Acessibilidade / Reportar erro
Dental Press Journal of Orthodontics, Volume: 28, Número: 6, Publicado: 2023
  • How does arch form and interproximal contact size affect the 3D displacements and rotations of teeth: a finite element analysis Original Article

    ÁLVAREZ, Andrea; CORREA, Santiago Alberto; BUSCHANG, Peter H.; ROLDÁN, Samuel I.

    Resumo em Português:

    RESUMO Objetivo: O objetivo deste estudo foi determinar como o formato da arcada e o tamanho do contato interproximal deslocam os dentes inferiores submetidos a um componente anterior de força (CAF). Métodos: Nove modelos de elementos finitos (MEF) da arcada inferior foram desenvolvidos utilizando o software Ansys® v. 16.0. Eles foram projetados para avaliar os efeitos de três formatos de arcada (triangular, oval e quadrado) e três tamanhos de contato interproximal (ponto a ponto, 1 mm de diâmetro e 2 mm de diâmetro). Todos os nove modelos foram submetidos a um CAF de 53,8 N (5486 gm). Foram avaliados tridimensionalmente as rotações dentárias e os deslocamentos dos dentes inferiores, do primeiro molar direito ao primeiro molar esquerdo. Resultados: A forma da arcada teve um efeito maior no movimento dos dentes do que o tamanho do contato interproximal. Arcadas triangulares e contatos ponto a ponto produziram os maiores deslocamentos e rotações dos dentes. Arcadas ovais com pontos de contato interproximal de 2 mm de largura apresentaram maior estabilidade. O primeiro pré-molar direito apresentou os maiores deslocamentos em todos os modelos. Conclusões: O formato da arcada e o tamanho do contato interproximal afetam a estabilidade dos dentes. Os dentes foram menos estáveis nas arcadas estreitas com contatos interproximais ponto a ponto, e mais estáveis nas arcadas mais largas com contatos maiores.

    Resumo em Inglês:

    ABSTRACT Objective: The objective of this study was to determine how arch form and interproximal contact size displace mandibular teeth subjected to an anterior component of force (ACF). Methods: Nine finite element models (FEM) of the mandibular arch were developed using Ansys® v. 16.0 software. They were designed to evaluate the effects of three arch forms (triangular, oval, and square) and three contact sizes (point-to-point, 1 mm diameter, and 2 mm diameter). All nine models were subjected to an ACF of 53.8 N (5486 gm). Three-dimensional tooth rotations and displacements of the mandibular teeth were evaluated, from the right first molar to the left first molar. Results: Arch form had a greater effect on tooth movements than contact size. Triangular arches and point-to-point contacts produced the greatest displacements and rotations of teeth. Oval arches with 2 mm wide interproximal contact points showed the greatest stability. The right first premolar showed the greatest displacements in all of the models. Conclusions: Arch form and contact size affect interproximal tooth stability. Teeth are least stable in narrow arches with point-to-point interproximal contacts, and most stable in wider arches with larger contacts.
  • Dentoalveolar effects of skeletally anchored extrusion arch in anterior open bite patients: A prospective clinical trial Original Article

    ELSHAL, Noheir Samir; MOHAMMAD, Mohammad Hasan; TAWFIK, Marwa Ali; FOUDA, Maher Abd El-Salam

    Resumo em Português:

    RESUMO Objetivo: O objetivo deste ensaio clínico prospectivo foi avaliar as alterações dentárias e em tecidos moles que acompanham o uso de arco de extrusão de níquel-titânio (NiTi) com ancoragem esquelético na correção da mordida aberta anterior (MAA). Material e Métodos: Participaram deste estudo 20 pacientes do sexo feminino com idade média de 16,5 ± 1,5 anos e MAA dentoalveolar (média de 2,38 ± 0,7 mm). Todos os pacientes foram tratados com arco de extrusão de NiTi 0,017×0,025” superior, com auxílio de mini-implantes inseridos entre os segundos pré-molares e primeiros molares superiores bilateralmente, para atuar como ancoragem indireta. Modelos digitais tridimensionais e radiografias cefalométricas laterais foram realizados imediatamente antes da inserção do arco de extrusão (T0) e após 10 meses (T1). Testes t para amostras pareadas foram utilizados na análise dos dados, para avaliar as alterações após o tratamento (T1-T0). Um nível de significância de p< 0,05 foi usado. Resultados: A MAA foi fechada com sucesso em todos os pacientes, com aumento de 4,35 ± 0,61 mm na sobremordida. Os incisivos superiores foram significativamente extruídos (2,52 ± 1,02 mm) e significativamente reclinados (5,78 ± 0,77°), com uma consequente diminuição na sobressaliência de 1,58 ± 0,5 mm. Foi observada intrusão significativa dos primeiros molares superiores, sem alteração na sua inclinação. O lábio superior apresentou tendência significativa de retração em relação ao plano E, e foi observado aumento significativo do ângulo nasolabial. Conclusão: O arco de extrusão de NiTi esquelético foi uma técnica eficaz no tratamento da MAA, sem efeitos adversos nos molares.

    Resumo em Inglês:

    ABSTRACT Objective: The purpose of this prospective clinical trial was to explore the dental and soft tissue changes accompanying the use of skeletally anchored nickel-titanium (NiTi) extrusion arch in the correction of anterior open bite (AOB). Material and Methods: Twenty female patients with a mean age of 16.5 ± 1.5 years and a mean dentoalveolar AOB of 2.38±0.7 mm participated in this study. All patients were treated with an maxillary 0.017×0.025-in NiTi extrusion arch, with the aid of miniscrews inserted between the maxillary second premolars and first molars bilaterally, to act as indirect anchorage. Three-dimensional digital models and lateral cephalometric radiographs were taken just before the insertion of the extrusion arch (T0) and after 10 months (T1). Paired-sample t-tests were used in analyzing the data, to evaluate the changes after treatment (T1-T0). A significance level of p < 0.05 was used. Results: AOB was successfully closed in all patients, with a 4.35 ± 0.61 mm increase in the overbite. Maxillary incisors significantly extruded (2.52 ± 1.02 mm) and significantly reclined (5.78 ± 0.77°), with a resultant decrease in the overjet of 1.58 ± 0.5mm. A significant intrusion of maxillary first molars with no change in their inclination was observed. The upper lip showed a significant retraction tendency to the E-plane, and a significant increase in the nasolabial angle was observed. Conclusion: The skeletally anchored NiTi extrusion arch was an effective technique in treating AOB, with no adverse effects on the molars.
  • Alignment efficiency and three-dimensional assessment of root resorption after alignment with conventional and copper-nickel-titanium archwires: A randomized controlled trial Original Article

    BHATIA, Navleen Kaur; CHUGH, Vinay Kumar; SHANKAR, Sam Prasanth; VINAY A.P, Ritvik; SINGH, Surjit; MOUNGKHOM, Priyawati; SARDANA, Rinkle

    Resumo em Português:

    RESUMO Objetivo: Comparar os fios de níquel-titânio (NiTi) e de cobre-níquel-titânio (CuNiTi) quanto à eficiência do alinhamento e quantidade de reabsorção radicular, após alinhamento completo dos dentes da região anterior inferior. Métodos: Neste estudo clínico randomizado, cego, paralelo, de dois braços, quarenta e quatro pacientes com má oclusão Classe I e apinhamento anterior inferior foram recrutados na clínica ortodôntica do All India Institute of Medical Sciences (Jodhpur, India). Os pacientes foram alocados aleatoriamente nos grupos NiTi e CuNiTi, na proporção de 1:1. O alinhamento foi realizado usando a sequência de fios 0,014”, 0,016”, 0,018” e 0,019” x 0,025” nos respectivos grupos, finalizando com o arco de trabalho 0,019” x 0,025” de aço inoxidável. O desfecho primário foi a eficiência do alinhamento, medida nos modelos de estudo nos tempos inicial (T0) e após um, dois, três, quatro e cinco meses (T5). O desfecho secundário foi a reabsorção radicular, medida a partir de tomografias computadorizadas realizadas em T0 e T5. ANOVA fatorial mista foi utilizada para comparar o Índice de Irregularidade de Little (IIL). Para avaliar a proporção de pacientes com alinhamento completo ao fim de cada mês, foi construída uma curva de sobrevida pelo método de Kaplan-Meier, e o tempo até o fim do tratamento foi comparado entre os grupos por meio do teste log-rank. Um teste t pareado foi utilizado para avaliar a reabsorção radicular apical externa (RRAE) dentro dos grupos, enquanto um teste t independente foi utilizado para avaliar o IIL e a RRAE entre os grupos. Resultados: Vinte e dois pacientes foram recrutados em cada grupo. Um paciente perdeu o acompanhamento no grupo CuNiTi. Não foram observadas diferenças estatisticamente significativas entre os grupos quanto à eficiência do alinhamento (p>0,05). A comparação intergrupos revelou que as alterações na RRAE medida em três dimensões não foram estatisticamente significativas (p>0,05), exceto para o incisivo central inferior direito, que apresentou aumento da RRAE no grupo NiTi (p<0,01). Conclusão: Os dois tipos de fios de alinhamento apresentaram taxa de alinhamento semelhante em todos os momentos. A medida da reabsorção radicular não diferiu entre o grupo NiTi e CuNiTi, exceto para o incisivo central inferior direito, que apresentou maior reabsorção no grupo NiTi.

    Resumo em Inglês:

    ABSTRACT Objective: To compare alignment efficiency and root resorption between nickel-titanium (NiTi) and copper-nickel-titanium (CuNiTi) archwires after complete alignment in mandibular anterior region. Methods: In this two-arm parallel single-blind randomized controlled trial, forty-four patients with Class I malocclusion with mandibular anterior crowding were recruited form orthodontic clinic of All India Institute of Medical Sciences (Jodhpur, India). Patients were randomly allocated into NiTi and CuNiTi groups, with a 1:1 allocation. Alignment was performed using 0.014-in, 0.016-in, 0.018-in, 0.019x0.025-in archwire sequence in the respective groups, which terminated in 0.019 x 0.025-in stainless-steel working archwire. The primary outcome was alignment efficiency, measured on study models from baseline (T0) to the first, second, third, fourth and fifth-month (T5). Secondary outcome was root resorption, measured from CBCT scans taken at T0 and T5. Mixed-factorial ANOVA was used to compare Little’s Irregularity Index (LII). For assessing the proportion of patients with complete alignment at the end of each month, Kaplan-Meier survival curve was built and time to treatment completion was compared between groups using log rank test. Paired t-test was used to assess external apical root resorption (EARR) within groups, whereas independent t-test was used to evaluate LII and EARR between the groups. Results: Twenty-two patients were recruited in each group. One patient was lost to follow-up in the CuNiTi group. No statistically significant differences were observed in alignment efficiency between the groups (p>0.05). Intergroup comparison revealed that the changes in root measurement in three-dimensions were not statistically significant (p>0.05), except for mandibular right central incisor, which showed increased resorption at root apex in NiTi group (p<0.01). Conclusion: The two alignment archwires showed similar rate of alignment at all time points. Root resorption measurement did not differ between the NiTi and CuNiTi groups, except for the mandibular right central incisor, which showed more resorption in NiTi group.
  • Periodontal indexes of two types of 3 x 3 retainers: 0.032-in SS V-loop versus 0.0215-in SS coaxial - a randomized crossover trial Original Article

    SAPATA, Diogo Marques; OLIVEIRA E SILVA, Cléverson de; PASCOTTO, Renata Corrêa; POLETI, Thais Maria Freire Fernandes; ARAI, Maristela Sayuri Inoue; RAMOS, Adilson Luiz

    Resumo em Português:

    RESUMO Objetivo: Este estudo cruzado e randomizado avaliou os índices periodontais de dois tipos de contenções 3x3 (uma contenção aço V-Loop de 0,032” modificada e uma contenção convencional de fio coaxial aço de 0,0215”) após colagem, por seis meses. Além disso, foram registradas a taxa de falha na colagem e um questionário sobre conforto, facilidade de limpeza e preferência geral. Material e Métodos: Foram incluídos nesse estudo 15 pacientes que usaram ambas as contenções por seis meses cada, com intervalo de quinze dias entre cada contenção fixa. Foram registrados os seguintes índices periodontais: Índice de Placa (IP), Índice de Cálculo (IC) e Índice Gengival (IG). Os pacientes responderam a um questionário para avaliar o conforto, a facilidade de limpeza e a preferência geral pelo tipo de contenção. A taxa de falha de colagem também foi avaliada. Resultados: A contenção V-Loop apresentou maior IP (p<0,05) em comparação ao fio coaxial convencional. Entretanto, IC e IG não apresentaram diferenças estatisticamente significativas entre as contenções testadas. A contenção convencional de fio coaxial 0,0215” foi escolhida como a mais confortável (p<0,05), embora não tenham sido encontradas diferenças estatisticamente significativas para todas as outras respostas do questionário. Eventos de falha de colagem foram mais observados na contenção V-Loop 3 x 3 (p<0,002) em comparação com a contenção coaxial convencional de 0,0215”. Conclusão: A contenção V-Loop apresentou maior IP (p<0,05), maior taxa de falha de colagem e foi menos confortável em comparação ao fio coaxial convencional 0,0215”.

    Resumo em Inglês:

    ABSTRACT Objective: This randomized crossover trial evaluated periodontal indexes of two types of 3 x 3 retainers (a modified 0.032-in SS V-loop retainer and a conventional 0.0215-in SS coaxial wire retainer) after bonded for six months. Also, bonded failure rate, and a questionnaire about comfort, ease of cleaning and overall preference were recorded. Material and Methods: 15 patients were enrolled in this study who used both retainers for six months each, having a 15-day wash-out interval between each bonded retainer usage. The following periodontal index were recorded: Plaque Index (PI), Calculus Index (CI) and Gingival Index (GI). Patients answered a questionnaire to assess comfort, ease of cleaning and overall retainer-type preference. Rate of bonding failure was also evaluated. Results: V-Loop retainer showed higher PI (P<0.05) as compared to conventional 0.0215-in coaxial wire retainer. However, CI and GI presented no statistically significant differences between both types of retainers. The conventional 0.0215-in coaxial wire retainer was chosen as the most comfortable (p<0.05), although no statistically significant differences were found for all other questionnaire answers. Bonding failure events were more observed in the 3x3 V-Loop retainer (p<0.002), as compared to the conventional 0.0215-in coaxial retainer. Conclusion: V-Loop retainer showed higher PI (p<0.05), higher bonding failure rate and less comfortable, as compared to conventional 0.0215-in coaxial wire.
  • Influence of risedronate on orthodontic tooth movement in rodents: a systematic review and case report Original Article

    MIRANDA, Roberta Magalhães; FERNANDES, Juliana Lourdes; SANTOS, Mariana de Souza; JÁCOME-SANTOS, Humberto; MILAGRES, Roselaine Moreira Coelho; PRETTI, Henrique; ABREU, Lucas Guimarães; MACARI, Soraia

    Resumo em Português:

    RESUMO Introdução: Os bifosfonatos têm um impacto inibitório na atividade osteoclástica, reduzindo a reabsorção óssea. No entanto, a influência do risedronato no movimento dentário não está bem definida. Objetivo: Esta revisão sistemática avaliou o efeito do uso de risedronato no movimento ortodôntico dos dentes. Um relato de caso também é apresentado. Métodos: Dois revisores independentes pesquisaram seis bases de dados (PubMed, Web of Science, Ovid, Lilacs, Scopus e Open Grey), considerando o período de abril de 2020 até junho de 2023, sem restrições de data e/ou idioma de publicação. A questão clínica focou em avaliar o movimento ortodôntico dos dentes e movimento de recidiva (resultado) em animais (população) expostos ao risedronato (exposição) em comparação com grupos de controle (comparação). Foram aplicadas as Diretrizes Preferenciais para Revisão Sistemática e Metanálise (PRISMA) e um protocolo foi registrado no PROSPERO (CRD42020168581). O risco de viés foi determinado utilizando o protocolo do Centro de Revisão Sistemática para Experimentação em Animais de Laboratório (SYRCLE). Resultados: Dois estudos em ratos e um em porquinhos-da-índia foram incluídos na revisão sistemática. Os estudos relataram uma diminuição no movimento ortodôntico dos dentes, uma redução no movimento de recidiva e um número reduzido de células positivas à fosfatase ácida tartarato-resistente (TRAP) com um número significativamente reduzido de falhas ósseas após a administração de risedronato em ratos. Um relato de caso ilustrou os efeitos da administração de risedronato em uma paciente. Conclusão: Com base na revisão sistemática, o risedronato parece interferir no movimento ortodôntico dos dentes e na recidiva devido a uma diminuição nas células de reabsorção óssea.

    Resumo em Inglês:

    ABSTRACT Introduction: Bisphosphonates have an inhibitory impact on osteoclastic activity, reducing bone resorption. However, the influence of risedronate on tooth movement is not well-defined. Objective: This systematic review assessed the effect of risedronate intake on orthodontic tooth movement. A case report was also provided. Methods: Two independent reviewers searched six databases (PubMed, Web of Science, Ovid, Lilacs, Scopus, and Open Grey). The searches were carried out in April/2020, and an update was set in place in June/2023. Therefore, the searches considered a timeline from the databases’ inception date until June/2023, with no publication date and/or language restrictions. The clinical question focused on evaluating the orthodontic tooth movement and relapse movement (Outcome) in animals (Population) exposed to risedronate (Exposure), compared to control groups (Comparison). The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) guidelines were applied, and the protocol was registered in PROSPERO (CRD42020168581). The risk of bias was determined using the Systematic Review Centre for Laboratory Animal Experimentation protocol (SYRCLE). Results: Two studies in rats and one in guinea pigs were included in the systematic review. The studies reported a decrease in orthodontic tooth movement, a reduction in the relapse movement, and a reduced number of positive tartrate-resistant acid phosphatase (TRAP) cells, with a significantly reduced number of bone gaps after the administration of risedronate in rats. A case report illustrated the effects of risedronate administration in one patient. Conclusion: Based on the systematic review, risedronate seems to impair orthodontic tooth movement and relapse due to a decrease in bone resorption cells.
  • In-vitro effect of a single application of CPP-ACP pastes and different fluoridated solutions on the prevention of dental caries around orthodontic brackets Original Article

    LEITE, Karla Lorene de França; MARTINS, Mariana Leonel; MONTEIRO, Amanda Souza Nunes; VIEIRA, Thiago Isidro; ALEXANDRIA, Adílis Kalina; ROCHA, Gustavo Miranda; FONSECA-GONÇALVES, Andréa; PITHON, Matheus Melo; CAVALCANTI, Yuri Wanderley; MAIA, Lucianne Cople

    Resumo em Português:

    RESUMO Objetivo: Avaliar in-vitro o efeito de uma aplicação única de cremes dentais de CPP-ACP e diferentes soluções fluoretadas na prevenção da cárie dentária ao redor de braquetes ortodônticos Material e Métodos: O conjunto dentes/braquetes (n=65) foi imerso em saliva artificial (1h em 37°C) randomizado e submetido a tratamento único (100µL; 1 min) de emulsão de fosfopeptídeo de caseína-fosfato de cálcio amorfo (CPP-ACP) e CPP-ACP associado ao flúor (CPP-ACPF); soluções de tetrafluoreto de titânio (TiF4) e fluoreto de sódio (NaF); e ausência de tratamento (GC). Biofilmes multiespécie (5 x 105 CFU/mL) foram formados na presença de sacarose a 2%. Após 24h, o pH e a concentração de fluoreto solúvel total (FST) foram analisados pelo meio de cultura. Foram avaliadas a presença de lesões de mancha branca (LMB), por meio da análise de macroscopia visual, e a porcentagem de perda de dureza (%PD). Também foi verificada a topografia do esmalte, usando microscopia eletrônica de varredura (MEV). Os dados foram analisados pelos testes Qui-quadrado, Kruskal-Wallis e Mann-Whitney (p < 0,05). Resultados: Os compostos contendo flúor levaram a uma redução do pH menor do que o CPP-ACP e GC (p<0,05). Houve diferença no FST entre os grupos (p <0,05), sendo TiF4> NaF > CPP-ACPF > CPP-ACP > GC. Quanto à presença de LMB e à %PD, o grupo NaF obteve os menores valores (p<0,05), enquanto TiF4 e CPP-ACPF foram semelhantes (p> 0,05). A MEV demonstrou que os grupos sem flúor tiveram uma dissolução superficial maior. Conclusão: Os grupos fluoretados, incluindo soluções e CPP-ACPF, foram mais eficazes do que o CPP-ACP sem flúor na redução da desmineralização do esmalte ao redor dos braquetes ortodônticos após uma única aplicação.

    Resumo em Inglês:

    ABSTRACT Objective: To assess the in-vitro effect of single applications of CPP-ACP pastes and different fluoridated solutions on the prevention of dental caries around orthodontic brackets. Material and Methods: Tooth/bracket sets (n=65) were immersed in artificial saliva (1h at 37ºC) and randomly subjected to single applications (100µL; 1min) of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP emulsion), CPP-ACP with fluoride (CPP-ACPF emulsion), solutions of titanium tetrafluoride (TiF4) or sodium fluoride (NaF), or no treatment (CG). Multispecies biofilm (5 x 105 CFU/mL) was formed in the presence of 2% sucrose. After 24 h, the pH and the concentration of total soluble fluoride (TSF) were analyzed by culture medium. The presence of active white spot lesions (WSL) evaluated by macroscopic examination and the percent surface mineral loss (%SML) were analyzed. Also, the topography of enamel was detected by analysis of scanning electron microscopy (SEM). The data was assessed by chi-square, Kruskal-Wallis, and Mann-Whitney tests (p < 0.05). Results: Fluoride-containing compounds led to a smaller pH reduction than did CPP-ACP and CG (p<0.05). There was difference in TSF between the groups (p<0.05), denoted as TiF4> NaF > CPP-ACPF > CPP-ACP > CG. Regarding the presence of WSL and %SML, the NaF group obtained lower values (p<0.05), while TiF4 and CPP-ACPF were similar (p>0.05). SEM demonstrated that fluoride-free groups had a larger surface dissolution. Conclusion: Fluoridated groups including solutions and CPP-ACPF were more effective than CPP-ACP in reducing enamel demineralization around orthodontic brackets after a single application.
  • Orthodontic aligners: between passion and science Special Article

    MENDES RIBEIRO, Suelly Maria; ARAGÓN, Mônica Lídia Santos de Castro; ESPINOSA, Daybelis del Socorro González; SHIBASAKI, Wendel Minoro Muniz; NORMANDO, David

    Resumo em Português:

    RESUMO Introdução: As vantagens e desvantagens do uso de alinhadores ortodônticos têm sido reportadas com base mais na experiência clínica e opinião de experts do que em evidências científicas. Outro aspecto importante é que os alinhadores estão em processo de evolução constante. Assim, torna-se importante obter evidências recentes, que abranjam as novas atualizações na tecnologia de confecção, no desenvolvimento de novos protocolos de planejamento para as movimentações, a incorporação e desenho dos attachments e o auxílio da ancoragem esquelética. Métodos: As evidências encontradas em seis bases de dados eletrônicas (CINAHL, MEDLINE, EMBASE, Psych Info, Biblioteca Cochrane e Biblioteca Joanna Briggs) serão apresentadas por meio de perguntas e respostas. Conclusões: Há evidências de que os alinhadores apresentam diferentes níveis de dificuldade para realizar cada tipo de movimento, sendo os movimentos rotacionais e verticais os mais difíceis de serem executados. Quanto à percepção da dor causada pela movimentação dentária, parece haver menos impacto no início do tratamento, mas os alinhadores produzem mais alterações fonoarticulatórias e parecem exigir mais tempo de tratamento em casos mais complexos. Não há evidência de diferença na estabilidade pós-tratamento, e os alinhadores não impedem a ocorrência de reabsorção radicular, apesar da incidência e a gravidade da reabsorção poderem ser menores, facilitam a higiene bucal, reduzindo o risco de manchas brancas, cáries e doenças periodontais. Dada a evidência conflitante, a liberação de bisfenol-A pelo alinhador não pode ser negada. É preciso encontrar soluções que reduzam o impacto ambiental do descarte dos alinhadores. Há uma necessidade urgente de ensaios clínicos randomizados bem desenhados.

    Resumo em Inglês:

    ABSTRACT Introduction: The benefits and safety of using orthodontic aligners have been reported more by clinical experience and expert opinion than by scientific evidence. Another important aspect is that aligners are constantly evolving. It is important to obtain evidence that allows for new updates in manufacturing technology, in the development of new movement planning protocols, in the incorporation and design of attachments, and in the aid of skeletal anchorage. Methods: Evidence retrieved from six electronic databases (CINAHL, MEDLINE, EMBASE, Psych Info, the Cochrane Library and the Joanna Briggs Library) is presented by means of questions and answers. Conclusions: There is evidence that the aligners presented different levels of difficulty in performing each type of movement, with rotational and vertical movements being the most difficult to perform. Regarding perception of pain due to tooth movement, it seems to have less impact at the beginning of treatment; but dealing with more phonoarticulatory changes seems to require more treatment time in more complex cases. Aligners do not prevent the occurrence of root resorption, although the incidence and severity of resorption may be reduced, making oral hygiene easier and accepting the risk of white spots, caries and periodontal disease. Given the conflicting evidence, the release of bisphenol-A from the aligner cannot be denied. Solutions must be found to reduce the environmental impact of aligners disposal. There is an urgent need for well-designed randomized controlled trials.
Dental Press International Av. Luís Teixeira Mendes, 2712 , 87015-001 - Maringá - PR, Tel: (55 44) 3033-9818 - Maringá - PR - Brazil
E-mail: artigos@dentalpress.com.br