Oxidant solution generated by electrolysis from residue of water desalinators

This work carried out studies about the use of the electrolysis process to produce oxidant solutions from water desalinators wastes for water disinfection. The experiment was conducted in laboratory scale. Three oxidant solutions were generated by electrolysis from wastes of water desalinators that presented concentrations of 1.7 x 10³ mg, 5.5 x 10³ mg and 10.2 x 10³ mg of Cl-/L.The electrolysis process lasted eight hours and the following parameters were monitored every hour: pH, electrical conductivity, temperature, total chlorine. It was observed that the production of chlorine is directly related to chloride concentration; the average content of chlorine of the oxidant solutions generated from the desalinators wastes was 0.10%, 0.24% and 0.27% m/m.

Desalination; reverse osmosis; residue; electrolysis; oxidant solution; environmental impacts