Acessibilidade / Reportar erro

Comparison of strip meniscometry and Schirmer tear test results and tear film breakup time between healthy dogs and dogs with dry eye disease

Comparação entre o teste de meniscometria em tira, o teste lacrimal de Schirmer e o tempo de ruptura do filme lacrimal em cães normais e com olho seco

ABSTRACT

Purpose:

To compare strip meniscometry and Schirmer tear test 1 results and tear film breakup time between dogs with normal eyes and dogs diagnosed with keratoconjunctivitis sicca. Methods: One-hundred fifty-six eyes of 78 dogs, 88 normal eyes, and 68 eyes diagnosed with keratoconjunctivitis sicca were included in the study. The tests were performed in the following sequence: Schirmer tear test 1 was used to allocate the dogs to the normal or keratoconjunctivitis sicca group, followed by the strip meniscometry test and tear film breakup time measurement.

Results:

The results (mean ± standard deviation) of the tests in the normal group were as follows: Schirmer tear test 1, 22.75 ± 3.88 mm/min; strip meniscometry test, 10.01 ± 2.35 mm/5 sec; and tear film breakup time, 25.82 ± 5.47 sec. In the keratoconjunctivitis sicca group, the results were as follows: Schirmer tear test 1, 6.10 ± 4.44 mm/min; strip meniscometry test, 3.03 ± 2.62 mm/5 sec; and tear film breakup time, 10.78 ± 4.23 sec. The Spearman correlation coefficient in the keratoconjunctivitis sicca group was very high, with a significant difference between the strip meniscometry test and Schirmer tear test 1 (r=0.848, p<0.001), and moderate and significant between the strip meniscometry test and tear film breakup time (r=0.773, p<0.001). The cutoff for the strip meniscometry test for keratoconjunctivitis sicca was 7.0 mm/5 sec. Keratoconjunctivitis sicca was suspected when the values were <10 mm/5 sec.

Conclusions:

This study provided strip meniscometry test values from dogs with normal eyes and eyes with keratoconjunctivitis sicca, with high sensitivity and specificity compared with those of the Schirmer tear test 1. In the future, the strip meniscometry test may be another important quantitative test and could complement the gold standard Schirmer tear test for the diagnosis of keratoconjunctivitis sicca in dogs, an excellent animal model for the study of the disease.

Keywords:
Keratoconjunctivitis sicca; Schirmer tear test; Strip meniscometry test; Tear film breakup time; Dogs

Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil
E-mail: abo@cbo.com.br