HIGHLIGHTS
COVID-19 has been associated to Sensorineural Hearing Loss.
Cochlear implants may benefit patients with profound hearing loss post COVID-19.
Hearing rehabilitation should not be postponed in cases of deafness post COVID-19.
COVID-19 has been associated to Sensorineural Hearing Loss.
Cochlear implants may benefit patients with profound hearing loss post COVID-19.
Hearing rehabilitation should not be postponed in cases of deafness post COVID-19.
250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 3000 Hz | 4000Hz | 6000 Hz | |
---|---|---|---|---|---|---|---|
CI RE | 35 dB | 25 dB | 50 dB | 50 dB | 35 dB | 30 dB | 25 dB |
CI LE | 40 dB | 50 dB | 35 dB | 35 dB | 45 dB | 40 dB | 20 dB |
CI RE+LE | 30 dB | 35 dB | 35 dB | 30 dB | 30 dB | 30 dB | 20 dB |
Live Speech | Recorded Speech | |||||
---|---|---|---|---|---|---|
SRT | Mono | Dis | Silence | Mono | Silence | |
CI RE | 35 dB | 28% | 72% | 96% | 04% | 86% |
CI LE | 40 dB | 44% | 68% | 96% | 16% | 85.71% |
CI RE+LE | 30 dB | 64% | 88% | 96% | 16% | 100% |