Acessibilidade / Reportar erro

Hemodynamic outcome of different ventilation modes in laparoscopic surgery with exaggerated trendelenburg: a randomised controlled trial

Abstract

Purpose:

To compare hemodynamic effects of two different modes of ventilation (volumecontrolled and pressure-controlled volume guaranteed) in patients undergoing laparoscopic gynecology surgeries with exaggerated Trendelenburg position.

Methods:

Thirty patients undergoing laparoscopic gynecology operations were ventilated using either volume-controlled (Group VC) or pressure-controlled volume guaranteed mode (Group PCVG) (n = 15 for both groups). Hemodynamic variables were measured using Pressure Recording Analytical Method by radial artery cannulation in addition to peak and mean airway pressures and expired tidal volume.

Results:

The only remarkable finding was a more stable cardiac index in Group PCVG, where other hemodynamic parameters were similar. Expired tidal volume increased in Group VC while peak airway pressure was lower in Group PCVG.

Conclusion:

PCV-VG causes less hemodynamic perturbations as measured by Pressure Recording Analytical Method (PRAM) and allows better intraoperative hemodynamic control in exaggerated Trendelenburg position in laparoscopic surgery.

KEYWORDS
Laparoscopic surgery; Mechanical ventilation; Hemodynamic monitoring

Sociedade Brasileira de Anestesiologia (SBA) Rua Professor Alfredo Gomes, 36, Botafogo , cep: 22251-080 - Rio de Janeiro - RJ / Brasil , tel: +55 (21) 97977-0024 - Rio de Janeiro - RJ - Brazil
E-mail: editor.bjan@sbahq.org