Acessibilidade / Reportar erro

Subjective visual vertical evaluation in normal Brazilian subjects

Otolith function can be evaluated by subjective visual vertical (SVV) that determine the capacity of a subject to judge if the objects are on vertical position with absence of any visual reference. The aim of this study was to evaluate the SVV in a sample of normal Brazilian subjects using a portable device. Measurements of SVV were performed in 160 normal subjects (aged from 16 to 85). SVV mean value was obtained after ten adjustments. SVV mean values ranged from -2.0º to +2.4º (mean=0.18º, and SD=0.77). Considering all age groups, there was no difference of SVV mean values (Kruskal-Wallis test; p=0.40), but older groups had a greater variance (Levene test; p=0.016). SVV values observed in this study are comparable to those described in previous studies. Although there was no difference in mean SVV-inclination according to age, there was a greater variance in older subjects.

vestibular system; subjective visual vertical; otolith function


Academia Brasileira de Neurologia - ABNEURO R. Vergueiro, 1353 sl.1404 - Ed. Top Towers Offices Torre Norte, 04101-000 São Paulo SP Brazil, Tel.: +55 11 5084-9463 | +55 11 5083-3876 - São Paulo - SP - Brazil
E-mail: revista.arquivos@abneuro.org