PURPOSES: To evaluate Dextran 40 10% efficacy to maintain pig eye corneal transparency in order to indicate the best method (0.9% physiological saline, Dextran 40 10% and the mixture of both at equal parts) of conservation to maintain the transparency. METHODS: Twenty pig eyes, all of them prepared with Dextran injection in the anterior chamber and soaked in this solution for 20 minutes. Four groups, each group with five eyes and kept at 6ºC in the following solutions: Group 1 (0.9% physiological saline), Group 2 (Dextran 40 10% + 0.9% physiological saline at equal parts), Group 3 (Dextran 40 10%), Group 4 (humid chamber - control group). The eyes were observed after 12, 24, 48, 56, 72 hours and then classified according to their transparency. RESULTS: Corneal transparency occurred in 100% of the eyes with Dextran solution. 0.9% physiological saline and Dextran at equal parts achieved a longer period of transparency. CONCLUSIONS: Dextran 40 10% is an efficient solution to promote corneal transparency in post mortem pig eyes. The mixture of equal parts 0.9% physiological saline and Dextran can be used to keep feasible the prepared eyes for a period as long as 72 hours.

Cornea; Corneal opacity; Dextrans; Organ preservation; Animal; Swine


Conselho Brasileiro de Oftalmologia Rua Casa do Ator, 1117 - cj.21, 04546-004 São Paulo SP Brazil, Tel: 55 11 - 3266-4000, Fax: 55 11- 3171-0953 - São Paulo - SP - Brazil