Acessibilidade / Reportar erro

Performance analysis of a trickle irrigation subunit installed in an apple orchard

Studies were carried out to evaluate the "xique-xique" irrigation system of a trickle irrigated subunit. Initial results showed that the system's performance was average, any Emission Uniformity, Statistical Uniformity and Coefficient of Global Variation were 74.51, 77.69, and 22.31%, respectively. The efficiency parameters were below expectations, and values of Application Efficiency (Ae), Storage Efficiency (Se), Deep Percolation (Dp), Deficit Degree (DD) and Adequacy Degree (a) were 100, 47.83, 0, 52.17 and 0% respectively. By adopting new management procedures, it was possible to improve the system's efficiency, reaching values of 90.20, 91.68, 9.80, 8.32 and 52.87% for Ae, Se, Dp, DD and "a", respectively.

Irrigation; efficiency; uniformity


Instituto de Tecnologia do Paraná - Tecpar Rua Prof. Algacyr Munhoz Mader, 3775 - CIC, 81350-010 Curitiba PR Brazil, Tel.: +55 41 3316-3052/3054, Fax: +55 41 3346-2872 - Curitiba - PR - Brazil
E-mail: babt@tecpar.br