Acessibilidade / Reportar erro

Nitrogen removal in combined anoxic-aerobic system with imobilized biomass

This work aims to study the performance of a combined system in the removal of organic matter and nitrogen from sanitary sewage through internal recirculation of the effluent. The bench scale reactors were: anoxic filter (32.6 L), submerged aerated biofilter (17.6 L) and secondary settler (7.2 L). The recirculation rates were 0.5; 1.5; 2.0 and 4.0 without added external-carbon or alkalising. In 4.0 recirculation rate, the organic and nitrogen loading rates applied to the system were 0.7±0.3 kg chemical oxygen demand.m-3.d-1 and 0.08±0.02 kg N-NH4 +.m-3.d-1, reaching removals of chemical oxygen demand and total nitrogen of 92±4% and 83±8%, respectively. The results show the feasibility of using recirculation of effluent, once the final concentrations of total nitrogen (12±3 mg.L-1) are below the value stipulated by CONAMA Resolution nº 430/2011.

anoxic filter; aerated submerged biofilter; nitrification; nitrification; denitrification; immobilized biomass; sanitary sewage


Associação Brasileira de Engenharia Sanitária e Ambiental - ABES Av. Beira Mar, 216 - 13º Andar - Castelo, 20021-060 Rio de Janeiro - RJ - Brasil - Rio de Janeiro - RJ - Brazil
E-mail: esa@abes-dn.org.br