sinus and skull base surgery. Am J Rhinol Allergy 2011;25 (03):141-144 In these reports, 3D images were reconstructed from multiple 2D images obtained using special lenses that imitate the compound eye of bees, from various angles.1111 Wasserzug O, Margalit N, Weizman N, Fliss DM, Gil Z. Utility of a three-dimensional endoscopic system in skull base surgery. Skull Base 2010;20(04):223–228 This is a different technology to the 3D HD Storz endoscopes that were used in the present study.

In our clinical study, the mean operative time in the 2D group was significantly higher than in the 3D group. This is also shown by Castelnuovo et al., who, while studying the utilization of the 3D endoscope in resection of anterior skull base malignancy, found a statistically significant reduction of both operative time and error rates by using the new stereoscopic endoscope,1212 Castelnuovo P, Battaglia P, Bignami M, et al. Endoscopic transnasal resection of anterior skull base malignancy with a novel 3D endoscope and neuronavigation. Acta Otorhinolaryngol Ital 2012;32(03):189–191 which requires the passive polarizing 3D display1313 Committee ATASGE Technology Committee. High-definition and high-magnification endoscopes. Gastrointest Endosc 2014;80 (06):919–927 compared with the 2D endoscope. Also, they recorded low1414 Albrecht T, Baumann I, Plinkert PK, Simon C, Sertel S. Three-dimensional endoscopic visualization in functional endoscopic sinus surgery. Eur Arch Otorhinolaryngol 2016;273(11): 3753–3758 or absent surgeon discomforts with the novel stereoscopic systems.1515 Cappabianca P, Cavallo LM, Esposito F, De Divitiis O, Messina A, De Divitiis E. Extended endoscopic endonasal approach to the mid-line skull base: the evolving role of transsphenoidal surgery. Adv Tech Stand Neurosurg 2008;33:151–199 Moreover Barkhoudarian et al. reported that there is strong evidence for 3D allowing a 30-minute reduction in pituitary adenoma resection operating time.1616 Barkhoudarian G, Del Carmen Becerra Romero A, Laws ER. Evaluation of the 3-dimensional endoscope in transsphenoidal surgery. Neurosurgery 2013 73(1, Suppl Operative)ons74–ons78, discussion ons78–ons79 A shorter operative time decreases the risk of postoperative complications in endoscopic pituitary surgery.1717 Daley BJ, Cecil W, Clarke PC, Cofer JB, Guillamondegui OD. How slow is too slow? Correlation of operative time to complications: an analysis from the Tennessee Surgical Quality Collaborative. J Am Coll Surg 2015;220(04):550–558

In our study, the frequency of using the surgical navigation system showed that there was a highly significant increase in the frequency of navigation system use in the 2D group more than in the 3D group. There are no similar studies in the literature to compare with our study, but these results are in line with the hypothesis that 3D endoscopy gives improved depth of perception, hence a reduction in the need of using the navigation to confirm anatomy.

In our 2D group, there was no surgeon discomfort during all operative cases, while 3 operative cases in the 3D group resulted in the surgeon reporting discomfort (-headache/migraine); there was no significant difference between the two studied groups. Other authors in clinical and experimental studies reported similar results. Moreover, a small number of surgeons in multiple studies recorded user side effects and discomforts like dizziness, eye strain, fatigue, migraine, and headaches in 3D endoscope users.1818 Botanov Y, Ilardi SS. The acute side effects of bright light therapy: a placebo-controlled investigation. PLoS One 2013;8 (09):e75893

Minimally invasive surgery is the standard of patient care in many institutions.1919 Gallagher AG, Smith CD. From the operating room of the present to the operating room of the future. Human-factors lessons learned from the minimally invasive surgery revolution. Semin Laparosc Surg 2003;10(03):127–139 However, incidents of increased complication rates among inexperienced surgeons have been reported and a detailed study of these claims demonstrates that the surgical learning curve plays a vital role in the rate of complications.2020 Dunn D, Nair R, Fowler S, McCloy R. Laparoscopic cholecystectomy in England and Wales: results of an audit by the Royal College of Surgeons of England. Ann R Coll Surg Engl 1994;76(04): 269–275

Regarding intraoperative complications, the incidence of complications in our 2D group was higher than in the 3D group; however, it was statistically not significant. The most common complications in our 2D group was cavernous bleeding in 11 cases (42.3%) followed by CSF leak in 6 patients (23.1%), while in the 3D group there were 7 cases of CSF leak (26.9%) followed by cavernous bleeding in 5 patients (19.2%).

For endoscopic pituitary surgery, the Southern Surgeons club noted that 90% of complications happened in the first 30 patients of the learning curve, with the initial risk being 10-fold of that after 50 operations.2121 Lofrese G, Vigo V, Rigante M, et al. Learning curve of endoscopic pituitary surgery: Experience of a neurosurgery/ENT collaboration. J Clin Neurosci 2018;47:299–303 They were using 2D endoscopy and several explanations were given including: loss of depth perception (stereopsis), ergonomic difficulties of using an endoscope, and issues with training.2020 Dunn D, Nair R, Fowler S, McCloy R. Laparoscopic cholecystectomy in England and Wales: results of an audit by the Royal College of Surgeons of England. Ann R Coll Surg Engl 1994;76(04): 269–275

Regarding our cadaveric study, the mean dissection time for both sides of the cadavers using the 2D endoscope was 19.67 ±1.53 minutes, while using the 3D endoscope it was 21.33 ±4.93 minutes, which was not statistically significant (p > 0.05). It is possible that if we had chosen a more complicated index longer operation to compare then we might increase the likelihood of repeating the same results as seen in the clinical study with 2D taking longer than 3D.

The cadaveric study describes only a qualitative comparison of various approaches and anatomical landmarks using 3D endoscopy as a new learning tool and technique. Future studies should focus on more detailed quantitative comparisons of field exposure and surgical limitations.

Conclusions

Three-dimensional endoscopy is an advanced instrument that allows better training for the coming generation of ear, nose, and throat surgeons. Both clinical and cadaveric studies offer a promising outcome in both endonasal and anterior skull base surgery.

Summary

  • Using the 3D endoscope in different surgical procedures in our study revealed a significantly faster than the 2D endoscope of the same operative cases.

  • In the comparison between the 2D and 3D endoscope regarding intraoperative complications, there were less intraoperative complications while using the 3D endoscope than the 2D one, but it was statistically not significant.

  • In our study, we used a new parameter to estimate the accuracy of both 3D and 2D endoscopes, which is the number of surgical navigation system use for each case to confirm the anatomy in different operative procedures, and there was a statistically significant reduction in the number of surgical navigation system use in the 3D group compared with the 2D group.

  • In the present study, we noted a statistically nonsignificant increase in surgeon discomfort while using the 3D endoscope while no surgeon discomfort was reported while using the 2D endoscope in endonasal and anterior skull base operative procedures.

  • Using the 3D endoscope in cadaveric dissection, there was improvement in depth of perception while demonstrating different anatomical landmarks compared with the 2D endoscope; this recent development holds much promise for different surgical subspecialties and training options, particularly endonasal and anterior skull base surgery.

  • Regarding the dissection time of the cadavers, we recorded a nonsignificant increase in dissection time while using the 3D endoscope compared with the 2D endoscope. Due to the limited number of cadavers, further studies should focus on the quantitative comparison.

  • Funding
    None.

References

  • 1
    Brown SM, Tabaee A, Singh A, Schwartz TH, Anand VK. Three-dimensional endoscopic sinus surgery: feasibility and technical aspects. Otolaryngol Head Neck Surg 2008;138(03):400-402
  • 2
    Shah RN, Leight WD, Patel MR, et al. A controlled laboratory and clinical evaluation of a three-dimensional endoscope for endonasal sinus and skull base surgery. Am J Rhinol Allergy 2011;25 (03):141-144
  • 3
    Szold A. Seeing is believing: visualization systems in endoscopic surgery (video, HDTV, stereoscopy, and beyond). Surg Endosc 2005;19(05): 730-733
  • 4
    Cappabianca P, Cavallo LM, Colao A, et al. Endoscopic endonasal transsphenoidal approach: outcome analysis of 100 consecutive procedures. Minim Invasive Neurosurg 2002;45(04):193-200
  • 5
    de Divitiis E, Cappabianca P, Gangemi M, Cavallo LM. The role of the endoscopic transsphenoidal approach in pediatric neurosurgery. Childs Nerv Syst 2000;16(10-11):692-696
  • 6
    Dehdashti AR, Ganna A, Karabatsou K, Gentili F. Pure endoscopic endonasal approach for pituitary adenomas: early surgical results in 200 patients and comparison with previous microsurgical series. Neurosurgery 2008;62(05):1006–1015, discussion 1015– 1017
  • 7
    Hofmeister J, Frank TG, Cuschieri A, Wade NJ. Perceptual aspects of two-dimensional and stereoscopic display techniques in endoscopic surgery: review and current problems. Semin Laparosc Surg 2001;8(01):12–24
  • 8
    Taffinder N, Smith SG, Huber J, Russell RC, Darzi A. The effect of a second-generation 3D endoscope on the laparoscopic precision of novices and experienced surgeons. Surg Endosc 1999;13(11): 1087–1092
  • 9
    Tabaee A, Anand VK, Fraser JF, Brown SM, Singh A, Schwartz TH. Three-dimensional endoscopic pituitary surgery. Neurosurgery 2009; 64(5, Suppl 2)288–293, discussion 294–295
  • 10
    Govindaraj S, Adappa ND, Kennedy DW. Endoscopic sinus surgery: evolution and technical innovations. J Laryngol Otol 2010; 124(03):242–250
  • 11
    Wasserzug O, Margalit N, Weizman N, Fliss DM, Gil Z. Utility of a three-dimensional endoscopic system in skull base surgery. Skull Base 2010;20(04):223–228
  • 12
    Castelnuovo P, Battaglia P, Bignami M, et al. Endoscopic transnasal resection of anterior skull base malignancy with a novel 3D endoscope and neuronavigation. Acta Otorhinolaryngol Ital 2012;32(03):189–191
  • 13
    Committee ATASGE Technology Committee. High-definition and high-magnification endoscopes. Gastrointest Endosc 2014;80 (06):919–927
  • 14
    Albrecht T, Baumann I, Plinkert PK, Simon C, Sertel S. Three-dimensional endoscopic visualization in functional endoscopic sinus surgery. Eur Arch Otorhinolaryngol 2016;273(11): 3753–3758
  • 15
    Cappabianca P, Cavallo LM, Esposito F, De Divitiis O, Messina A, De Divitiis E. Extended endoscopic endonasal approach to the mid-line skull base: the evolving role of transsphenoidal surgery. Adv Tech Stand Neurosurg 2008;33:151–199
  • 16
    Barkhoudarian G, Del Carmen Becerra Romero A, Laws ER. Evaluation of the 3-dimensional endoscope in transsphenoidal surgery. Neurosurgery 2013 73(1, Suppl Operative)ons74–ons78, discussion ons78–ons79
  • 17
    Daley BJ, Cecil W, Clarke PC, Cofer JB, Guillamondegui OD. How slow is too slow? Correlation of operative time to complications: an analysis from the Tennessee Surgical Quality Collaborative. J Am Coll Surg 2015;220(04):550–558
  • 18
    Botanov Y, Ilardi SS. The acute side effects of bright light therapy: a placebo-controlled investigation. PLoS One 2013;8 (09):e75893
  • 19
    Gallagher AG, Smith CD. From the operating room of the present to the operating room of the future. Human-factors lessons learned from the minimally invasive surgery revolution. Semin Laparosc Surg 2003;10(03):127–139
  • 20
    Dunn D, Nair R, Fowler S, McCloy R. Laparoscopic cholecystectomy in England and Wales: results of an audit by the Royal College of Surgeons of England. Ann R Coll Surg Engl 1994;76(04): 269–275
  • 21
    Lofrese G, Vigo V, Rigante M, et al. Learning curve of endoscopic pituitary surgery: Experience of a neurosurgery/ENT collaboration. J Clin Neurosci 2018;47:299–303

Publication Dates

  • Publication in this collection
    04 Dec 2023
  • Date of issue
    June 2023

History

  • Received
    10 Sept 2022
  • Accepted
    11 Oct 2022
  • Published
    14 Sept 2023
Fundação Otorrinolaringologia R. Teodoro Sampaio, 483, 05405-000 São Paulo/SP Brasil, Tel.: (55 11) 3068-9855, Fax: (55 11) 3079-6769 - São Paulo - SP - Brazil
E-mail: iaorl@iaorl.org